{"product_id":"leuze-msi-trmb-01-547931-safety-relay","title":"Leuze MSI-TRMB-01 547931 Safety Relay Test Control Unit 24V DC","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #E30613;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#E30613;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Leuze MSI-TRMB-01 547931 Safety Relay\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      MSI-TRM Series | 24V DC | PL e | Category 4 | SIL 3\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF3F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#E30613;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Identification\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#FFF3F4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLeuze electronic GmbH + Co. KG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLeuze\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMSI-TRM\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMSI-TRMB-01\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Part Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e547931\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSafety Relay \/ Test Control Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEvaluation Unit for Type 4 Single-Beam Safety Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 61496\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety Category\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCategory 4, EN ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePerformance Level\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePL e, EN ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSIL 3, IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety Integrity Level Claim Limit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSILCL 3, IEC\/EN 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMTTFd\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e100 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePFHd\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2.15 × 10⁻⁹ per Hour\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMission Time\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e24V DC ±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Current Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e200 mA (Official Specification)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContinuous Current per Path\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMaximum 3A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety-Related Switching Inputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDigital Switching Inputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety-Related Switching Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety Output Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRelay, Normally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDigital Switching Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDigital Output Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePNP Transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStart \/ Restart Interlock\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRestart Modes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAutomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExternal Device Monitoring\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSupported (EDM)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePeriodic Function Test\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eResponse Time\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e130 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRegression Delay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e130 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSensor Response Time on Test Request\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.5–8.5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Count\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConnection Cross Section\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.2–1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSnap-On Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × L)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e22.5 × 99 × 114.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUnreinforced Polyamide PA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHousing Color\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eGray\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25 to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0–75%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e155 g\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMade in Germany (Product Label)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Availability\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIN STOCK\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #E30613;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eLeuze MSI-TRMB-01\u003c\/strong\u003e, manufacturer part number \u003cstrong\u003e547931\u003c\/strong\u003e, is an industrial \u003cstrong\u003esafety relay and test control unit\u003c\/strong\u003e belonging to the \u003cstrong\u003eLeuze MSI-TRM series\u003c\/strong\u003e. It is designed as an evaluation unit for compatible \u003cstrong\u003eType 4 single-beam safety devices\u003c\/strong\u003e in accordance with IEC\/EN 61496. The unit provides safety-related signal evaluation and control functions for industrial machine safeguarding applications. The \u003cstrong\u003eMSI-TRMB-01\u003c\/strong\u003e supports the evaluation of compatible optoelectronic protective