{"title":"Industrial Auxiliary Contacts for Electrical Control Systems","description":"\n\u003cdiv style=\"width:100%;margin:0;\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"\n    background:#005EB8;\n    border-radius:12px;\n    padding:24px 28px 22px;\n    color:#FFFFFF;\n  \"\u003e\n\n    \u003cdiv style=\"\n      margin:0 0 6px;\n      font-size:10.5px;\n      line-height:1.4;\n      font-weight:700;\n      letter-spacing:1.15px;\n      text-transform:uppercase;\n      color:#FFFFFF;\n    \"\u003e\n      INDUSTRIAL AUXILIARY CONTACTS\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"\n      margin:0 0 7px;\n      color:#FFFFFF;\n      font-size:25px;\n      line-height:1.3;\n      font-weight:700;\n    \"\u003e\n      Industrial Auxiliary Contacts for Electrical Control Systems\n    \u003c\/h2\u003e\n\n    \u003cp style=\"\n      margin:0;\n      max-width:850px;\n      color:#FFFFFF;\n      font-size:14px;\n      line-height:1.6;\n    \"\u003e\n      Explore industrial auxiliary contacts designed\n      for electrical control, status indication\n      and interlocking applications. Find auxiliary\n      contact blocks, contactor auxiliary contacts,\n      circuit breaker auxiliary contacts, front-mounted\n      and side-mounted contact blocks from leading\n      manufacturers, with model identification\n      and quotation support from YINGZHOU.\n    \u003c\/p\u003e\n\n    \u003c!-- PRODUCT RANGE --\u003e\n    \u003cdiv style=\"\n      margin-top:16px;\n      padding-top:13px;\n      border-top:1px solid rgba(255,255,255,.35);\n    \"\u003e\n\n      \u003cdiv style=\"\n        margin-bottom:5px;\n        font-size:10px;\n        line-height:1.4;\n        font-weight:700;\n        letter-spacing:.9px;\n        text-transform:uppercase;\n        color:#FFFFFF;\n      \"\u003e\n        PRODUCT RANGE\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"\n        font-size:12.5px;\n        line-height:1.6;\n        font-weight:700;\n        color:#FFFFFF;\n      \"\u003e\n        Auxiliary Contact Blocks\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Contactor Auxiliary Contacts\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Circuit Breaker Auxiliary Contacts\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Front-Mounted Auxiliary Contacts\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Side-Mounted Auxiliary Contacts\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- PRODUCT FAMILIES --\u003e\n    \u003cdiv style=\"margin-top:11px;\"\u003e\n\n      \u003cdiv style=\"\n        margin-bottom:4px;\n        font-size:10px;\n        line-height:1.4;\n        font-weight:700;\n        letter-spacing:.9px;\n        text-transform:uppercase;\n        color:#FFFFFF;\n      \"\u003e\n        APPLICATIONS\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"\n        font-size:12px;\n        line-height:1.6;\n        color:#FFFFFF;\n      \"\u003e\n        Contactor Status Indication ·\n        Electrical Control Interlocking ·\n        Circuit Breaker Status Monitoring ·\n        Motor Starter Control Circuits ·\n        Industrial Control Panel Assembly\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- BUYER ASSISTANCE --\u003e\n  \u003cdiv style=\"\n    display:flex;\n    flex-wrap:wrap;\n    align-items:center;\n    justify-content:space-between;\n    gap:6px 18px;\n    margin-top:8px;\n    padding:10px 15px;\n    background:#f7f9fb;\n    border:1px solid #e8edf1;\n    border-radius:7px;\n    font-size:12.5px;\n    line-height:1.55;\n    color:#555555;\n  \"\u003e\n\n    \u003cdiv\u003e\n      \u003cstrong style=\"color:#222222;\"\u003e\n        Need a specific auxiliary contact?\n      \u003c\/strong\u003e\n      Send us the\n      \u003cstrong style=\"color:#222222;\"\u003e\n        model\/part number + quantity\n      \u003c\/strong\u003e.\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"color:#555555;white-space:nowrap;\"\u003e\n      Availability\n      \u003cspan style=\"margin:0 6px;color:#b7bec4;\"\u003e·\u003c\/span\u003e\n      Lead Time\n      \u003cspan style=\"margin:0 6px;color:#b7bec4;\"\u003e·\u003c\/span\u003e\n      Quotation\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","products":[{"product_id":"schneider-ladn22-auxiliary-contact","title":"Schneider Electric LADN22 TeSys Deca 2NO+2NC Instantaneous Auxiliary Contact Block Front Mount","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric LADN22 TeSys Deca Auxiliary Contact Block\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      2NO + 2NC | Instantaneous | Front Mounting | Screw Clamp\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FAF3;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#26853A;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FAF3;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLADN22\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys D \/ TeSys Deca\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLADN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e2NO + 2NC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Operation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eInstantaneous\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Location\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eFront\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Clamp Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V AC, 25–400 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V (IEC 60947-5-1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Thermal Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e10 A at 60°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 A at 120 V AC-15\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.04 A at 690 V AC-15\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Switching Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Switching Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e17 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMechanical Durability\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30 Million Cycles\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Product Ranges\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys D \/ Deca LC1D, CAD; TeSys F LC1F, CR1F\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-5-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LADN22\u003c\/strong\u003e is a\n      TeSys Deca instantaneous auxiliary contact block\n      designed to expand the auxiliary switching functions\n      of compatible industrial contactors and control relays.\n      It provides \u003cstrong\u003e2 normally open and 2 normally\n      closed contacts\u003c\/strong\u003e with\n      \u003cstrong\u003einstantaneous operation\u003c\/strong\u003e.\n      The module features a \u003cstrong\u003efront mounting\u003c\/strong\u003e\n      arrangement and \u003cstrong\u003escrew clamp terminals\u003c\/strong\u003e\n      for integration into compatible TeSys control systems.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FAF3;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e2NO + 2NC\u003c\/strong\u003e auxiliary contact configuration\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eInstantaneous\u003c\/strong\u003e auxiliary contact operation\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront mounting\u003c\/strong\u003e for compatible TeSys devices\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew clamp terminals\u003c\/strong\u003e for wiring connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e10A\u003c\/strong\u003e conventional thermal current at 60°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e690V\u003c\/strong\u003e rated insulation voltage under IEC 60947-5-1\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e30 million cycles\u003c\/strong\u003e mechanical durability\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#26853A;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLADN22\u003c\/strong\u003e\n        is currently in stock. This instantaneous auxiliary\n        contact block features \u003cstrong\u003e2NO + 2NC\u003c\/strong\u003e\n        contacts and front mounting for compatible TeSys\n        control equipment. Please confirm the exact model,\n        contact configuration, required quantity and\n        compatibility before ordering.\n        Contact our team for international shipping arrangements.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric LADN22\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#26853A;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#26853A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LADN22","offer_id":50328997364015,"sku":"LADN22","price":11.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-LADN22-TeSys-Deca-2NO2NC-Instantaneous-Auxiliary-Contact-Block-Front-Mount.jpg?v=1792342410"},{"product_id":"schneider-a9n26924-auxiliary-contact","title":"Schneider Electric A9N26924 Acti9 OF 1 C\/O Auxiliary Contact 240-415V AC 24-130V DC","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric A9N26924 Acti9 OF Auxiliary Contact\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      1 C\/O | 240–415V AC | 24–130V DC | 9mm Width\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FAF3;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#26853A;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Packaging Model Verified\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FAF3;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eA9N26924\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eActi9\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOC Auxiliary Contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOF\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1 C\/O (1 Changeover Contact)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e240–415V AC (Actual Packaging)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e24–130V DC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current at 240V AC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 A (AC-12)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current at 415V AC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3 A (AC-12)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current at 24V DC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 A (DC-12)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current at 48V DC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 A (DC-12)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current at 60V DC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.5 A (DC-12)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current at 130V DC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 A (DC-12)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Support\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDIN Rail\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWidth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e9 mm\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e85.3 × 9 × 73.5 mm (H × W × D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBottom Screw Clamp Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +50°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEN\/IEC 60947-5-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3606480382925\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric A9N26924\u003c\/strong\u003e is an\n      Acti9 OF auxiliary contact designed for electrical\n      status indication in compatible modular protection\n      and switching equipment. It features\n      \u003cstrong\u003e1 changeover contact (1 C\/O)\u003c\/strong\u003e\n      and supports AC\/DC signaling applications\n      within the specified electrical ratings.\n      The actual packaging identifies\n      \u003cstrong\u003e240–415V AC\u003c\/strong\u003e and\n      \u003cstrong\u003e24–130V DC\u003c\/strong\u003e.\n      Its compact \u003cstrong\u003e9mm width\u003c\/strong\u003e\n      supports integration into compatible\n      DIN rail electrical assemblies.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FAF3;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1 C\/O\u003c\/strong\u003e auxiliary changeover contact\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eOF\u003c\/strong\u003e position indication function\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e240–415V AC\u003c\/strong\u003e actual packaging voltage marking\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e24–130V DC\u003c\/strong\u003e signaling voltage range\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e6A at 240V AC\u003c\/strong\u003e under AC-12 conditions\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e9mm\u003c\/strong\u003e compact module width\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eDIN rail\u003c\/strong\u003e mounting support for compatible Acti9 assemblies\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E9DA;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Product electrical markings visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown with exact model label\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003eA9N26924\u003c\/strong\u003e\n          and electrical ratings before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#26853A;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eA9N26924\u003c\/strong\u003e\n        is currently in stock according to our inventory\n        information. This reference has been discontinued\n        by the manufacturer, but existing stock may still\n        be available for replacement requirements.\n        Actual product electrical markings and\n        Schneider packaging photos are shown.\n        Please confirm the exact model, AC\/DC ratings,\n        device compatibility and required quantity\n        before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric A9N26924\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#26853A;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#26853A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"A9N26924","offer_id":51634359370031,"sku":"A9N26924","price":11.