{"product_id":"schneider-xpsuaf13ap-harmony-xpsu-safety-relay-module","title":"Schneider XPSUAF13AP Harmony XPSU 24V AC\/DC Cat 4 SIL 3 Safety Relay Module","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Schneider Electric XPSUAF13AP Harmony XPSU Safety Relay Module\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      24V AC\/DC | 3 NO Safety Outputs | PL e \/ Cat. 4 | SIL 3 Capability\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#3DCD58;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eXPSUAF13AP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eHarmony Safety Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eHarmony XPS Universal\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety Module Name\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eXPSUAF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSafety Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePrimary Application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEmergency Stop, Guard and Safety Sensor Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSupported Input Circuits\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNC Pair \/ Antivalent Pair \/ PNP Pair \/ OSSD Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety Level\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to PL e \/ Category 4 — ISO 13849-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFunctional Safety Level\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to SIL 3 — IEC 61508\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMachinery Safety Level\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to SILCL 3 — IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e24V AC \/ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC Supply Tolerance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−15% to +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC Supply Tolerance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC Supply Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Consumption @ 24V DC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Consumption @ 24V AC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety Inputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 × 24V DC, 5mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafety Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3 NO Relay Contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConfigurable Pulsed Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3 ON\/OFF Pulsed Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDiagnostic Output\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 Semiconductor Output — Z1, Non-Safety\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDiagnostic Output Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e24V DC, 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Modes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAutomatic \/ Manual \/ Monitored\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInput Synchronisation Time\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.5s \/ 2s \/ 4s, Configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInput Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInternal Electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Line Resistance\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e500 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-1 Relay Contact Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5A at 250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-15 Relay Contact Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3A at 250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-1 Relay Contact Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5A at 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-13 Relay Contact Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3A at 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Free Air Thermal Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e8A — Manufacturer Datasheet\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAssociated Output Fuse Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10A gG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Relay Output Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Relay Output Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e15V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Response Time on Input Open\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e250V, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4kV, Overvoltage Category II\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRemovable Screw Terminal Blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Conductor Cross-Section\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.2–2.5mm², Depending on Conductor Type\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Tightening Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.5–0.6 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e35mm Symmetrical DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e22.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e100mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e120mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.200kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHousing Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP40\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSurrounding Air Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25°C to +55°C — Device Marking\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC 60947-5-1 \/ IEC 61508 \/ ISO 13849-1 \/ IEC 62061\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTÜV \/ cULus\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIndonesia — Photographed Marking\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric XPSUAF13AP\u003c\/strong\u003e is a \u003cstrong\u003eHarmony XPS Universal safety relay module\u003c\/strong\u003e designed for monitoring industrial machinery safety circuits. This safety module supports applications including emergency-stop monitoring, protective guard monitoring, magnetic safety switches, compatible proximity sensors, PNP safety sensors, RFID safety switches and safety light curtains. The module provides \u003cstrong\u003etwo safety inputs\u003c\/strong\u003e, \u003cstrong\u003ethree normally open safety relay outputs\u003c\/strong\u003e, \u003cstrong\u003ethree configurable pulsed outputs\u003c\/strong\u003e and \u003cstrong\u003eone semiconductor diagnostic output\u003c\/strong\u003e. The diagnostic output at terminal Z1 is not intended to perform a safety function. The XPSUAF13AP operates with a \u003cstrong\u003e24V AC\/DC supply\u003c\/strong\u003e, with an AC voltage tolerance of \u003cstrong\u003e−15% to +10%\u003c\/strong\u003e and a DC voltage tolerance of \u003cstrong\u003e±20%\u003c\/strong\u003e. Power consumption is specified as \u003cstrong\u003e2W at 24V DC\u003c\/strong\u003e or \u003cstrong\u003e5VA at 24V AC, 50\/60Hz\u003c\/strong\u003e. The module supports automatic, manual and monitored start functions with compatible safety circuit configurations. When integrated into an appropriately designed, configured and validated safety system, it can support applications reaching \u003cstrong\u003ePL e \/ Category 4 according to ISO 13849-1\u003c\/strong\u003e, \u003cstrong\u003eSIL 3 according to IEC 61508\u003c\/strong\u003e and \u003cstrong\u003eSILCL 3 according to IEC 62061\u003c\/strong\u003e. The manufacturer specifies a maximum response time of \u003cstrong\u003e20ms on input opening\u003c\/strong\u003e. Its three normally open relay safety outputs are rated at \u003cstrong\u003e3A AC-15 at 250V AC\u003c\/strong\u003e and \u003cstrong\u003e3A DC-13 at 24V DC\u003c\/strong\u003e, under the applicable operating conditions. The unit incorporates removable screw terminal blocks and is designed for installation on a \u003cstrong\u003e35mm DIN rail\u003c\/strong\u003e. The housing has an \u003cstrong\u003eIP40 rating\u003c\/strong\u003e, while the terminals have an \u003cstrong\u003eIP20 rating\u003c\/strong\u003e. The compact device measures \u003cstrong\u003e22.5 × 100 × 120mm\u003c\/strong\u003e and weighs approximately \u003cstrong\u003e0.200kg\u003c\/strong\u003e. Supplied actual photographs show matching \u003cstrong\u003eXPSUAF13AP\u003c\/strong\u003e identification on the module and original packaging, along with the safety specifications and \u003cstrong\u003eMade in Indonesia\u003c\/strong\u003e markings. Appropriate risk assessment, correct wiring, configuration and validation are required before using the module in a machinery safety system.