Delta CMC-EIP01 EtherNet/IP Modbus TCP Communication Option Card 1-Port RJ45 10/100Mbps for C2000 CP2000 CH2000 Drives
Delta CMC-EIP01 EtherNet/IP Modbus TCP Communication Option Card 1-Port RJ45 10/100Mbps for C2000 CP2000 CH2000 Drives
受取状況を読み込めませんでした
Delta CMC-EIP01 EtherNet/IP Communication Option Card
| Specification | Product Data |
|---|---|
| Brand | Delta Electronics |
| Exact Model | CMC-EIP01 |
| Product Type | EtherNet/IP Communication Option Card for AC Drives |
| Compatible AC Drive Series | Delta C2000 / CP2000 / CH2000 |
| Additional Documented Series | C2000 Plus / CFP2000, subject to firmware compatibility |
| Primary Communication Protocol | EtherNet/IP |
| Secondary Communication Protocol | Modbus TCP |
| Network Interface | RJ45 Ethernet |
| Ethernet Port Count | 1 Port |
| Ethernet Standards | IEEE 802.3 / IEEE 802.3u |
| Transmission Speed | 10/100Mbps Auto Detection |
| Auto MDI/MDI-X | Supported |
| Recommended Ethernet Cable | Shielded Category 5e |
| Maximum Network Cable Length | 100m per Segment |
| Modbus TCP Operating Role | Slave / Server |
| Modbus TCP Concurrent Connections | 1 |
| EtherNet/IP Explicit Messaging | Class 3 Supported |
| EtherNet/IP Cyclic I/O | Supported |
| EtherNet/IP Cyclic Transport Class | Class 1 |
| EtherNet/IP Input Assembly | Instance 101 |
| EtherNet/IP Output Assembly | Instance 100 |
| EtherNet/IP Configuration Assembly | Instance 102 |
| Supported Network Services | ICMP / IP / TCP / UDP / DHCP / SMTP / HTTP |
| Web Browser Configuration | Supported |
| Online Drive Monitoring | Supported |
| DCISoft Configuration | Supported |
| SCADA / HMI Integration | Supported via Compatible Network Protocols |
| E-mail Alarm | Supported |
| IP Address Filtering | Supported |
| Remote Drive Parameter Monitoring | Supported |
| Network Drive Frequency Command | Supported with Proper Drive Configuration |
| Network Drive Run/Stop Control | Supported with Proper Drive Configuration |
| POWER Indicator | Green LED |
| LINK Indicator | Green LED |
| Internal Drive Connection | AC Motor Drive Connection Port |
| Installation | Compatible Drive Option Card Slot |
| Card Power Supply | 5VDC from Compatible Drive |
| Power Consumption | 0.8W |
| Insulation Voltage | 500VDC |
| Approximate Weight | 25g |
| Operating Temperature | −10°C to +50°C |
| Storage Temperature | −25°C to +70°C |
| Operating Humidity | Up to 90% |
| Storage Humidity | Up to 95% |
| Firmware Compatibility | Check Card and AC Drive Firmware Against Delta Application Manual |
Product Overview
The Delta CMC-EIP01 is an EtherNet/IP and Modbus TCP communication option card designed for compatible Delta AC motor drives, including the C2000, CP2000 and CH2000 Series. It provides a single RJ45 Ethernet port with 10/100Mbps auto-detection and Auto MDI/MDI-X functionality. The card supports EtherNet/IP cyclic communication and Class 3 explicit messaging, together with Modbus TCP slave communication. Browser-based configuration, DCISoft monitoring, IP address filtering and e-mail alarm functions support industrial drive networking and maintenance. The communication card uses a 5VDC supply from the compatible drive with 0.8W power consumption. Drive series, option-card mounting and firmware versions should be verified before installation.
Key Product Features
- EtherNet/IP and Modbus TCP protocols for compatible Delta AC motor drives
- Single RJ45 port with 10/100Mbps Ethernet speed and Auto MDI/MDI-X
- Compatible with documented Delta C2000, CP2000 and CH2000 drive applications
- EtherNet/IP cyclic communication and Class 3 explicit messaging with Modbus TCP slave access
- Web and DCISoft monitoring for network configuration and drive status inspection
- IP filter and e-mail alarm functions for configurable network access and event monitoring
- Drive-powered option card using 5VDC with 0.8W consumption
Actual Product Verification
In Stock & Ready to Order
Delta CMC-EIP01 is currently in stock. Actual product circuit board and packaging photos are available for buyer reference. Please confirm the exact model, compatible Delta AC motor drive series, required EtherNet/IP or Modbus TCP communication, drive firmware, option-card slot and Ethernet network configuration before ordering.
Delta CMC-EIP01
Order online or contact us for project and quantity pricing.
Request Project PricingLooking for other Delta industrial automation products?
Explore Delta Industrial Automation ProductsShare