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-A9N26924-Acti9-OF-1-CO-Auxiliary-Contact-240-415V-AC-24-130V-DC.jpg?v=1792343922"},{"product_id":"schneider-ladt0-auxiliary-contact","title":"Schneider Electric LADT0 TeSys Deca 1NO+1NC On Delay 0.3-3s Time Delay Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric LADT0 TeSys Deca Time Delay Auxiliary Contact Block\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      On Delay | 0.3–3s | 1NO + 1NC | Front Mounting\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FAF3;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#26853A;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Packaging Model Verified\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FAF3;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLADT0\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys D \/ TeSys Deca\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTime Delay Auxiliary Contact Block\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTimer Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eOn Delay\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAdjustable Time Delay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e0.3–3 Seconds\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1NO + 1NC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNC Contact Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e55–56\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNO Contact Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e67–68\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Location\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Clamp Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Thermal Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 A at ≤60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V (IEC 60947-5-1)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-5-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110385021\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LADT0\u003c\/strong\u003e is a\n      TeSys Deca time delay auxiliary contact block designed\n      for delayed auxiliary switching in compatible industrial\n      control systems. It provides an\n      \u003cstrong\u003eOn Delay\u003c\/strong\u003e function with an adjustable\n      \u003cstrong\u003e0.3–3 second\u003c\/strong\u003e time range and\n      \u003cstrong\u003e1 normally open + 1 normally closed\u003c\/strong\u003e\n      auxiliary contact configuration.\n      The unit is designed for \u003cstrong\u003efront mounting\u003c\/strong\u003e\n      and uses \u003cstrong\u003escrew clamp terminals\u003c\/strong\u003e.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FAF3;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eOn Delay\u003c\/strong\u003e auxiliary contact operation\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e0.3–3 seconds\u003c\/strong\u003e adjustable time delay\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1NO + 1NC\u003c\/strong\u003e contact configuration\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront mounting\u003c\/strong\u003e for compatible control equipment\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew clamp terminals\u003c\/strong\u003e for wiring connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e10A\u003c\/strong\u003e conventional thermal current at ≤60°C\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e690V\u003c\/strong\u003e rated insulation voltage\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E9DA;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Product electrical markings visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown with exact model label\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003eLADT0\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#26853A;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLADT0\u003c\/strong\u003e\n        is currently in stock. Actual product and packaging\n        photos are available for buyer verification.\n        Please confirm the required time delay range,\n        contact configuration and compatibility with\n        your existing control equipment before ordering.\n        Contact our team for quantity and international\n        shipping arrangements.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric LADT0\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#26853A;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#26853A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LADT0","offer_id":51919535440175,"sku":"LADT0","price":31.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-LADT0-TeSys-Deca-1NO1NC-On-Delay-0_3-3s-Time-Delay-Auxiliary-Contact-Block.jpg?v=1792344612"},{"product_id":"schneider-ladn22c-auxiliary-contact-block-tesys-d","title":"Schneider Electric LADN22C TeSys Deca 2NO+2NC Front-Mount Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric LADN22C TeSys Deca Auxiliary Contact Block\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      2NO + 2NC | 10A Ith | Front Mount | Screw Clamp Terminals\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FBF4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#278A39;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Exact Model: LADN22C\n       |  Actual Product Photos\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FBF4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLADN22C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys Deca\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLADN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Location\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eFront\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAuxiliary Contact Operation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e2 NO + 2 NC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contact Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e53–54 \/ 83–84\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contact Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e61–62 \/ 71–72\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eScrew Clamp\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Thermal Current (Ith)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e10A at ≤60°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e690V — IEC 60947-5-1\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V AC, 25–400Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Making Capacity (Irms)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e140A at ≤690V AC — IEC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePermissible Short-Time Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e100A for 1s at 60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Circuit Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10A gG Fuse — Manufacturer Specification\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMechanical Durability\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e30 Million Cycles\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Overlap Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1.5ms\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Switching Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Switching Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e17V\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInsulation Resistance\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u0026gt;10MΩ\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP2X — VDE 0106\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-5°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-60°C to +80°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Altitude\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3000m without temperature derating\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.05kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-5-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (Actual Nameplate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LADN22C\u003c\/strong\u003e\n      is a front-mounted auxiliary contact block\n      from the \u003cstrong\u003eTeSys Deca\u003c\/strong\u003e range,\n      designed to provide additional switching\n      contacts in compatible industrial control\n      and contactor systems.\n\n      The module features\n      \u003cstrong\u003e2 normally open (2NO)\u003c\/strong\u003e\n      and \u003cstrong\u003e2 normally closed (2NC)\u003c\/strong\u003e\n      auxiliary contacts with instantaneous\n      operation.\n\n      The product is rated for a\n      \u003cstrong\u003e10A conventional thermal current\n      at temperatures up to 60°C\u003c\/strong\u003e\n      and has a manufacturer-specified\n      \u003cstrong\u003e690V rated insulation voltage\u003c\/strong\u003e\n      under IEC 60947-5-1.\n\n      The LADN22C features\n      \u003cstrong\u003escrew-clamp terminals\u003c\/strong\u003e,\n      front mounting, and a documented\n      \u003cstrong\u003e1.5ms contact overlap characteristic\u003c\/strong\u003e.\n\n      Schneider Electric specifies\n      \u003cstrong\u003e30 million mechanical operating\n      cycles\u003c\/strong\u003e under the applicable\n      test conditions.\n\n      The exact model number, contact\n      configuration and electrical\n      markings are visible in the\n      actual product photographs.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FBF4;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e2NO + 2NC\u003c\/strong\u003e auxiliary contact configuration\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront mounting\u003c\/strong\u003e for compatible TeSys control devices\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e10A Ith\u003c\/strong\u003e at temperatures up to 60°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e690V Ui\u003c\/strong\u003e rated insulation voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew clamp\u003c\/strong\u003e electrical connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1.5ms\u003c\/strong\u003e documented contact overlap time\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e30 million cycles\u003c\/strong\u003e mechanical durability\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIP2X\u003c\/strong\u003e protection rating according to VDE 0106\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTeSys Deca\u003c\/strong\u003e auxiliary contact accessory\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7EBDD;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Exact model and electrical nameplate visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown with exact model label\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003eLADN22C\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#278A39;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLADN22C\u003c\/strong\u003e\n        is currently in stock according to\n        our inventory information.\n\n        Actual product, electrical nameplate\n        and packaging photographs are provided\n        for buyer verification.\n\n        Please confirm the exact model,\n        required quantity, 2NO + 2NC\n        contact arrangement, screw-clamp\n        terminal configuration and\n        host-device compatibility before ordering.\n\n        This listing is for the\n        auxiliary contact block.\n        A complete contactor is not included\n        unless separately specified.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric LADN22C\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#278A39;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#278A39;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LADN22C","offer_id":57990547964207,"sku":"LADN22C","price":5.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-LADN22C-TeSys-Deca-2NO2NC-Front-Mount-Auxiliary-Contact-Block.jpg?v=1792346888"},{"product_id":"siemens-3rh2911-1fa22-sirius-front-mount-auxiliary-contact-block","title":"Siemens 3RH2911-1FA22 SIRIUS Auxiliary Contact Block 2NO+2NC","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #009999;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#009999;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Siemens 3RH2911-1FA22 SIRIUS Auxiliary Contact Block\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      2NO + 2NC | Front-Mounted | Screw Terminals | 3RT2 \/ 3RH2\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#009999;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Photo Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH2911-1FA22\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Brand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSIRIUS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous Auxiliary Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Auxiliary Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Arrangement\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNO \/ NC \/ NC \/ NO\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Position\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSwitching Operation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntended Product Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSiemens 3RT2 Contactors \/ 3RH2 Contactor Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.057 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePackaging Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50 × 57 × 43 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePackaging Quantity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 Piece\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCzech Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Lifecycle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePM300 — Active Product\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #009999;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSiemens 3RH2911-1FA22\u003c\/strong\u003e is a\n      \u003cstrong\u003eSIRIUS front-mounted auxiliary contact block\u003c\/strong\u003e\n      designed for compatible Siemens 3RT2 contactors and\n      3RH2 contactor relays.\n      It provides a \u003cstrong\u003e2NO + 2NC auxiliary contact\n      configuration\u003c\/strong\u003e, consisting of two normally open\n      and two normally closed contacts.\n      The instantaneous auxiliary contacts can be used in\n      suitable electrical control, signaling and interlocking\n      circuits according to the connected equipment design.\n      The unit features \u003cstrong\u003escrew terminal connections\u003c\/strong\u003e\n      and a front-mounted accessory configuration.\n      Actual product and packaging photographs confirm\n      the Siemens catalog number\n      \u003cstrong\u003e3RH2911-1FA22\u003c\/strong\u003e.\n      Before ordering, verify the exact contactor model,\n      auxiliary contact configuration and installation\n      requirements.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSiemens SIRIUS Auxiliary Contact Block\u003c\/strong\u003e — Accessory for industrial control equipment.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e2NO + 2NC Configuration\u003c\/strong\u003e — Two normally open and two normally closed contacts.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFour Auxiliary Contacts\u003c\/strong\u003e — Additional switching contacts for supported control circuits.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront-Mounted Design\u003c\/strong\u003e — Front mounting on compatible Siemens devices.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eInstantaneous Switching\u003c\/strong\u003e — No intentional time-delay function.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew Terminal Connections\u003c\/strong\u003e — Electrical connections using screw terminals.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e3RT2 Series Support\u003c\/strong\u003e — Intended for compatible Siemens 3RT2 contactors.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e3RH2 Series Support\u003c\/strong\u003e — Intended for compatible Siemens 3RH2 contactor relays.