Schneider
Schneider LR2K0307 TeSys K 1.2-1.8A Thermal Overload Relay
Schneider LR2K0307 TeSys K 1.2-1.8A Thermal Overload Relay
Couldn't load pickup availability
Schneider Electric LR2K0307 TeSys K Thermal Overload Relay
| Specification | Verified Product Data |
|---|---|
| Manufacturer | Schneider Electric |
| Catalog Number | LR2K0307 |
| Product Family | TeSys K |
| Product Name | TeSys LRK |
| Device Short Name | LR2K |
| Product Type | Differential Thermal Overload Relay |
| Relay Application | Motor Overload Protection |
| Protection Technology | Thermal Bimetallic |
| Thermal Protection Adjustment Range | 1.2-1.8A |
| Thermal Overload Class | Class 10A (IEC 60947-4-1) |
| Phase Failure Sensitivity | Yes |
| Phase Unbalance Protection | Yes |
| Network Type | AC / DC |
| Network Frequency | Up to 400Hz |
| Product Compatibility | LC1K / LC7K / LP1K / LP4K |
| Mounting Arrangement | Under Compatible Contactor |
| Separate Mounting | Rail or Plate with Specific Accessories |
| Separate Mounting Accessory | LA7K0064 (Sold Separately) |
| Auxiliary Contact Configuration | 1NO + 1NC |
| Normally Open Contact | 97-98 NO |
| Normally Closed Contact | 95-96 NC |
| Reset Modes | Manual / Automatic |
| Reset Mode Selector | H (Manual) / A (Automatic) |
| Test Function | Red Trip Test Button |
| Stop / Manual Reset | Blue Pushbutton |
| Trip Indication | Yellow Indicator |
| Rated Insulation Voltage (Ui), IEC | 690V |
| Rated Insulation Voltage (Ui), CSA | 600V |
| Rated Impulse Withstand Voltage (Uimp) | 6kV |
| Rated Operational Voltage, Power Circuit | Up to 690V |
| Rated Operational Voltage, AC-15 Signalling | 690V AC |
| Rated Operational Voltage, DC-13 Signalling | 250V DC |
| Conventional Free Air Thermal Current (Ith) | 6A, Signalling Circuit |
| Associated Signalling Fuse | 6A gG |
| Power Dissipation per Pole | 2W |
| Terminal Connection | Screw Clamp Terminals |
| Terminal Tightening Torque | 1.3 N·m |
| Solid Conductor Capacity | 1.5-4mm² |
| Flexible Conductor Without Ferrule | 0.75-4mm² |
| Flexible Conductor With Ferrule | 0.34-2.5mm², One Conductor |
| Degree of Protection | IP2X |
| Operating Temperature Without Derating | -20°C to +55°C |
| Operating Temperature With Derating | -30°C to +60°C |
| Storage Temperature | -40°C to +70°C |
| Operating Altitude Without Derating | 2000m |
| Product Height | 58mm |
| Product Width | 45mm |
| Product Depth | 65mm |
| Product Net Weight | 0.145kg |
| Motor Protection Standard | IEC 60947-4-1 |
| Product Certifications | UL / CSA / UKCA (Manufacturer Documentation) |
| EAN | 3389110230437 |
| Country of Manufacture | Made in Czech Republic (Photo Label) |
Product Overview
The Schneider Electric LR2K0307 is a TeSys K / TeSys LRK differential thermal overload relay designed to protect industrial motors against overload conditions, phase failure and current unbalance. It features an adjustable thermal protection range of 1.2-1.8A and a Class 10A tripping characteristic conforming to IEC 60947-4-1. The relay uses thermal bimetallic protection technology and provides one normally open (1NO) and one normally closed (1NC) auxiliary contact for trip signalling and control circuits. Its front panel includes a manual/automatic reset selector, red trip test button, blue stop/manual reset button and trip indicator. The LR2K0307 is designed for direct mounting under compatible TeSys K contactors, including LC1K, LC7K, LP1K and LP4K families. Separate rail or plate mounting is possible with dedicated accessories, including the LA7K0064 terminal block, which is sold separately. The compact relay measures 45 x 58 x 65mm (W x H x D) and features screw-clamp terminals and IP2X protection. The supplied product and packaging photographs confirm the LR2K0307 model and its 1.2-1.8A thermal setting range. The relay must be adjusted to the applicable motor full-load current and used with appropriate upstream short-circuit protection.
Key Product Features
- TeSys K Differential Thermal Overload Relay — Schneider Electric bimetallic motor protection device for industrial control applications.
- 1.2-1.8A Adjustable Protection — Thermal current setting range for motors with compatible full-load current ratings.
- Class 10A Thermal Tripping — Overload protection characteristic conforming to IEC 60947-4-1.
- Phase Failure Sensitivity — Differential protection against phase loss and current unbalance conditions.
- 1NO + 1NC Auxiliary Contacts — Integrated 97-98 NO and 95-96 NC contacts for motor protection signalling.
- Manual and Automatic Reset — Selectable reset operation with trip test, stop/reset control and trip indication.
- TeSys K Contactor Compatibility — Direct mounting with compatible LC1K, LC7K, LP1K and LP4K contactor families.
Actual Product Verification
In Stock & Available to Order
Schneider Electric LR2K0307 is marked in stock based on the supplied inventory information. This TeSys K differential thermal overload relay is available for industrial motor protection, electrical maintenance, replacement and project sourcing inquiries. The supplied actual photographs confirm the exact LR2K0307 model and its adjustable 1.2-1.8A thermal protection range. The relay is designed for use with compatible TeSys K contactors and requires appropriate upstream short-circuit protection. Please confirm the motor nameplate current, contactor compatibility, required mounting accessories, order quantity and dispatch arrangements before completing an order.
Schneider Electric LR2K0307
Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 1.2-1.8A thermal setting range, Class 10A protection, 1NO+1NC auxiliary contacts and compatible motor starter configuration before ordering.
Request Bulk PricingLooking for other Schneider Electric industrial automation products?
Explore Schneider Electric Industrial Automation ProductsShare