Schneider
Schneider LR2K0306 TeSys K 0.8-1.2A Thermal Overload Relay
Schneider LR2K0306 TeSys K 0.8-1.2A Thermal Overload Relay
Не удалось загрузить сведения о доступности самовывоза
Schneider Electric LR2K0306 TeSys K Thermal Overload Relay
| Specification | Verified Product Data |
|---|---|
| Manufacturer | Schneider Electric |
| Catalog Number | LR2K0306 |
| Product Family | TeSys K |
| Product Name | TeSys LRK |
| Device Short Name | LR2K |
| Product Type | Differential Thermal Overload Relay |
| Relay Application | Motor Overload Protection |
| Protection Technology | Thermal Bimetallic |
| Thermal Protection Adjustment Range | 0.8-1.2A |
| Thermal Overload Class | Class 10A (IEC 60947-4-1) |
| Phase Failure Sensitivity | Yes |
| Phase Unbalance Protection | Yes |
| Network Type | AC / DC |
| Network Frequency | Up to 400Hz |
| Product Compatibility | LC1K / LC7K / LP1K / LP4K |
| Mounting Arrangement | Under Contactor |
| Separate Mounting | Rail or Plate with Specific Accessories |
| Separate Mounting Accessory | LA7K0064 (Sold Separately) |
| Auxiliary Contact Configuration | 1NO + 1NC |
| Normally Open Contact | 97-98 NO |
| Normally Closed Contact | 95-96 NC |
| Reset Modes | Manual / Automatic |
| Reset Mode Selector | H (Manual) / A (Automatic) |
| Test Function | Red Trip Test Button |
| Stop / Manual Reset | Blue Pushbutton |
| Trip Indication | Yellow Indicator |
| Rated Insulation Voltage (Ui), IEC | 690V |
| Rated Insulation Voltage (Ui), CSA | 600V |
| Rated Impulse Withstand Voltage (Uimp) | 6kV |
| Rated Operational Voltage, Power Circuit | Up to 690V |
| Rated Operational Voltage, AC-15 Signalling | 690V AC |
| Rated Operational Voltage, DC-13 Signalling | 250V DC |
| Conventional Free Air Thermal Current (Ith) | 6A, Signalling Circuit |
| Associated Signalling Fuse | 6A gG |
| Power Dissipation per Pole | 2W |
| Terminal Connection | Screw Clamp Terminals |
| Terminal Tightening Torque | 1.3 N·m |
| Solid Conductor Capacity | 1.5-4mm² |
| Flexible Conductor Without Ferrule | 0.75-4mm² |
| Flexible Conductor With Ferrule | 0.34-2.5mm², Single Wire |
| Degree of Protection | IP2X |
| Operating Temperature Without Derating | -20°C to +55°C |
| Operating Temperature With Derating | -30°C to +60°C |
| Storage Temperature | -40°C to +70°C |
| Operating Altitude Without Derating | 2000m |
| Product Height | 58mm |
| Product Width | 45mm |
| Product Depth | 65mm |
| Product Net Weight | 0.145kg |
| Motor Protection Standard | IEC 60947-4-1 |
| Product Certifications | UL / CSA / UKCA (Manufacturer Datasheet) |
| EAN | 3389110230420 |
| Country of Manufacture | Made in Czech Republic (Photo Label) |
Product Overview
The Schneider Electric LR2K0306 is a TeSys K / TeSys LRK differential thermal overload relay designed to protect industrial motors against overload conditions and phase failure. It features an adjustable thermal protection range of 0.8-1.2A and a Class 10A tripping characteristic conforming to IEC 60947-4-1. The relay uses a thermal bimetallic protection mechanism with phase failure sensitivity and provides one normally open (1NO) and one normally closed (1NC) auxiliary contact for signalling and control functions. The device includes a manual/automatic reset selector, red trip test button, blue stop/manual reset button and yellow trip indicator. It is designed for direct mounting under compatible TeSys K contactors, including LC1K, LC7K, LP1K and LP4K families. Separate mounting is also possible with specific accessories, such as the LA7K0064 terminal block. The compact relay measures 45 x 58 x 65mm (W x H x D) and features screw clamp terminals and IP2X protection. The supplied actual product and packaging photographs confirm the exact LR2K0306 model and 0.8-1.2A current adjustment range. The thermal setting must be selected according to the motor nameplate current, and separate short-circuit protection must be provided in the motor circuit.
Key Product Features
- TeSys K Differential Thermal Overload Relay — Schneider Electric motor overload protection device for industrial control applications.
- 0.8-1.2A Adjustable Protection — Adjustable thermal current setting for motors with compatible full-load current ratings.
- Class 10A Thermal Tripping — Overload tripping characteristic conforming to IEC 60947-4-1.
- Phase Failure Sensitivity — Differential bimetallic protection against phase failure and load unbalance conditions.
- 1NO + 1NC Auxiliary Contacts — Integrated contacts for motor protection signalling and control circuits.
- Manual and Automatic Reset — Includes a selectable reset mode, trip test control and stop/manual reset button.
- TeSys K Contactor Compatibility — Suitable for direct mounting with compatible LC1K, LC7K, LP1K and LP4K contactor families.
Actual Product Verification
In Stock & Available to Order
Schneider Electric LR2K0306 is marked in stock based on the supplied inventory information. This TeSys K differential thermal overload relay is available for industrial motor protection, electrical maintenance, replacement and project sourcing inquiries. The supplied actual photographs confirm the exact LR2K0306 model and its adjustable 0.8-1.2A thermal protection range. The relay is designed for use with compatible TeSys K contactors and requires appropriate upstream short-circuit protection. Please confirm the motor nameplate current, compatible contactor, required accessories, order quantity and dispatch arrangements before completing an order.
Schneider Electric LR2K0306
Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 0.8-1.2A thermal setting range, Class 10A protection, 1NO+1NC auxiliary contacts and compatible motor starter configuration before ordering.
Request Bulk PricingLooking for other Schneider Electric industrial automation products?
Explore Schneider Electric Industrial Automation ProductsShare