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eExact Model Identification\u003c\/strong\u003e — Device and packaging marked 3RH2911-1FA22.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eActual Product Photography\u003c\/strong\u003e — Real product and packaging photographs supplied.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Siemens product and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003e3RH2911-1FA22\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical device catalog number: \u003cstrong\u003e3RH2911-1FA22\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging and device catalog numbers match\u003c\/div\u003e\n        \u003cdiv\u003e✓ Contact configuration: \u003cstrong\u003e2NO + 2NC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Four auxiliary contact positions shown on the device\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front-mounted auxiliary switch block construction\u003c\/div\u003e\n        \u003cdiv\u003e✓ Connection type: \u003cstrong\u003eScrew Terminals\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Country marking: \u003cstrong\u003eMade in Czech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging quantity: \u003cstrong\u003e1 piece\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm compatibility with the intended Siemens contactor or contactor relay before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #009999;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#009999;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Siemens \u003cstrong\u003e3RH2911-1FA22\u003c\/strong\u003e is marked\n        \u003cstrong\u003ein stock\u003c\/strong\u003e according to the supplied\n        inventory information.\n        This front-mounted SIRIUS auxiliary contact block\n        features \u003cstrong\u003e2NO + 2NC contacts\u003c\/strong\u003e,\n        instantaneous operation and screw terminal connections.\n        It is intended for compatible Siemens\n        \u003cstrong\u003e3RT2 contactors\u003c\/strong\u003e and\n        \u003cstrong\u003e3RH2 contactor relays\u003c\/strong\u003e.\n        Actual photographs support exact-model identification.\n        Contact our team for available quantities,\n        order confirmation and multi-brand industrial\n        automation sourcing.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#009999;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSiemens 3RH2911-1FA22\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model confirmation,\n        available quantities, bulk pricing and industrial\n        automation component sourcing.\n        Please confirm the 2NO + 2NC configuration,\n        mounting arrangement and compatibility with\n        your Siemens contactor before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#009999;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SIEMENS BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Siemens industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/it\/collections\/siemens\" style=\"color:#009999;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Siemens Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"SIEMENS","offers":[{"title":"3RH2911-1FA22","offer_id":58014041047343,"sku":"3RH2911-1FA22","price":16.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Siemens-3RH2911-1FA22-SIRIUS-Auxiliary-Contact-Block-2NO2NC.jpg?v=1793001501"},{"product_id":"siemens-3rh2911-1ha11-sirius-auxiliary-switch-block-1no-1nc","title":"Siemens 3RH2911-1HA11 SIRIUS 1NO+1NC Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #009999;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#009999;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Siemens 3RH2911-1HA11 SIRIUS Auxiliary Contact Block\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      1 NO + 1 NC | Front-Mounted | Screw Terminals | 3RT2 \/ 3RH2\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#009999;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSiemens AG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH2911-1HA11\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSIRIUS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH29\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Operation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Position\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront-Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront Snap-On\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 Normally Open + 1 Normally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTotal Auxiliary Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Contactor Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSelected Siemens 3RT2 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Relay Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSelected Siemens 3RH2 Contactor Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Terminal Designation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNC: .1\/.2; NO: .3\/.4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current AC-15 @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current DC-13 @ 24V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.047 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN \/ GTIN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4011209829381\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCzech Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Lifecycle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePM300 — Active Product\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #009999;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSiemens 3RH2911-1HA11\u003c\/strong\u003e is a\n      \u003cstrong\u003eSIRIUS front-mounted auxiliary contact block\u003c\/strong\u003e\n      manufactured by Siemens AG for use with selected Siemens\n      3RT2 contactors and 3RH2 contactor relays. This accessory\n      provides \u003cstrong\u003eone normally open (1 NO) and one normally\n      closed (1 NC) auxiliary contact\u003c\/strong\u003e, offering two contact\n      paths for industrial control circuit signaling, status\n      indication and interlocking functions. The contacts operate\n      instantaneously with the host switching device and use\n      \u003cstrong\u003escrew terminal connections\u003c\/strong\u003e. The block is\n      designed for \u003cstrong\u003efront snap-on mounting\u003c\/strong\u003e on\n      compatible SIRIUS switching devices. Its rated insulation\n      voltage is \u003cstrong\u003e690V AC\u003c\/strong\u003e, and the specified rated\n      operational current under \u003cstrong\u003eAC-15 at 230V is 6A\u003c\/strong\u003e.\n      The \u003cstrong\u003e3RH2911-1HA11\u003c\/strong\u003e is an auxiliary switching\n      accessory rather than a standalone power contactor.\n      The supplied actual photographs show both the physical\n      Siemens accessory and its matching packaging, with identical\n      catalog numbers and the \u003cstrong\u003e1 NO + 1 NC\u003c\/strong\u003e contact\n      configuration. The packaging label specifies\n      \u003cstrong\u003eQty: 1\u003c\/strong\u003e and identifies the\n      \u003cstrong\u003eCzech Republic\u003c\/strong\u003e as the country of manufacture.\n      Please verify your host contactor model, mounting requirements\n      and auxiliary contact arrangement before ordering.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSiemens SIRIUS Auxiliary Contact Block\u003c\/strong\u003e — Front-mounted industrial switching accessory for compatible Siemens 3RT2 contactors and 3RH2 contactor relays.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1NO + 1NC Configuration\u003c\/strong\u003e — One normally open and one normally closed auxiliary contact.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTwo Auxiliary Contact Paths\u003c\/strong\u003e — Supports control circuit signaling, feedback and interlocking functions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront Snap-On Mounting\u003c\/strong\u003e — Designed for front attachment to supported Siemens switching devices.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew Terminal Connections\u003c\/strong\u003e — Conventional terminal wiring for industrial control applications.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e6A AC-15 at 230V\u003c\/strong\u003e — Manufacturer-specified auxiliary contact operational current.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eActual Product Photography\u003c\/strong\u003e — The Siemens accessory and matching packaging are shown for exact-model verification.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Siemens product and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003e3RH2911-1HA11\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical device catalog number: \u003cstrong\u003e3RH2911-1HA11\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Contact configuration: \u003cstrong\u003e1 NO + 1 NC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front-mounted auxiliary contact block design\u003c\/div\u003e\n        \u003cdiv\u003e✓ Screw terminal connection configuration\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rated insulation voltage marking: \u003cstrong\u003e690V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rated AC-15 current at 230V: \u003cstrong\u003e6A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging EAN: \u003cstrong\u003e4011209829381\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging quantity: \u003cstrong\u003e1 piece\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Country of manufacture: \u003cstrong\u003eCzech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical product and packaging model numbers match\u003c\/div\u003e\n        \u003cdiv\u003e✓ Verify exact host contactor compatibility before purchasing\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #009999;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#009999;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Siemens \u003cstrong\u003e3RH2911-1HA11\u003c\/strong\u003e is marked\n        \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory\n        information. This SIRIUS auxiliary contact block features\n        \u003cstrong\u003eone normally open and one normally closed contact\u003c\/strong\u003e,\n        front-mounted installation and screw terminal connections\n        for selected Siemens 3RT2 contactors and 3RH2 contactor\n        relays. Actual product and packaging photographs are\n        available for exact-model identification. The photographed\n        packaging is marked \u003cstrong\u003eQty: 1\u003c\/strong\u003e. Please confirm\n        your host switching device and the required 1NO+1NC\n        contact arrangement before completing an order.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#009999;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSiemens 3RH2911-1HA11\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, individual unit\n        orders, bulk quantities and Siemens SIRIUS accessory\n        sourcing. Please confirm the 1NO+1NC configuration and\n        your compatible 3RT2 or 3RH2 device before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#009999;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SIEMENS BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Siemens industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/it\/collections\/siemens\" style=\"color:#009999;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Siemens Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"SIEMENS","offers":[{"title":"3RH2911-1HA11","offer_id":58065382375727,"sku":"3RH2911-1HA11","price":10.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Siemens-3RH2911-1HA11-SIRIUS-1NO1NC-Auxiliary-Contact-Block.jpg?v=1793001579"},{"product_id":"siemens-3rh2911-1ha22-sirius-auxiliary-switch-block-2no-2nc","title":"Siemens 3RH2911-1HA22 SIRIUS 2NO+2NC Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #009999;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#009999;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Siemens 3RH2911-1HA22 SIRIUS Auxiliary Contact Block\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      2 NO + 2 NC | Front-Mounted | Screw Terminals | 3RT2 \/ 3RH2\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#009999;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSiemens AG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH2911-1HA22\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSIRIUS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH29\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Operation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Position\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront-Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront Snap-On\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 Normally Open + 2 Normally Closed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTotal Auxiliary Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Contactor Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSelected Siemens 3RT2 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Relay Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSelected Siemens 3RH2 Contactor Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Terminal Designation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNC: .1\/.2; NO: .3\/.4\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current AC-15 @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current DC-13 @ 24V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN \/ GTIN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4011209829312\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCzech Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Lifecycle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePM300 — Active Product\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #009999;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSiemens 3RH2911-1HA22\u003c\/strong\u003e is a \u003cstrong\u003eSIRIUS front-mounted auxiliary contact block\u003c\/strong\u003e manufactured by Siemens AG for use with selected Siemens 3RT2 contactors and 3RH2 contactor relays. This accessory provides \u003cstrong\u003etwo normally open (2 NO) and two normally closed (2 NC) auxiliary contacts\u003c\/strong\u003e, offering four contact paths for industrial switching, signaling and interlocking control circuits. The auxiliary contacts operate instantaneously with the host switching device and use \u003cstrong\u003escrew terminal connections\u003c\/strong\u003e. The block is designed for \u003cstrong\u003efront snap-on mounting\u003c\/strong\u003e to compatible SIRIUS contactors or contactor relays. Its specified rated insulation voltage is \u003cstrong\u003e690V AC\u003c\/strong\u003e, and the rated operational current under \u003cstrong\u003eAC-15 at 230V is 6A\u003c\/strong\u003e. The \u003cstrong\u003e3RH2911-1HA22\u003c\/strong\u003e is an auxiliary switching accessory rather than a standalone power contactor. The supplied actual photographs show both the physical Siemens accessory and the corresponding packaging, with matching catalog numbers and the \u003cstrong\u003e2 NO + 2 NC\u003c\/strong\u003e configuration. The packaging label specifies \u003cstrong\u003eQty: 1\u003c\/strong\u003e and identifies \u003cstrong\u003eCzech Republic\u003c\/strong\u003e as the country of manufacture. Please verify your host contactor model, mounting requirements and contact arrangement before ordering.