{"product_id":"schneider-nsc100s3060n-60a-mccb","title":"Schneider NSC100S3060N Osmart 60A 3P 18kA 380V Thermal Magnetic MCCB","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Schneider NSC100S3060N Osmart NSC Circuit Breaker\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      60A | 3P \/ 3D | TM60D | 18kA @ 380V AC | 15kA @ 400V AC\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#3DCD58;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Packaging Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNSC100S3060N\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOsmart NSC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNSC100S\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMolded Case Circuit Breaker (MCCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eElectrical Distribution Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFrame Rated Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current (In)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e60 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3P (Three Pole)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtected Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3D\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTrip Unit Name\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eTM60D\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTrip Unit Technology\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Functions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOverload and Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBreaking Capacity Icu @ 220\/240V AC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e25 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBreaking Capacity Icu @ 380V AC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e18 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBreaking Capacity Icu @ 400V AC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e15 kA\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eService Breaking Capacity Ratio\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIcs = 50% of Icu (NSC100S Catalog Specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V (NSC Series Catalog)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 kV (NSC Series Catalog)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBackplate\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUpper Power Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eLower Power Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Mechanism\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eManual Toggle\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eGB\/T 14048.2 \/ IEC 60947-2 Family\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePackaging Quantity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 Piece\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePackaging Barcode\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3606489430634\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric NSC100S3060N\u003c\/strong\u003e is an \u003cstrong\u003eOsmart NSC100S molded case circuit breaker (MCCB)\u003c\/strong\u003e designed for electrical distribution protection. It is a \u003cstrong\u003ethree-pole, three-protected-pole (3P\/3D)\u003c\/strong\u003e circuit breaker equipped with a \u003cstrong\u003eTM60D thermal-magnetic trip unit\u003c\/strong\u003e. The breaker has a \u003cstrong\u003e60 A rated current\u003c\/strong\u003e within a \u003cstrong\u003e100 A frame class\u003c\/strong\u003e and provides overload and short-circuit protection. Its rated ultimate short-circuit breaking capacity (Icu) depends on the circuit operating voltage: \u003cstrong\u003e25 kA at 220\/240 V AC\u003c\/strong\u003e, \u003cstrong\u003e18 kA at 380 V AC\u003c\/strong\u003e and \u003cstrong\u003e15 kA at 400 V AC\u003c\/strong\u003e, according to the supplied exact-model packaging. These values are not interchangeable and must be matched to the installation voltage and prospective fault current. The NSC100S family has a manufacturer-catalog service breaking capacity ratio of \u003cstrong\u003eIcs = 50% of Icu\u003c\/strong\u003e. The circuit breaker is designed for fixed mounting with front electrical connections. Actual photographs show an original carton marked \u003cstrong\u003eNSC100S3060N\u003c\/strong\u003e and an ABB-independent Schneider Electric breaker housing bearing \u003cstrong\u003eSchneider Electric \/ Merlin Gerin\u003c\/strong\u003e branding and NSC family information. The full unit catalog number is not clearly visible in the photographs, so exact-unit identification should be confirmed before shipment.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eOsmart NSC100S Circuit Breaker\u003c\/strong\u003e — Schneider Electric molded case circuit breaker for electrical distribution applications.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e60 A Rated Current\u003c\/strong\u003e — TM60D thermal-magnetic trip configuration in a 100 A frame class.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e3P \/ 3D Configuration\u003c\/strong\u003e — Three-pole construction with three protected poles.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e18 kA Breaking Capacity at 380 V AC\u003c\/strong\u003e — Rated Icu for the specified voltage condition.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e15 kA Breaking Capacity at 400 V AC\u003c\/strong\u003e — Separately specified ultimate breaking capacity for 400 V systems.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e25 kA Breaking Capacity at 220\/240 V AC\u003c\/strong\u003e — Ultimate short-circuit breaking capacity under the specified voltage conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eThermal-Magnetic Protection\u003c\/strong\u003e — Overload and short-circuit protective functions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFixed Installation\u003c\/strong\u003e — Backplate mounting with front electrical connections.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExact-Model Packaging Verification\u003c\/strong\u003e — Supplied carton identifies NSC100S3060N and the rated voltage-dependent breaking capacities.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual circuit breaker and carton photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton exact catalog number: \u003cstrong\u003eNSC100S3060N\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton product type: \u003cstrong\u003eThermal-Magnetic Circuit Breaker\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton current rating: \u003cstrong\u003e60 A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton pole configuration: \u003cstrong\u003e3-Pole\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton Icu at 220\/240 V AC: \u003cstrong\u003e25 kA\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton Icu at 380 V AC: \u003cstrong\u003e18 kA\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton Icu at 400 V AC: \u003cstrong\u003e15 kA\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton quantity marking: \u003cstrong\u003e1 Piece\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton barcode: \u003cstrong\u003e3606489430634\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Unit carries \u003cstrong\u003eSchneider Electric \/ Merlin Gerin\u003c\/strong\u003e branding\u003c\/div\u003e\n        \u003cdiv\u003e✓ Unit side label identifies the corresponding NSC breaker family\u003c\/div\u003e\n        \u003cdiv\u003e✓ Unit side label is shared across multiple NSC breaker configurations\u003c\/div\u003e\n        \u003cdiv\u003e✓ Full individual unit catalog number is not clearly visible in the supplied photographs\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm the exact circuit breaker, 60 A trip rating, three-pole configuration and applicable Icu before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#3DCD58;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eNSC100S3060N\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on YINGZHOU inventory information. Actual circuit breaker and packaging photographs are available for procurement verification. This \u003cstrong\u003eOsmart NSC100S thermal-magnetic MCCB\u003c\/strong\u003e is specified for \u003cstrong\u003e60 A operation\u003c\/strong\u003e with a \u003cstrong\u003e3P\/3D configuration\u003c\/strong\u003e and a \u003cstrong\u003eTM60D trip unit\u003c\/strong\u003e. Its short-circuit breaking capacity varies with the application voltage, including \u003cstrong\u003e18 kA at 380 V AC\u003c\/strong\u003e and \u003cstrong\u003e15 kA at 400 V AC\u003c\/strong\u003e. For electrical maintenance, distribution panel replacement, bulk purchasing or project sourcing, please confirm the exact unit marking, installation voltage, prospective fault current, quantity and dispatch arrangements before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSchneider NSC100S3060N\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 60A TM60D trip rating, 3P\/3D configuration, voltage-dependent breaking capacity and installation requirements before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/ru\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#3DCD58;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Schneider Electric industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/ru\/collections\/schneider\" style=\"color:#3DCD58;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Schneider Electric Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"NSC100S3060N","offer_id":58703033008431,"sku":"NSC100S3060N","price":54.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-NSC100S3060N-Osmart-60A-3P-18kA-380V-Thermal-Magnetic-MCCB.jpg?v=1792813717","url":"https:\/\/szyingzhou.com\/ru\/products\/schneider-nsc100s3060n-60a-mccb","provider":"YingZhou Automatization","version":"1.0","type":"link"}