devices and provides safety-related switching outputs for integration into appropriately designed machine safety circuits. Its functionality includes \u003cstrong\u003estart\/restart interlock (RES)\u003c\/strong\u003e, \u003cstrong\u003eexternal device monitoring (EDM)\u003c\/strong\u003e and \u003cstrong\u003eperiodic function testing\u003c\/strong\u003e. Automatic and manual restart configurations are supported according to the manufacturer's operating instructions. The unit has manufacturer-specified safety characteristics of \u003cstrong\u003ePerformance Level PL e\u003c\/strong\u003e and \u003cstrong\u003eCategory 4\u003c\/strong\u003e according to EN ISO 13849-1, together with \u003cstrong\u003eSIL 3\u003c\/strong\u003e according to IEC 61508 and \u003cstrong\u003eSILCL 3\u003c\/strong\u003e according to IEC\/EN 62061. These ratings describe the device's specified safety capabilities. The achieved safety level of a complete installation depends on the overall safety system design, connected devices, wiring, configuration and validation. The \u003cstrong\u003eMSI-TRMB-01\u003c\/strong\u003e operates from a \u003cstrong\u003e24V DC power supply with a tolerance of ±20%\u003c\/strong\u003e. It provides \u003cstrong\u003etwo safety-related switching inputs\u003c\/strong\u003e, \u003cstrong\u003etwo digital switching inputs\u003c\/strong\u003e, \u003cstrong\u003etwo safety-related relay outputs\u003c\/strong\u003e and \u003cstrong\u003ethree digital PNP switching outputs\u003c\/strong\u003e. The two safety-related relay outputs use normally open switching contacts. The manufacturer specifies a maximum continuous current of \u003cstrong\u003e3A per current path\u003c\/strong\u003e, subject to the applicable electrical ratings and installation requirements. The device has a specified \u003cstrong\u003eresponse time of 130 milliseconds\u003c\/strong\u003e, making it suitable for safety functions where the complete system response and stopping time have been properly evaluated. The \u003cstrong\u003eMSI-TRMB-01\u003c\/strong\u003e uses \u003cstrong\u003e16 screw-terminal connections\u003c\/strong\u003e for electrical wiring and supports conductor cross sections from \u003cstrong\u003e0.2 to 1.5 mm²\u003c\/strong\u003e. Its compact housing measures \u003cstrong\u003e22.5 × 99 × 114.1 mm\u003c\/strong\u003e and is designed for snap-on mounting in suitable industrial control cabinets. Six front-panel LED indicators provide local status information for the safety relay's inputs, outputs, power supply and fault conditions. The housing is manufactured from unreinforced polyamide PA and has an \u003cstrong\u003eIP20 protection rating\u003c\/strong\u003e. The manufacturer specifies an operating temperature range of \u003cstrong\u003e−25 to +55°C\u003c\/strong\u003e and a storage temperature range of \u003cstrong\u003e−25 to +75°C\u003c\/strong\u003e. These environmental limits should be considered when installing the unit inside an electrical enclosure. The manufacturer's official technical documentation specifies a maximum current consumption of \u003cstrong\u003e200 mA\u003c\/strong\u003e. The actual product label shows a current consumption value of 150 mA; the difference should be checked against the applicable operating conditions and documentation before installation. This exact product is identified by the model number \u003cstrong\u003eMSI-TRMB-01\u003c\/strong\u003e and manufacturer part number \u003cstrong\u003e547931\u003c\/strong\u003e. It should not be confused with other MSI-TRM variants that may use different terminal connection technologies or configurations. Actual photographs of the product front panel and identification label are available. The photographed identification label shows the model number, manufacturer information, safety classification, supply voltage, response time and \u003cstrong\u003eMade in Germany\u003c\/strong\u003e marking. The unit is intended for integration into properly engineered industrial safety systems and must be installed, wired, configured and validated by qualified personnel in accordance with the official Leuze operating instructions. Before purchasing, buyers should confirm the exact model number, manufacturer part number, required safety function, input and output configuration, supply voltage, terminal connection type and compatibility with the intended protective devices.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF3F4;border-left:8px solid #E30613;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#E30613;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eLeuze MSI-TRM Series\u003c\/strong\u003e — Industrial safety relay designed for evaluating Type 4 single-beam safety devices.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eExact Part Number 547931\u003c\/strong\u003e — MSI-TRMB-01 safety relay with screw-terminal connections.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e24V DC Power Supply\u003c\/strong\u003e — Operates with a manufacturer-specified voltage tolerance of ±20%.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003ePL e and Category 4\u003c\/strong\u003e — Device safety ratings according to EN ISO 13849-1.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSIL 3 Capability\u003c\/strong\u003e — Manufacturer-specified safety integrity level according to IEC 61508.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTwo Safety Relay Outputs\u003c\/strong\u003e — Two normally open safety-related relay switching outputs.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSafety Device Evaluation\u003c\/strong\u003e — Designed for compatible Type 4 single-beam optoelectronic protective devices.