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSiemens SIRIUS Auxiliary Contact Block\u003c\/strong\u003e — Front-mounted industrial switching accessory for compatible Siemens 3RT2 contactors and 3RH2 contactor relays.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e2NO + 2NC Configuration\u003c\/strong\u003e — Two normally open and two normally closed auxiliary contacts.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFour Auxiliary Contact Paths\u003c\/strong\u003e — Suitable for control circuit signaling and interlocking functions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront Snap-On Mounting\u003c\/strong\u003e — Designed for front installation on supported Siemens switching devices.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew Terminal Connections\u003c\/strong\u003e — Conventional wiring connection for industrial control panels.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e6A AC-15 at 230V\u003c\/strong\u003e — Manufacturer-specified auxiliary contact operational current.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eActual Product Photography\u003c\/strong\u003e — The Siemens accessory and matching original packaging are shown for model verification.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Siemens product and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003e3RH2911-1HA22\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical device catalog number: \u003cstrong\u003e3RH2911-1HA22\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Contact configuration: \u003cstrong\u003e2 NO + 2 NC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front-mounted auxiliary contact block design\u003c\/div\u003e\n        \u003cdiv\u003e✓ Screw terminal connection configuration\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rated insulation voltage marking: \u003cstrong\u003e690V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rated AC-15 current at 230V: \u003cstrong\u003e6A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging EAN: \u003cstrong\u003e4011209829312\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging quantity: \u003cstrong\u003e1 piece\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Country of manufacture: \u003cstrong\u003eCzech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical product and packaging model numbers match\u003c\/div\u003e\n        \u003cdiv\u003e✓ Verify exact host contactor compatibility before purchasing\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #009999;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#009999;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Siemens \u003cstrong\u003e3RH2911-1HA22\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory information. This SIRIUS auxiliary contact block features \u003cstrong\u003etwo normally open and two normally closed contacts\u003c\/strong\u003e, front-mounted installation and screw terminal connections for selected Siemens 3RT2 contactors and 3RH2 contactor relays. Actual photographs of the physical item and Siemens packaging are available for exact-model identification. The photographed package is marked \u003cstrong\u003eQty: 1\u003c\/strong\u003e. Please confirm the exact contactor or relay model and required contact configuration before completing an order.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#009999;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSiemens 3RH2911-1HA22\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, individual unit orders, bulk quantities and Siemens SIRIUS accessory sourcing. Please confirm the 2NO+2NC configuration and your compatible 3RT2 or 3RH2 device before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#009999;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SIEMENS BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Siemens industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/it\/collections\/siemens\" style=\"color:#009999;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Siemens Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"SIEMENS","offers":[{"title":"3RH2911-1HA22","offer_id":58065387094319,"sku":"3RH2911-1HA22","price":14.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Siemens-3RH2911-1HA22-SIRIUS-2NO2NC-Auxiliary-Contact-Block.jpg?v=1793001586"},{"product_id":"siemens-3rh1921-1ca01-sirius-auxiliary-switch-block-1nc","title":"Siemens 3RH1921-1CA01 SIRIUS 1NC Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #009999;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#009999;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Siemens 3RH1921-1CA01 SIRIUS Auxiliary Contact Block\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      1 NC | Front-Mounted | Screw Terminals | Siemens 3RT1\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#009999;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSiemens AG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH1921-1CA01\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSIRIUS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH19\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Position\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront-Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSnap-On Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 Normally Closed (1 NC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Contactor Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSelected Siemens 3RT1 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current AC-15 @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current DC-13 @ 24V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e38mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e51mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.5–2.5mm², Solid or Stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e18g\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN \/ GTIN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4011209281639\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCzech Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Lifecycle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePM300 — Active Product\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #009999;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSiemens 3RH1921-1CA01\u003c\/strong\u003e is a \u003cstrong\u003eSIRIUS front-mounted auxiliary contact block\u003c\/strong\u003e designed for use with selected Siemens 3RT1 contactors. The accessory provides \u003cstrong\u003eone normally closed (1 NC) auxiliary contact\u003c\/strong\u003e for industrial control and signaling circuits. It features \u003cstrong\u003efront snap-on mounting\u003c\/strong\u003e and \u003cstrong\u003escrew terminal connections\u003c\/strong\u003e for installation on supported contactor assemblies. The manufacturer specifies a \u003cstrong\u003e690V AC rated insulation voltage\u003c\/strong\u003e, a rated operational current of \u003cstrong\u003e6A at 230V AC-15\u003c\/strong\u003e, and a rated operational current of \u003cstrong\u003e6A at 24V DC-13\u003c\/strong\u003e. Its compact dimensions are \u003cstrong\u003e38mm high, 10mm wide and 51mm deep\u003c\/strong\u003e, with an operating ambient temperature range from \u003cstrong\u003e-25°C to +60°C\u003c\/strong\u003e. This auxiliary contact block is intended for control circuit switching and is not a standalone power contactor. The supplied actual product photographs show the accessory and Siemens packaging, both identifying \u003cstrong\u003e3RH1921-1CA01\u003c\/strong\u003e. The packaging specifies the \u003cstrong\u003e1 NC\u003c\/strong\u003e configuration, a \u003cstrong\u003e10-piece box quantity\u003c\/strong\u003e, and \u003cstrong\u003eCzech Republic\u003c\/strong\u003e as the manufacturing origin. Before ordering, please confirm your exact contactor model and required normally closed contact arrangement.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSiemens SIRIUS Auxiliary Contact Block\u003c\/strong\u003e — Front-mounted industrial switching accessory for compatible Siemens 3RT1 contactors.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1 Normally Closed Contact\u003c\/strong\u003e — Provides one NC auxiliary contact for control and signaling circuits.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront Snap-On Mounting\u003c\/strong\u003e — Designed for attachment to supported Siemens contactors.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew Terminal Connection\u003c\/strong\u003e — Supports standard industrial wiring methods.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e6A AC-15 at 230V\u003c\/strong\u003e — Manufacturer-specified operational switching current.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e — Dimensions of 38 × 10 × 51mm.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eActual Product Photography\u003c\/strong\u003e — The accessory and original packaging are shown with matching exact-model markings.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Siemens accessory and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003e3RH1921-1CA01\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical device catalog number: \u003cstrong\u003e3RH1921-1CA01\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Contact arrangement: \u003cstrong\u003e1 Normally Closed (1 NC)\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front-mounted auxiliary contact block design\u003c\/div\u003e\n        \u003cdiv\u003e✓ Screw terminal connection configuration\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rated insulation voltage marking: \u003cstrong\u003e690V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ AC-15 operational current @ 230V: \u003cstrong\u003e6A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ EAN barcode: \u003cstrong\u003e4011209281639\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Original packaging marked \u003cstrong\u003eQty: 10\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Country of origin: \u003cstrong\u003eCzech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging and physical product model numbers match\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm host contactor compatibility and required purchasing quantity before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #009999;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#009999;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Siemens \u003cstrong\u003e3RH1921-1CA01\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on supplied inventory information. This front-mounted SIRIUS auxiliary contact block provides \u003cstrong\u003eone normally closed contact\u003c\/strong\u003e for compatible Siemens 3RT1 contactor systems. Actual photographs of the physical product and Siemens packaging are available for exact-model identification. The photographed packaging is marked \u003cstrong\u003eQty: 10\u003c\/strong\u003e. Please confirm whether your order requires individual pieces or a complete box, and verify the exact contactor model before purchasing.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#009999;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSiemens 3RH1921-1CA01\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model confirmation, individual piece orders, bulk quantities and Siemens SIRIUS accessory sourcing. Please verify the 1 NC configuration, compatible 3RT1 contactor and required order quantity before purchasing.\n      \u003c\/p\u003e\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#009999;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SIEMENS BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Siemens industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/it\/collections\/siemens\" style=\"color:#009999;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Siemens Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"SIEMENS","offers":[{"title":"3RH1921-1CA01","offer_id":58065392828719,"sku":"3RH1921-1CA01","price":5.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Siemens-3RH1921-1CA01-SIRIUS-1NC-Auxiliary-Contact-Block.jpg?v=1793001594"},{"product_id":"siemens-3rh1921-1ca10-sirius-auxiliary-switch-block-1no","title":"Siemens 3RH1921-1CA10 SIRIUS 1NO Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #009999;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#009999;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Siemens 3RH1921-1CA10 SIRIUS Auxiliary Contact Block\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      1 NO | Front-Mounted | Screw Terminals | For Siemens 3RT1\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#009999;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSiemens AG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH1921-1CA10\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSIRIUS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RH19\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Position\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront-Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSnap-On\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 Normally Open (1 NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Contactor Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSelected Siemens 3RT1 Contactors\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-12 Operational Current @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-15 Operational Current @ 24V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-15 Operational Current @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-15 Operational Current @ 400V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-13 Operational Current @ 24V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Protection Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMechanical Service Life\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10,000,000 Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eElectrical Endurance AC-15 @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e200,000 Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e19g\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePackaging Box Quantity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 Pieces (Actual Packaging)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCzech Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN \/ GTIN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4011209281332\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #009999;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSiemens 3RH1921-1CA10\u003c\/strong\u003e is a \u003cstrong\u003eSIRIUS front-mounted auxiliary contact block\u003c\/strong\u003e designed for use with selected Siemens 3RT1 contactors. This one-pole accessory provides \u003cstrong\u003eone normally open (1 NO) auxiliary contact\u003c\/strong\u003e for control and signaling circuits. Its front snap-on mounting design allows installation on compatible contactor assemblies, while \u003cstrong\u003escrew terminals\u003c\/strong\u003e provide electrical connections for industrial control wiring. The manufacturer specifies a rated operational current of \u003cstrong\u003e6A at 230V AC-15\u003c\/strong\u003e and \u003cstrong\u003e3A at 400V AC-15\u003c\/strong\u003e, together with an insulation voltage rating of \u003cstrong\u003e690V AC\u003c\/strong\u003e and a rated impulse withstand voltage of \u003cstrong\u003e6kV\u003c\/strong\u003e. The front protection rating is \u003cstrong\u003eIP20\u003c\/strong\u003e, with an operating temperature range of \u003cstrong\u003e-25°C to +60°C\u003c\/strong\u003e. The Siemens 3RH1921-1CA10 is intended as an auxiliary switching accessory and must not be used as a main power contactor. The supplied actual product photographs show the Siemens accessory, including its exact catalog number and electrical rating label. The original Siemens packaging also identifies the model \u003cstrong\u003e3RH1921-1CA10\u003c\/strong\u003e, the \u003cstrong\u003e1 NO\u003c\/strong\u003e contact arrangement, and a packaging quantity of \u003cstrong\u003e10 pieces\u003c\/strong\u003e. The device and packaging are marked \u003cstrong\u003eMade in Czech Republic\u003c\/strong\u003e. Before ordering, please confirm your exact contactor model and the required auxiliary contact configuration.