{"product_id":"abb-s202-c4-s200-miniature-circuit-breaker","title":"ABB S202-C4 S200 4A 2P C Curve 6kA 400V AC Miniature Circuit Breaker","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      ABB S202-C4 S200 Miniature Circuit Breaker\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      4A | 2 Pole | C Curve | 6kA | 400V AC\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#FF0000;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB STOTZ-KONTAKT GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eS202-C4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Order Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2CDS252001R0044\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSystem pro M compact S200\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMiniature Circuit Breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2P (Two Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Protected Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTripping Characteristic\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eC Curve\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e400 V AC (IEC\/EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e440 V AC (IEC\/EN 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Circuit Capacity (Icn)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 kA at 400V AC (IEC\/EN 60898-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUltimate Breaking Capacity (Icu) @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20 kA (IEC\/EN 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eService Breaking Capacity (Ics) @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e15 kA (IEC\/EN 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUltimate Breaking Capacity (Icu) @ 400V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 kA (IEC\/EN 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eService Breaking Capacity (Ics) @ 400V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e7.5 kA (IEC\/EN 60947-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e440 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEnergy Limiting Class\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDIN Rail (35mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Mechanism\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThermal-Magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Functions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOverload and Short Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTightening Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2.8 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (H x D x W)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e88 x 69 x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWidth in Modules\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eElectrical Endurance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMechanical Endurance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60898-1, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (actual rear marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4016779523400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB S202-C4\u003c\/strong\u003e, manufacturer order code \u003cstrong\u003e2CDS252001R0044\u003c\/strong\u003e, is a \u003cstrong\u003eSystem pro M compact S200 miniature circuit breaker\u003c\/strong\u003e designed for overload and short-circuit protection in electrical distribution circuits. This \u003cstrong\u003etwo-pole (2P) MCB\u003c\/strong\u003e has a \u003cstrong\u003e4 A rated current\u003c\/strong\u003e, \u003cstrong\u003eC-curve tripping characteristic\u003c\/strong\u003e, and a \u003cstrong\u003e400 V AC rated voltage\u003c\/strong\u003e under IEC\/EN 60898-1. Its rated short-circuit breaking capacity is \u003cstrong\u003e6 kA (Icn) at 400V AC\u003c\/strong\u003e according to IEC\/EN 60898-1. Under IEC\/EN 60947-2, the ultimate breaking capacity (Icu) is \u003cstrong\u003e10 kA at 400V AC\u003c\/strong\u003e, with a service breaking capacity (Ics) of \u003cstrong\u003e7.5 kA at 400V AC\u003c\/strong\u003e. At 230V AC, different short-circuit ratings apply. The ABB S200 series combines \u003cstrong\u003ethermal overload protection\u003c\/strong\u003e with \u003cstrong\u003eelectromagnetic short-circuit tripping\u003c\/strong\u003e. Designed for \u003cstrong\u003eDIN rail mounting\u003c\/strong\u003e, this compact circuit breaker has a \u003cstrong\u003e35 mm overall width\u003c\/strong\u003e and an \u003cstrong\u003eIP20 degree of protection\u003c\/strong\u003e. Actual front and rear product photographs identify the \u003cstrong\u003eS202-C4\u003c\/strong\u003e model and \u003cstrong\u003e2CDS252001R0044\u003c\/strong\u003e manufacturer order code.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#FF0000;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eABB S200 Circuit Breaker\u003c\/strong\u003e — System pro M compact miniature circuit breaker.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e4 A Rated Current\u003c\/strong\u003e — Two-pole MCB with both poles protected.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eC-Curve Tripping\u003c\/strong\u003e — Thermal-magnetic overload and short-circuit protection.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e6 kA Breaking Capacity\u003c\/strong\u003e — Rated Icn at 400V AC under IEC\/EN 60898-1.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e10 kA Icu at 400V AC\u003c\/strong\u003e — Ultimate breaking capacity according to IEC\/EN 60947-2.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e400 V AC Rating\u003c\/strong\u003e — Rated voltage under IEC\/EN 60898-1 for 50\/60Hz installations.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eThermal-Magnetic Protection\u003c\/strong\u003e — Separate thermal and electromagnetic tripping mechanisms.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting\u003c\/strong\u003e — Two-pole design with 35 mm overall width.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#FF0000;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual front and rear circuit breaker photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front product marking: \u003cstrong\u003eABB S202-C4\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front current and trip characteristic: \u003cstrong\u003e4 A, C Curve\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front construction: \u003cstrong\u003e2P, two mechanically linked handles\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer-confirmed breaking capacity: \u003cstrong\u003e6 kA Icn at 400V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rear manufacturer order code: \u003cstrong\u003e2CDS252001R0044\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rear EAN barcode: \u003cstrong\u003e4016779523400\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rear manufacturer marking: \u003cstrong\u003eABB STOTZ-KONTAKT GmbH\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rear marking identifies manufacture in \u003cstrong\u003eChina\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front model and rear order code match ABB manufacturer documentation\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm circuit ratings and installation requirements before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#FF0000;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003eS202-C4\u003c\/strong\u003e, order code \u003cstrong\u003e2CDS252001R0044\u003c\/strong\u003e, is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on YINGZHOU inventory information. Actual front and rear product photographs are available for exact-model verification. This is a \u003cstrong\u003e4 A, two-pole, C-curve miniature circuit breaker\u003c\/strong\u003e with a \u003cstrong\u003e6 kA rated short-circuit capacity under IEC\/EN 60898-1 at 400V AC\u003c\/strong\u003e. For industrial electrical maintenance, replacement orders, bulk purchasing or multi-brand sourcing, please confirm the rated current, pole configuration, required breaking capacity, quantity and dispatch arrangements before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eABB S202-C4\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 4A rated current, 2P C-curve configuration, 6kA breaking capacity and installation requirements before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/nl\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#FF0000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other ABB industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/nl\/collections\/abb\" style=\"color:#FF0000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore ABB Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"S202-C4","offer_id":58698192781615,"sku":"S202-C4","price":12.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-S202-C4-S200-4A-2P-C-Curve-6kA-400V-AC-Miniature-Circuit-Breaker.jpg?v=1792762658","url":"https:\/\/szyingzhou.com\/nl\/products\/abb-s202-c4-s200-miniature-circuit-breaker","provider":"YingZhou Automatization","version":"1.0","type":"link"}