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eStart\/Restart Interlock\u003c\/strong\u003e — Supports automatic and manual restart configurations.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eExternal Device Monitoring\u003c\/strong\u003e — Supports contactor monitoring (EDM).\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003ePeriodic Function Testing\u003c\/strong\u003e — Supports periodic testing of compatible protective devices.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e130 ms Response Time\u003c\/strong\u003e — Manufacturer-specified response time.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSix LED Indicators\u003c\/strong\u003e — Provides local status indication for inputs, outputs, power and fault conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eCompact DIN-Rail Installation\u003c\/strong\u003e — 22.5 mm wide housing with snap-on mounting.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIP20 Housing Protection\u003c\/strong\u003e — Suitable for appropriately protected industrial control cabinets.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eActual Product Photography\u003c\/strong\u003e — Product front and identification label photographed for model verification.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F3CCCC;border-radius:8px;background:#FFF9F9;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#E30613;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Leuze safety relay photographed\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front-panel model identification visible\u003c\/div\u003e\n        \u003cdiv\u003e✓ Exact model MSI-TRMB-01 confirmed on product label\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer part number 547931 confirmed\u003c\/div\u003e\n        \u003cdiv\u003e✓ Leuze electronic manufacturer marking visible\u003c\/div\u003e\n        \u003cdiv\u003e✓ Test Control Unit designation confirmed\u003c\/div\u003e\n        \u003cdiv\u003e✓ 24V DC ±20% supply voltage confirmed\u003c\/div\u003e\n        \u003cdiv\u003e✓ PL e and Category 4 safety ratings confirmed\u003c\/div\u003e\n        \u003cdiv\u003e✓ SIL 3 capability verified from official manufacturer documentation\u003c\/div\u003e\n        \u003cdiv\u003e✓ 130 ms response time confirmed\u003c\/div\u003e\n        \u003cdiv\u003e✓ IP20 protection rating confirmed\u003c\/div\u003e\n        \u003cdiv\u003e✓ Six front-panel LED indicators visible\u003c\/div\u003e\n        \u003cdiv\u003e✓ Screw-terminal configuration verified from manufacturer documentation\u003c\/div\u003e\n        \u003cdiv\u003e✓ Made in Germany marking visible\u003c\/div\u003e\n        \u003cdiv\u003e✓ Year of manufacture 2026 visible on product label\u003c\/div\u003e\n        \u003cdiv\u003e✓ Official Leuze technical specifications cross-referenced\u003c\/div\u003e\n        \u003cdiv\u003eNote: The actual product label indicates 150 mA current consumption, while the official product data specifies a maximum of 200 mA. The applicable rating conditions should be confirmed before installation. Photographs do not establish electrical performance or independent authenticity certification.\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #E30613;border-left:8px solid #E30613;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#E30613;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Leuze \u003cstrong\u003eMSI-TRMB-01\u003c\/strong\u003e, manufacturer part number \u003cstrong\u003e547931\u003c\/strong\u003e, is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory information. Actual photographs of the product front panel and identification label are available for exact-model confirmation. This MSI-TRM series safety relay is designed for evaluating compatible Type 4 single-beam safety devices and supports start\/restart interlock, external device monitoring and periodic function testing. The unit operates from 24V DC ±20% and provides two safety-related relay outputs with screw-terminal connections. Please confirm the required quantity, exact model, intended safety application, electrical configuration and delivery destination before ordering. Compatibility with the complete safety system must be verified using the official Leuze documentation. Additional accessories are not confirmed as included.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#E30613;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eLeuze MSI-TRMB-01 547931\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model confirmation, industrial safety component sourcing and bulk pricing. Please confirm the required quantity, safety application, electrical configuration and delivery destination before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/ru\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#E30613;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- LEUZE BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Leuze safety relays, industrial sensors and automation components?\u003c\/p\u003e\n      \u003ca href=\"\/ru\/collections\/leuze\" style=\"color:#E30613;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Leuze Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Leuze","offers":[{"title":"MSI-TRMB-01","offer_id":58891737039151,"sku":"MSI-TRMB-01","price":275.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Leuze-MSI-TRMB-01-547931-Safety-Relay-Test-Control-Unit-24V-DC.jpg?v=1794993640","url":"https:\/\/szyingzhou.com\/ru\/products\/leuze-msi-trmb-01-547931-safety-relay","provider":"YingZhou Automatization","version":"1.0","type":"link"}