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSiemens SIRIUS Auxiliary Contact Block\u003c\/strong\u003e — Industrial control accessory for compatible Siemens 3RT1 contactors.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1 Normally Open Contact\u003c\/strong\u003e — Adds one auxiliary NO switching contact to a supported contactor assembly.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront Snap-On Mounting\u003c\/strong\u003e — Designed for mounting directly onto compatible contactors.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew Terminal Design\u003c\/strong\u003e — Supports conventional industrial control wiring.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e6A AC-15 at 230V\u003c\/strong\u003e — Manufacturer-specified auxiliary circuit operational current.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIP20 Front Protection\u003c\/strong\u003e — Front protection rating for the specified accessory design.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eActual Product Photography\u003c\/strong\u003e — Real photographs of the Siemens accessory and its packaging support exact-model identification.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Siemens accessory and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003e3RH1921-1CA10\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical device model marking: \u003cstrong\u003e3RH1921-1CA10\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Contact arrangement: \u003cstrong\u003e1 Normally Open (1 NO)\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front-mounted auxiliary contact block design\u003c\/div\u003e\n        \u003cdiv\u003e✓ Screw terminal connection configuration\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical label identifies \u003cstrong\u003e690V AC insulation rating\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ AC-15 operational current at 230V: \u003cstrong\u003e6A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging EAN: \u003cstrong\u003e4011209281332\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Original packaging marked \u003cstrong\u003eQty: 10\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging and physical device origin: \u003cstrong\u003eCzech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Exact packaging and device catalog numbers match\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm required order quantity and specific contactor compatibility before shipment\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #009999;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#009999;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Siemens \u003cstrong\u003e3RH1921-1CA10\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory information. This SIRIUS auxiliary contact block is offered for industrial maintenance, electrical control panel procurement and replacement accessory requirements. The device provides \u003cstrong\u003eone normally open auxiliary contact\u003c\/strong\u003e and is designed for front mounting on compatible Siemens 3RT1 contactors. Actual photographs of the physical product and original packaging are available for model identification. The photographed packaging is labeled as a \u003cstrong\u003e10-piece box\u003c\/strong\u003e; please confirm whether your order requires individual pieces or the complete box. Verify the exact host contactor, contact arrangement, auxiliary circuit ratings and final dispatch quantity before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#009999;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSiemens 3RH1921-1CA10\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, individual pieces, complete box quantities and Siemens SIRIUS accessory sourcing. Please confirm the 1 NO configuration and compatibility with your specific 3RT1 contactor before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#009999;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SIEMENS BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Siemens industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/it\/collections\/siemens\" style=\"color:#009999;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Siemens Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"SIEMENS","offers":[{"title":"3RH1921-1CA10","offer_id":58065491853615,"sku":"3RH1921-1CA10","price":5.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Siemens-3RH1921-1CA10-SIRIUS-1NO-Auxiliary-Contact-Block.jpg?v=1793001600"},{"product_id":"abb-cal18x-11-auxiliary-contact-block","title":"ABB CAL18X-11 1SFN019820R1011 AX95-AX205 1NO+1NC Side-Mounted Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#fff;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      ABB CAL18X-11 1NO+1NC Side-Mounted Auxiliary Contact Block\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#fff;\"\u003e\n      1SFN019820R1011 | 1NO+1NC | AX95–AX205 | AC-15 3A at 400V\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF2F2;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#FF0000;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#FFF2F2;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eCAL18X-11\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOrder Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SFN019820R1011\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAX Contactor Accessories\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eSide-Mounted\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1NO + 1NC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Poles\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSuitable Contactors\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eABB AX95–AX205\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUtilization Category\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC-15\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperational Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3 A at 400 V AC (AC-15)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Origin\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB CAL18X-11\u003c\/strong\u003e is a side-mounted\n      auxiliary contact block designed for ABB AX series contactors.\n      It provides \u003cstrong\u003e1 normally open (1NO) and\n      1 normally closed (1NC) contact\u003c\/strong\u003e for auxiliary\n      control and signalling circuits.\n      The module is suitable for\n      \u003cstrong\u003eABB AX95–AX205 contactors\u003c\/strong\u003e and features\n      screw terminal connections.\n      Its original packaging identifies an\n      \u003cstrong\u003eAC-15 operational rating of 3 A at 400 V AC\u003c\/strong\u003e.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF2F2;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#FF0000;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1NO + 1NC\u003c\/strong\u003e auxiliary contact configuration\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSide-mounted\u003c\/strong\u003e instantaneous auxiliary contact block\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eAX95–AX205\u003c\/strong\u003e contactor compatibility\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eAC-15\u003c\/strong\u003e utilization category\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e3 A at 400 V AC\u003c\/strong\u003e operational rating\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew terminal\u003c\/strong\u003e connection\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eABB order code 1SFN019820R1011\u003c\/strong\u003e for exact-model identification\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#FF0000;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          Actual product packaging photo\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          Exact model \u003cstrong\u003eCAL18X-11\u003c\/strong\u003e visible on packaging\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          ABB order code \u003cstrong\u003e1SFN019820R1011\u003c\/strong\u003e visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown with contact rating and compatibility information\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003eCAL18X-11\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#FF0000;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003eCAL18X-11\u003c\/strong\u003e is currently in stock.\n        Order online or contact YINGZHOU for quantity-based quotations\n        and industrial procurement support.\n        Please confirm the required quantity, sales unit,\n        and exact model before purchasing.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#fff;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#fff;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003e\n        ABB CAL18X-11\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#FF0000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other ABB industrial automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/collections\/abb\" style=\"color:#FF0000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore ABB Industrial Automation Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"CAL18X-11","offer_id":58095780823343,"sku":"CAL18X-11","price":5.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-CAL18X-11-1SFN019820R1011-AX95-AX205-1NO1NC-Side-Mounted-Auxiliary-Contact-Block.jpg?v=1792347294"},{"product_id":"abb-1sda104825r1-aux-sc-s33-signal-contact","title":"ABB 1SDA104825R1 AUX-SC S33 M\/2 250V AC\/DC XT7M Spring-Charged Indication Auxiliary Contact","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#fff;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      ABB 1SDA104825R1 AUX-SC S33 Spring-Charged Indication Contact\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#fff;\"\u003e\n      AUX-SC S33 M\/2 | 250V AC\/DC Class | 1 Changeover Contact | XT7M\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF2F2;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#FF0000;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#FFF2F2;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SDA104825R1\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Designation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAUX-SC S33 M\/2 250V AC\/DC XT7M\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpring-Charged Indication Auxiliary Contact\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Category\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCircuit Breaker Accessory\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSignal Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eS33\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eSpring-Charged Electrical Indication\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1 Changeover Contact (SPDT)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Voltage Specification\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eV \u0026lt; 250V AC\/DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Breaker\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eABB XT7M\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSACE Tmax XT\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standards\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC 60947-2 \/ UL 489\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.048 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e8015644069179\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB 1SDA104825R1\u003c\/strong\u003e is an\n      \u003cstrong\u003eAUX-SC S33 spring-charged indication auxiliary contact\u003c\/strong\u003e\n      designed for compatible ABB Tmax XT circuit breakers.\n      Identified as \u003cstrong\u003eAUX-SC S33 M\/2 250V AC\/DC XT7M\u003c\/strong\u003e,\n      this accessory provides an electrical indication of the\n      breaker mechanism's stored-energy spring status.\n      It incorporates \u003cstrong\u003eone changeover contact (SPDT)\u003c\/strong\u003e\n      for auxiliary signalling and is specified for\n      \u003cstrong\u003eABB XT7M\u003c\/strong\u003e applications.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF2F2;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#FF0000;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eAUX-SC S33\u003c\/strong\u003e spring-charged indication accessory\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eStored-energy spring status\u003c\/strong\u003e electrical signalling\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e250V AC\/DC class\u003c\/strong\u003e contact specification\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1 changeover contact (SPDT)\u003c\/strong\u003e configuration\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eABB XT7M\u003c\/strong\u003e circuit breaker compatibility\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSACE Tmax XT\u003c\/strong\u003e accessory family\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExact ABB order code 1SDA104825R1\u003c\/strong\u003e for procurement verification\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#FF0000;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          Actual product packaging photo\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          Exact ABB order code \u003cstrong\u003e1SDA104825R1\u003c\/strong\u003e visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          AUX-SC S33 M\/2 250V AC\/DC XT7M description shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown for pre-purchase verification\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#FF0000;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003e1SDA104825R1\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#FF0000;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003e1SDA104825R1\u003c\/strong\u003e is currently in stock.