{"product_id":"schneider-lr2k0307-thermal-overload-relay","title":"Schneider LR2K0307 TeSys K 1.2-1.8A Thermal Overload Relay","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Schneider Electric LR2K0307 TeSys K Thermal Overload Relay\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      1.2-1.8A | Class 10A | 1NO + 1NC | Motor Protection | TeSys K\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#3DCD58;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLR2K0307\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys K\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys LRK\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLR2K\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDifferential Thermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRelay Application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Overload Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Technology\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThermal Bimetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Protection Adjustment Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.2-1.8A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Class\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eClass 10A (IEC 60947-4-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Failure Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Unbalance Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC \/ DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLC1K \/ LC7K \/ LP1K \/ LP4K\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Arrangement\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUnder Compatible Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeparate Mounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRail or Plate with Specific Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeparate Mounting Accessory\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLA7K0064 (Sold Separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAuxiliary Contact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1NO + 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contact\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e97-98 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contact\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e95-96 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Modes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eManual \/ Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Mode Selector\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eH (Manual) \/ A (Automatic)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTest Function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRed Trip Test Button\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStop \/ Manual Reset\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBlue Pushbutton\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTrip Indication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYellow Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui), IEC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui), CSA\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage, Power Circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to 690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage, AC-15 Signalling\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage, DC-13 Signalling\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Free Air Thermal Current (Ith)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A, Signalling Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAssociated Signalling Fuse\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A gG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Dissipation per Pole\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Clamp Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Tightening Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.3 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSolid Conductor Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.5-4mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFlexible Conductor Without Ferrule\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.75-4mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFlexible Conductor With Ferrule\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.34-2.5mm², One Conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature Without Derating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature With Derating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-30°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Altitude Without Derating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Height\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e58mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Width\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Depth\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e65mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.145kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Protection Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUL \/ CSA \/ UKCA (Manufacturer Documentation)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110230437\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMade in Czech Republic (Photo Label)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LR2K0307\u003c\/strong\u003e is a \u003cstrong\u003eTeSys K \/ TeSys LRK differential thermal overload relay\u003c\/strong\u003e designed to protect industrial motors against overload conditions, phase failure and current unbalance. It features an adjustable thermal protection range of \u003cstrong\u003e1.2-1.8A\u003c\/strong\u003e and a \u003cstrong\u003eClass 10A tripping characteristic\u003c\/strong\u003e conforming to IEC 60947-4-1. The relay uses thermal bimetallic protection technology and provides \u003cstrong\u003eone normally open (1NO) and one normally closed (1NC) auxiliary contact\u003c\/strong\u003e for trip signalling and control circuits. Its front panel includes a \u003cstrong\u003emanual\/automatic reset selector\u003c\/strong\u003e, red trip test button, blue stop\/manual reset button and trip indicator. The LR2K0307 is designed for direct mounting under compatible \u003cstrong\u003eTeSys K contactors\u003c\/strong\u003e, including LC1K, LC7K, LP1K and LP4K families. Separate rail or plate mounting is possible with dedicated accessories, including the LA7K0064 terminal block, which is sold separately. The compact relay measures \u003cstrong\u003e45 x 58 x 65mm (W x H x D)\u003c\/strong\u003e and features screw-clamp terminals and IP2X protection. The supplied product and packaging photographs confirm the \u003cstrong\u003eLR2K0307\u003c\/strong\u003e model and its \u003cstrong\u003e1.2-1.8A\u003c\/strong\u003e thermal setting range. The relay must be adjusted to the applicable motor full-load current and used with appropriate upstream short-circuit protection.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTeSys K Differential Thermal Overload Relay\u003c\/strong\u003e — Schneider Electric bimetallic motor protection device for industrial control applications.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1.2-1.8A Adjustable Protection\u003c\/strong\u003e — Thermal current setting range for motors with compatible full-load current ratings.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eClass 10A Thermal Tripping\u003c\/strong\u003e — Overload protection characteristic conforming to IEC 60947-4-1.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e — Differential protection against phase loss and current unbalance conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1NO + 1NC Auxiliary Contacts\u003c\/strong\u003e — Integrated 97-98 NO and 95-96 NC contacts for motor protection signalling.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eManual and Automatic Reset\u003c\/strong\u003e — Selectable reset operation with trip test, stop\/reset control and trip indication.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTeSys K Contactor Compatibility\u003c\/strong\u003e — Direct mounting with compatible LC1K, LC7K, LP1K and LP4K contactor families.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual relay front, side and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer identification: \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Relay front model: \u003cstrong\u003eLR2K0307\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging model: \u003cstrong\u003eLR2K0307\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging thermal adjustment range: \u003cstrong\u003e1.2-1.8A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front current adjustment dial: \u003cstrong\u003e1.2A \/ 1.5A \/ 1.8A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Side marking confirms \u003cstrong\u003eClass 10A\u003c\/strong\u003e under IEC\/EN 60947-4-1\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front auxiliary contact markings: \u003cstrong\u003e97-98 NO and 95-96 NC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front controls include \u003cstrong\u003eTrip Test, Stop\/Reset and Manual\/Automatic Reset Selector\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Side label identifies \u003cstrong\u003eMade in Czech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product and packaging identification is consistent with the official LR2K0307 specifications\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm motor rated current, contactor compatibility and installation accessories before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#3DCD58;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLR2K0307\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory information. This \u003cstrong\u003eTeSys K differential thermal overload relay\u003c\/strong\u003e is available for industrial motor protection, electrical maintenance, replacement and project sourcing inquiries. The supplied actual photographs confirm the exact \u003cstrong\u003eLR2K0307\u003c\/strong\u003e model and its adjustable \u003cstrong\u003e1.2-1.8A\u003c\/strong\u003e thermal protection range. The relay is designed for use with compatible TeSys K contactors and requires appropriate upstream short-circuit protection. Please confirm the motor nameplate current, contactor compatibility, required mounting accessories, order quantity and dispatch arrangements before completing an order.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSchneider Electric LR2K0307\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 1.2-1.8A thermal setting range, Class 10A protection, 1NO+1NC auxiliary contacts and compatible motor starter configuration before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/ja\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#3DCD58;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Schneider Electric industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/ja\/collections\/schneider\" style=\"color:#3DCD58;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Schneider Electric Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LR2K0307","offer_id":58791702593839,"sku":"LR2K0307","price":27.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-LR2K0307-TeSys-K-1_2-1_8A-Thermal-Overload-Relay.jpg?v=1793947684","url":"https:\/\/szyingzhou.com\/ja\/products\/schneider-lr2k0307-thermal-overload-relay","provider":"YingZhou Automatization","version":"1.0","type":"link"}