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eHarmony XPS Universal Safety Module\u003c\/strong\u003e — Schneider Electric XPSUAF13AP safety relay for industrial machinery safety monitoring.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e24V AC\/DC Power Supply\u003c\/strong\u003e — Supports 24V AC at 50\/60Hz or 24V DC within specified voltage tolerances.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eUp to PL e \/ Category 4 \/ SIL 3\u003c\/strong\u003e — Supports high-level functional safety applications when correctly integrated and validated.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e3 Normally Open Safety Outputs\u003c\/strong\u003e — Three relay safety contacts for compatible industrial safety control circuits.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eVersatile Safety Input Monitoring\u003c\/strong\u003e — Supports emergency stops, protective guards and compatible safety sensors.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eConfigurable Start and Diagnostics\u003c\/strong\u003e — Automatic, manual or monitored starting with pulsed and non-safety diagnostic outputs.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eCompact DIN Rail Design\u003c\/strong\u003e — 22.5mm-wide module with removable screw terminals and IP40 housing.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Schneider Electric safety module and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Device model: \u003cstrong\u003eXPSUAF13AP\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003eXPSUAF13AP\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Device and packaging show the same exact catalog number\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer: \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product family: \u003cstrong\u003eHarmony XPS Universal\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product type: \u003cstrong\u003eSafety Relay Module\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rated supply voltage: \u003cstrong\u003e24V AC\/DC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ AC supply frequency: \u003cstrong\u003e50\/60Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Power consumption: \u003cstrong\u003e2W DC \/ 5VA AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Safety relay outputs: \u003cstrong\u003e3 NO\u003c\/strong\u003e (Manufacturer Data)\u003c\/div\u003e\n        \u003cdiv\u003e✓ Maximum safety level: \u003cstrong\u003ePL e \/ Category 4\u003c\/strong\u003e when correctly integrated\u003c\/div\u003e\n        \u003cdiv\u003e✓ Maximum functional safety level: \u003cstrong\u003eSIL 3\u003c\/strong\u003e when correctly integrated\u003c\/div\u003e\n        \u003cdiv\u003e✓ Response time: \u003cstrong\u003e≤20ms\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ AC-15 output rating: \u003cstrong\u003e3A at 250V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ DC-13 output rating: \u003cstrong\u003e3A at 24V DC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Housing protection: \u003cstrong\u003eIP40\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Terminal protection: \u003cstrong\u003eIP20\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Removable screw terminal connection confirmed by manufacturer\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer-rated dimensions: \u003cstrong\u003e22.5 × 100 × 120mm\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging quantity marking: \u003cstrong\u003ex1\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Device manufacturing mark: \u003cstrong\u003eMade in Indonesia\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging manufacturing mark: \u003cstrong\u003eMade in Indonesia\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Exact-model Schneider Electric technical datasheet available\u003c\/div\u003e\n        \u003cdiv\u003e✓ Electrical operation and safety function commissioning tests have not been provided\u003c\/div\u003e\n        \u003cdiv\u003e✓ Verify complete safety circuit, wiring and application requirements before installation\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#3DCD58;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eXPSUAF13AP\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory information. This Harmony XPS Universal safety relay module is offered for industrial machinery safety control, maintenance replacement and compatible safety circuit applications. The supplied photographs show the exact XPSUAF13AP catalog number on the product and packaging, including its \u003cstrong\u003e24V AC\/DC power supply\u003c\/strong\u003e, safety markings and \u003cstrong\u003eMade in Indonesia\u003c\/strong\u003e identification. The module provides \u003cstrong\u003ethree normally open safety relay outputs\u003c\/strong\u003e and supports applications involving emergency stop monitoring, protective guards and compatible safety sensors. The manufacturer specifies a maximum safety capability of \u003cstrong\u003ePL e \/ Category 4 \/ SIL 3\u003c\/strong\u003e, subject to the complete safety system design and validation. Please confirm the exact catalog number, safety input type, supply voltage, start function, relay output requirements and installation conditions before ordering. Functional testing and complete machinery safety validation must be performed as appropriate for the intended application.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSchneider XPSUAF13AP\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and industrial safety component sourcing. Please confirm the 24V AC\/DC supply, required safety inputs, three normally open relay safety outputs and installation requirements before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/ko\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#3DCD58;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Schneider Electric industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/ko\/collections\/schneider\" style=\"color:#3DCD58;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Schneider Electric Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"XPSUAF13AP","offer_id":59025916559663,"sku":"XPSUAF13AP","price":101.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-XPSUAF13AP-Harmony-XPSU-24V-ACDC-Cat-4-SIL-3-Safety-Relay-Module.jpg?v=1795574631","url":"https:\/\/szyingzhou.com\/ko\/products\/schneider-xpsuaf13ap-harmony-xpsu-safety-relay-module","provider":"YingZhou Automatization","version":"1.0","type":"link"}