\n        Order online or contact YINGZHOU for quantity-based quotations\n        and industrial procurement support.\n        Please confirm the exact breaker configuration and\n        \u003cstrong\u003eS33 spring-charged indication\u003c\/strong\u003e function before purchasing.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#fff;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#fff;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003e\n        ABB 1SDA104825R1\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#FF0000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other ABB industrial automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/collections\/abb\" style=\"color:#FF0000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore ABB Industrial Automation Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"1SDA104825R1","offer_id":58096015769903,"sku":"1SDA104825R1","price":27.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-1SDA104825R1-AUX-SC-S33-M2-250V-ACDC-XT7M-Spring-Charged-Indication-Auxiliary-Contact.jpg?v=1792347314"},{"product_id":"abb-cal18-11-auxiliary-contact-1sfn010720r1011","title":"ABB CAL18-11 1SFN010720R1011 2-Pole 1NO+1NC Side-Mounted Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\u003c!-- HERO --\u003e\n\u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n\u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003eYingZhou Industrial Automation | Product Information\u003c\/div\u003e\n\u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003eABB CAL18-11 Auxiliary Contact Block\u003c\/h2\u003e\n\u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e1SFN010720R1011 | 2-Pole | 1NO + 1NC | Side-Mounted\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- STOCK STATUS --\u003e\n\u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓ IN STOCK \u0026amp; READY TO ORDER\u003c\/strong\u003e\n\u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Packaging Label Verified\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctr style=\"background:#FFF4F4;\"\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eCAL18-11\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOrder Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SFN010720R1011\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSide-Mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1 NO + 1 NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Operation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e24–690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Thermal Current (Ith)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current AC-15\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 A at 24–127 V AC\u003cbr\u003e4 A at 220–240 V AC\u003cbr\u003e3 A at 380–440 V AC\u003cbr\u003e2 A at 500–690 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"padding:30px;\"\u003e\n\u003c!-- PRODUCT OVERVIEW --\u003e\n\u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003eThe \u003cstrong\u003eABB CAL18-11\u003c\/strong\u003e, ordering code \u003cstrong\u003e1SFN010720R1011\u003c\/strong\u003e, is a side-mounted auxiliary contact block designed to provide additional switching contacts for compatible ABB contactors. Featuring \u003cstrong\u003eone normally open (1NO) and one normally closed (1NC) instantaneous contact\u003c\/strong\u003e, this two-pole accessory supports auxiliary control and signaling functions in industrial electrical systems. The module features screw terminals and is rated according to IEC\/EN 60947-5-1. Verify the host contactor model and applicable electrical ratings before installation.\u003c\/p\u003e\n\u003c!-- KEY PRODUCT FEATURES --\u003e\n\u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n\u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e2-Pole Auxiliary Contact Block\u003c\/strong\u003e — 1NO + 1NC contact arrangement.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eInstantaneous Operation\u003c\/strong\u003e — For auxiliary signaling and control circuits.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSide-Mounted Design\u003c\/strong\u003e — For selected compatible ABB contactors.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew Terminal Connection\u003c\/strong\u003e — For auxiliary control wiring.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e690V Rated Insulation Voltage\u003c\/strong\u003e — According to IEC\/EN 60947-5-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16A Conventional Thermal Current\u003c\/strong\u003e — With duty-specific AC-15 operating current ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n\u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n\u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n\u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Actual inventory packaging photo provided\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e ABB CAL18-11 model visible on the packaging label\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e ABB order code 1SFN010720R1011 matches the manufacturer product listing\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Confirm host contactor compatibility and ordering quantity before purchase\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- AVAILABILITY --\u003e\n\u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003eIn Stock \u0026amp; Ready to Order\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003eABB \u003cstrong\u003eCAL18-11\u003c\/strong\u003e auxiliary contact block, ordering code \u003cstrong\u003e1SFN010720R1011\u003c\/strong\u003e, is currently in stock according to our inventory information. Actual packaging photography is available for product identification. Please confirm your required quantity and compatible ABB contactor model before ordering.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- CTA --\u003e\n\u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003eIN STOCK\u003c\/div\u003e\n\u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003eABB CAL18-11 | 1SFN010720R1011\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003eOrder online or contact us for project and quantity pricing.\u003c\/p\u003e\n\u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Project Pricing\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c!-- ABB BRAND COLLECTION INTERNAL LINK --\u003e\n\u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other ABB industrial automation products?\u003c\/p\u003e\n\u003ca href=\"\/it\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore ABB Industrial Automation Products\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"CAL18-11","offer_id":58338931212591,"sku":"CAL18-11","price":9.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-CAL18-11-1SFN010720R1011-2-Pole-1NO1NC-Side-Mounted-Auxiliary-Contact-Block.jpg?v=1792348317"},{"product_id":"schneider-ladn40-4no-auxiliary-contact-block","title":"Schneider LADN40 TeSys Deca 4NO 10A 690V Front-Mount Auxiliary Contact Block","description":"\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#ffffff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#ffffff;line-height:1.3;\"\u003e\n      Schneider LADN40 TeSys Deca Auxiliary Contact Block\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      4NO | 10A Ith | 690V Ui | Front Mount\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F3FBF5;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#16852A;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Brand New Original\n       |  1-Year Seller Warranty\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F3FBF5;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003e\n        Specification\n      \u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003e\n        Product Data\n      \u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLADN40\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys Deca \/ TeSys D\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Composition\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e4 NO + 0 NC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Operation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Location\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Clamp Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Current [Ith]\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e10 A at ≤60°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage [Ui]\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e690 V\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage [Ue]\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V AC, 25–400 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMechanical Durability\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30 Million Cycles\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LADN40\u003c\/strong\u003e is a\n      \u003cstrong\u003eTeSys Deca front-mounted auxiliary contact block\u003c\/strong\u003e\n      featuring \u003cstrong\u003e4 normally open instantaneous contacts\u003c\/strong\u003e.\n      It uses screw clamp terminals and is designed for industrial\n      control and signalling circuits.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F3FBF5;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#16852A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e4 NO + 0 NC\u003c\/strong\u003e instantaneous auxiliary contacts\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront-mount\u003c\/strong\u003e auxiliary contact block\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e10 A Ith\u003c\/strong\u003e at temperatures up to 60°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e690 V Ui\u003c\/strong\u003e according to IEC 60947-5-1\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\u003cstrong\u003eScrew clamp terminals\u003c\/strong\u003e\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e30 million cycles\u003c\/strong\u003e mechanical durability\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D6EEDB;border-radius:8px;background:#FAFDFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#16852A;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#16852A;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#16852A;\"\u003e✓\u003c\/strong\u003e\n          Product appearance shown for buyer verification\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#16852A;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown where available\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#16852A;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003eLADN40\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#16852A;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLADN40\u003c\/strong\u003e is currently in stock.\n        Brand new original unit with a \u003cstrong\u003e1-year seller warranty\u003c\/strong\u003e.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#111;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#111;font-size:20px;\"\u003e\n        Schneider Electric LADN40\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#111;\"\u003e\n        Order online or contact us for quantity and project pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#111;color:#fff;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Bulk Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- MANDATORY SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#16852A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"LADN40","offer_id":58554630013231,"sku":"LADN40","price":12.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-LADN40-TeSys-Deca-4NO-10A-690V-Front-Mount-Auxiliary-Contact-Block.jpg?v=1790610215"},{"product_id":"schneider-ladn31-auxiliary-contact-block","title":"Schneider LADN31 TeSys Deca 3NO+1NC Instantaneous Auxiliary Contact Block Front Mounting","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider LADN31 TeSys Deca Auxiliary Contact Block\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      3NO + 1NC | Instantaneous | Front Mounting | Screw Terminals\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FBF4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#258A3C;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Model \u0026amp; Packaging Verified\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FBF4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLADN31\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys Deca \/ TeSys D\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous Auxiliary Contact Block\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLADN\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3 NO + 1 NC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Contacts\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 Auxiliary Contacts\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Operation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Location\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eFront Mounting\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConnection Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Clamp Terminals\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contacts\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e53–54 \/ 73–74 \/ 83–84\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contact\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e61–62\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Thermal Current (Ith)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e10 A at 60°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V AC, 25–400 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL \/ CSA Insulation Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e600 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-15 Operational Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 A at 120 V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-15 Operational Current at 690 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.04 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-13 Operational Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.55 A at 125 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMechanical Durability\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e30 Million Cycles\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Switching Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Switching Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e17 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP2X\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-5°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Compatibility\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCompatible TeSys LC1D \/ LC1F \/ CAD \/ CR1F Devices\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e48 × 44 × 42 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-5-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCzech Republic (Photo Verified)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LADN31\u003c\/strong\u003e\n      is an \u003cstrong\u003einstantaneous auxiliary contact block\u003c\/strong\u003e\n      from the \u003cstrong\u003eTeSys Deca Series\u003c\/strong\u003e.\n      It features a \u003cstrong\u003e3 normally open (3NO)\n      and 1 normally closed (1NC)\u003c\/strong\u003e contact configuration,\n      designed for front mounting on compatible TeSys\n      contactors and control relays.\n      The module provides a\n      \u003cstrong\u003e10 A conventional thermal current rating\n      at 60°C\u003c\/strong\u003e and supports a\n      \u003cstrong\u003e690 V AC operational voltage rating\u003c\/strong\u003e,\n      subject to the applicable switching load category.\n      It uses screw clamp terminals for industrial\n      control circuit connections.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FBF4;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#258A3C;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e3NO + 1NC\u003c\/strong\u003e instantaneous auxiliary contact configuration\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront mounting\u003c\/strong\u003e for compatible TeSys contactors and control relays\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e10 A Ith\u003c\/strong\u003e conventional thermal current at 60°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e690 V AC\u003c\/strong\u003e rated operational voltage under specified conditions\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew clamp terminals\u003c\/strong\u003e for control circuit wiring\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e30 million mechanical cycles\u003c\/strong\u003e manufacturer-specified durability\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eIEC\/EN 60947-5-1\u003c\/strong\u003e industrial control device standard\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #CFEBD5;border-radius:8px;background:#FAFEFB;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#258A3C;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#258A3C;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#258A3C;\"\u003e✓\u003c\/strong\u003e\n          Model\/nameplate visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#258A3C;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#258A3C;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003eLADN31\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#258A3C;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLADN31\u003c\/strong\u003e\n        is currently in stock.\n        Actual product photos, terminal markings and\n        packaging label are available for exact-model verification.\n        Please confirm the \u003cstrong\u003e3NO + 1NC contact arrangement\u003c\/strong\u003e,\n        front-mounting compatibility, terminal type\n        and required switching load ratings before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider LADN31\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#258A3C;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#258A3C;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LADN31","offer_id":58658521940271,"sku":"LADN31","price":11.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-LADN31-TeSys-Deca-3NO1NC-Instantaneous-Auxiliary-Contact-Block-Front-Mounting.jpg?v=1792055805"},{"product_id":"abb-s2c-h6r","title":"ABB S2C-H6R 2CDS200912R0001 1CO SPDT Right-Side Auxiliary Contact for S200 MCB","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      ABB S2C-H6R 1CO Auxiliary Contact\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      1CO \/ SPDT | Right-Side Mounting | AC-14 | S200 Compatible\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#FF0000;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Packaging Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eS2C-H6R\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Order Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2CDS200912R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSystem pro M compact Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1 CO \/ SPDT Changeover\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Changeover Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFunction\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eContact Position Indication\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Position\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRight Side\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-14 Rating @ 400V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-14 Rating @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-12 Rating @ 220V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-12 Rating @ 110V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-13 Rating @ 60V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-13 Rating @ 24V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Thermal Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 A (not switching rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.75–2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Tightening Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.2 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (H x D x W)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e85 x 69 x 8.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eApprox. 0.043 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Product Families\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB S200, SN201, F200, DS201, DS202C, DS200 (subject to installation requirements)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standards\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-5-1; GB\/T 14048.5\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eGermany (actual packaging marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4016779563826\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB S2C-H6R\u003c\/strong\u003e, manufacturer order code \u003cstrong\u003e2CDS200912R0001\u003c\/strong\u003e, is a \u003cstrong\u003eSystem pro M compact auxiliary contact\u003c\/strong\u003e designed to indicate the contact position of compatible ABB modular protective devices. It provides \u003cstrong\u003eone changeover contact (1CO \/ SPDT)\u003c\/strong\u003e and is specified for \u003cstrong\u003eright-side mounting\u003c\/strong\u003e. Manufacturer-listed compatible device families include \u003cstrong\u003eS200, SN201, F200, DS201, DS202C and DS200\u003c\/strong\u003e, subject to the applicable device and installation requirements. The auxiliary contact has an \u003cstrong\u003eAC-14 rated operational current of 1 A at 400 V AC\u003c\/strong\u003e or \u003cstrong\u003e2 A at 230 V AC\u003c\/strong\u003e. Separate DC-12 and DC-13 ratings apply depending on the circuit voltage and utilization category. The module features a compact \u003cstrong\u003e8.8 mm width\u003c\/strong\u003e, a maximum terminal tightening torque of \u003cstrong\u003e1.2 N·m\u003c\/strong\u003e, and connection capacity for conductors from \u003cstrong\u003e0.75 to 2.5 mm²\u003c\/strong\u003e. This is a contact-position indication accessory, not a standalone circuit breaker or a dedicated fault-trip signalling module. Actual product photographs show ABB-marked hardware and packaging labeled \u003cstrong\u003eS2C-H6R\u003c\/strong\u003e, with manufacturer order code \u003cstrong\u003e2CDS200912R0001\u003c\/strong\u003e and EAN \u003cstrong\u003e4016779563826\u003c\/strong\u003e. The accessory's individual catalog marking is not visible in the supplied photographs.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#FF0000;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eABB Auxiliary Contact\u003c\/strong\u003e — System pro M compact accessory for modular protective devices.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1CO \/ SPDT Changeover\u003c\/strong\u003e — Single changeover contact for auxiliary status indication.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eRight-Side Mounting\u003c\/strong\u003e — Designed for installation beside compatible ABB protective devices.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eAC-14 Operational Ratings\u003c\/strong\u003e — 1 A at 400 V AC and 2 A at 230 V AC.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eDC Control Circuit Ratings\u003c\/strong\u003e — DC-12 and DC-13 utilization ratings for specified voltage conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eCompact 8.8 mm Width\u003c\/strong\u003e — Slim auxiliary accessory for modular distribution assemblies.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eDevice Contact Position Indication\u003c\/strong\u003e — Provides auxiliary electrical feedback from the associated device.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eABB Device Compatibility\u003c\/strong\u003e — Manufacturer-listed S200, SN201, F200, DS201, DS202C and DS200 families.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#FF0000;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual product packaging and accessory photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003eS2C-H6R\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging manufacturer order code: \u003cstrong\u003e2CDS200912R0001\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging EAN barcode: \u003cstrong\u003e4016779563826\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging description: \u003cstrong\u003eAuxiliary Contact\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Package origin marking: \u003cstrong\u003eMade in Germany\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ ABB branding visible on the accessory body\u003c\/div\u003e\n        \u003cdiv\u003e✓ Accessory AC-14, DC-12 and DC-13 ratings visible\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging identity corresponds to ABB manufacturer records\u003c\/div\u003e\n        \u003cdiv\u003e✓ The accessory's individual catalog number is not visible in these photographs\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm accessory identity and installation compatibility before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#FF0000;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003eS2C-H6R\u003c\/strong\u003e, order code \u003cstrong\u003e2CDS200912R0001\u003c\/strong\u003e, is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on YINGZHOU inventory information. Actual packaging and accessory photographs are available for product verification. The \u003cstrong\u003e1CO \/ SPDT right-side auxiliary contact\u003c\/strong\u003e is offered for compatible ABB modular protective equipment. Please confirm the exact accessory configuration, compatible circuit breaker or residual-current device, operational current, application voltage, order quantity and dispatch arrangements before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eABB S2C-H6R\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 1CO \/ SPDT configuration, right-side mounting, AC-14 or DC switching ratings and compatibility before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#FF0000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other ABB industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/it\/collections\/abb\" style=\"color:#FF0000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore ABB Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"S2C-H6R","offer_id":58698206773551,"sku":"S2C-H6R","price":14.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-S2C-H6R.jpg?v=1792763916"},{"product_id":"schneider-lads2-on-delay-auxiliary-contact-block","title":"Schneider LADS2 TeSys Deca 1NO+1NC 1-30s On-Delay Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Schneider LADS2 TeSys Deca Time Delay Contact Block\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      1NO + 1NC | On Delay | 1-30s | 40 ± 15ms Switching Interval\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#3DCD58;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Packaging Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLADS2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys D \/ TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTime Delay Auxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDelay Mechanism\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTimer Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eOn Delay (On Energization)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAdjustable Time Delay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1-30 Seconds\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1 NO + 1 NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNC Contact Terminals\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e55-56 (Actual Unit Marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNO Contact Terminals\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e67-68 (Actual Unit Marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNC-to-NO Switching Interval\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40 ± 15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eStar-Delta Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Location\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eClip-On\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Product Families\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys Deca LC1D \/ CAD; TeSys F LC1F \/ CR1F (subject to compatibility)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V AC, 25-400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-15 Current @ 120V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-15 Current @ 690V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.04 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-13 Current @ 125V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.55 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDC-13 Current @ 600V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Thermal Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 A at 60°C (Ith)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V (IEC\/EN 60947-5-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL\/CSA Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Clamp Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Tightening Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.7 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1-2.5 mm² (subject to connection configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e48 x 44 x 61 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-60°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5 Million Cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFrance (actual unit and package markings)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110386103\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LADS2\u003c\/strong\u003e is a \u003cstrong\u003eTeSys D \/ TeSys Deca pneumatic time-delay auxiliary contact block\u003c\/strong\u003e designed for installation on compatible industrial contactors and control relays. It provides \u003cstrong\u003eone normally open and one normally closed contact (1NO + 1NC)\u003c\/strong\u003e with an adjustable \u003cstrong\u003e1-30 second on-delay function\u003c\/strong\u003e. The module is specifically designed for appropriate \u003cstrong\u003estar-delta motor starter applications\u003c\/strong\u003e, with a manufacturer-specified \u003cstrong\u003e40 ± 15 ms switching interval between NC contact opening and NO contact closing\u003c\/strong\u003e. The delayed switching sequence helps coordinate starter control, subject to contactor ratings and manufacturer application requirements. The module uses \u003cstrong\u003efront clip-on mounting\u003c\/strong\u003e and \u003cstrong\u003escrew clamp terminals\u003c\/strong\u003e. Compatible product families include selected \u003cstrong\u003eTeSys Deca LC1D and CAD\u003c\/strong\u003e devices and \u003cstrong\u003eTeSys F LC1F and CR1F\u003c\/strong\u003e contactors. Its conventional free-air thermal current is \u003cstrong\u003e10 A at 60°C\u003c\/strong\u003e, with operational switching current determined by utilization category and voltage. The rated insulation voltage is \u003cstrong\u003e690 V under IEC\/EN 60947-5-1\u003c\/strong\u003e. Actual supplied photographs show Schneider Electric packaging marked \u003cstrong\u003eLADS2\u003c\/strong\u003e and a matching auxiliary contact structure with \u003cstrong\u003e55-56 NC and 67-68 NO\u003c\/strong\u003e markings. The complete catalog-number marking on the individual unit is not visible in these photographs.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTeSys Deca Auxiliary Contact Block\u003c\/strong\u003e — Schneider Electric pneumatic time-delay accessory.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1-30 Second On Delay\u003c\/strong\u003e — Adjustable time-delay function for compatible contactor control circuits.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1NO + 1NC Contacts\u003c\/strong\u003e — One normally open and one normally closed auxiliary contact.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e40 ± 15 ms Switching Interval\u003c\/strong\u003e — Specified time between opening of the NC contact and closing of the NO contact.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eStar-Delta Starter Application\u003c\/strong\u003e — Designed for applicable motor starting control systems.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e690 V Insulation Rating\u003c\/strong\u003e — Rated Ui under IEC\/EN 60947-5-1.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e10 A Conventional Thermal Current\u003c\/strong\u003e — Ith at 60°C; actual switching rating depends on load conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront Clip-On Installation\u003c\/strong\u003e — Compatible with specified TeSys Deca and TeSys F devices.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eScrew Clamp Terminals\u003c\/strong\u003e — Connection arrangement for industrial auxiliary control wiring.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual product and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Main packaging catalog number: \u003cstrong\u003eLADS2\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging time delay marking: \u003cstrong\u003e1-30s\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging quantity: \u003cstrong\u003e1 Piece\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging EAN barcode: \u003cstrong\u003e3389110386103\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Actual unit carries \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e branding\u003c\/div\u003e\n        \u003cdiv\u003e✓ NC contact marking: \u003cstrong\u003e55-56\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ NO contact marking: \u003cstrong\u003e67-68\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Unit thermal current marking: \u003cstrong\u003eIth 10 A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Unit insulation voltage marking: \u003cstrong\u003eUi 690 V\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Unit standard marking: \u003cstrong\u003eIEC\/EN 60947-5-1\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging and unit marked \u003cstrong\u003eMade in France\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Main packaging model corresponds to Schneider Electric manufacturer documentation\u003c\/div\u003e\n        \u003cdiv\u003e✓ Individual unit full catalog marking is not visible in the supplied images\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm the exact unit, time-delay range, switching sequence and contactor compatibility before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#3DCD58;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLADS2\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on YINGZHOU inventory information. Actual product and packaging photographs are available for procurement verification. This \u003cstrong\u003eTeSys Deca on-delay auxiliary contact block\u003c\/strong\u003e features an adjustable \u003cstrong\u003e1-30 second time-delay range\u003c\/strong\u003e, \u003cstrong\u003e1NO + 1NC contacts\u003c\/strong\u003e and a specified \u003cstrong\u003e40 ± 15 ms NC-to-NO switching interval\u003c\/strong\u003e. For star-delta motor starter control, electrical maintenance, replacement orders, bulk purchasing or multi-brand sourcing, please confirm the associated contactor model, contact ratings, delay setting, quantity and dispatch arrangements before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSchneider LADS2\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 1-30s on-delay range, 1NO+1NC contact configuration, 40ms switching interval and compatibility before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#3DCD58;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Schneider Electric industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#3DCD58;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Schneider Electric Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LADS2","offer_id":58698502832431,"sku":"LADS2","price":34.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-LADS2-3.jpg?v=1792766631"},{"product_id":"schneider-ladn11c-auxiliary-contact-block","title":"Schneider LADN11C TeSys Deca 1NO+1NC 10A Front Auxiliary Contact Block","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Schneider LADN11C TeSys Deca Auxiliary Contact Block\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      1NO + 1NC | 10A Ith | 690V Ui | Front Mount | Instantaneous\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#3DCD58;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLADN11C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys D \/ TeSys Deca\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAuxiliary Contact Block\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1 NO + 1 NC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNO Contact Terminals\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e53-54\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNC Contact Terminals\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e61-62\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eContact Operation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eInstantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Position\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eClip-On\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Thermal Current (Ith)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e10 A at 60°C or below\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e690 V (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL \/ CSA Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e600 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V AC, 25-400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Making Capacity (AC)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e140 A, IEC Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Making Capacity (DC)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e250 A, IEC Conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Time Withstand at 60°C\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e100 A \/ 1 Second\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Time Withstand at 60°C\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e120 A \/ 500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Time Withstand at 60°C\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e140 A \/ 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFuse Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 A gG, Subject to Application\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30,000,000 Operations\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Switching Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMinimum Switching Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e17 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConnection Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Clamp Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConductor Cross-Section\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1-2.5 mm², According to Terminal Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.03 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-5°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-60°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Operating Altitude\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApplicable Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (Actual Unit Marking)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePackaging Quantity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 Piece\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePackaging EAN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6970452002010\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LADN11C\u003c\/strong\u003e is a \u003cstrong\u003eTeSys D \/ TeSys Deca auxiliary contact block\u003c\/strong\u003e designed for auxiliary switching in compatible industrial contactor and control circuits. It features \u003cstrong\u003eone normally open and one normally closed contact (1NO + 1NC)\u003c\/strong\u003e with \u003cstrong\u003einstantaneous operation\u003c\/strong\u003e. The normally open contact uses terminals \u003cstrong\u003e53-54\u003c\/strong\u003e, while the normally closed contact uses terminals \u003cstrong\u003e61-62\u003c\/strong\u003e. This contact numbering is confirmed by Schneider Electric for the LADN11C model and must not be confused with the different contact numbering of LADN11CS004. The contact block is designed for \u003cstrong\u003efront clip-on installation\u003c\/strong\u003e on compatible TeSys equipment and uses \u003cstrong\u003escrew clamp terminals\u003c\/strong\u003e. Its conventional free-air thermal current is rated at \u003cstrong\u003e10 A at temperatures up to 60°C\u003c\/strong\u003e, and its rated insulation voltage is \u003cstrong\u003e690 V under IEC 60947-5-1\u003c\/strong\u003e. Schneider Electric specifies a mechanical durability of \u003cstrong\u003e30 million operations\u003c\/strong\u003e. The LADN11C does not contain an independent power coil or an adjustable timer; the contacts operate mechanically with the associated contactor. Actual supplied photographs show \u003cstrong\u003eLADN11C\u003c\/strong\u003e on both the product nameplate and packaging, with matching electrical and contact terminal markings. Before ordering, please confirm the associated contactor model, control circuit ratings and required quantity.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTeSys Deca Auxiliary Contact Block\u003c\/strong\u003e — Schneider Electric LADN11C for compatible contactor assemblies.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1NO + 1NC Contacts\u003c\/strong\u003e — One normally open and one normally closed auxiliary contact.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eInstantaneous Contact Operation\u003c\/strong\u003e — Mechanical auxiliary switching without an adjustable time-delay function.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e10 A Conventional Thermal Current\u003c\/strong\u003e — Rated Ith under the manufacturer's specified conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e690 V Insulation Rating\u003c\/strong\u003e — Rated Ui according to IEC 60947-5-1.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eFront Clip-On Mounting\u003c\/strong\u003e — Designed for installation on compatible TeSys equipment.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eDefined Contact Terminals\u003c\/strong\u003e — 53-54 NO and 61-62 NC, as identified by Schneider Electric.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eScrew Clamp Connections\u003c\/strong\u003e — Electrical connection arrangement for auxiliary control wiring.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e30 Million Mechanical Operations\u003c\/strong\u003e — Manufacturer-specified mechanical durability.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual contact block and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product body catalog number: \u003cstrong\u003eLADN11C\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003eLADN11C\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product and packaging exact model numbers match\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product contact arrangement: \u003cstrong\u003e1 NO + 1 NC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Normally open contact terminals: \u003cstrong\u003e53-54\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Normally closed contact terminals: \u003cstrong\u003e61-62\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product thermal current marking: \u003cstrong\u003eIth 10 A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product rated insulation marking: \u003cstrong\u003eUi 690 V\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product standard marking: \u003cstrong\u003eIEC 60947-5-1\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging product family: \u003cstrong\u003eTeSys Control\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging quantity: \u003cstrong\u003e1 Piece\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging EAN: \u003cstrong\u003e6970452002010\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product country of manufacture: \u003cstrong\u003eMade in China\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Exact model and key ratings correspond to Schneider Electric documentation\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm contactor compatibility, auxiliary circuit ratings and quantity before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#3DCD58;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLADN11C\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on YINGZHOU inventory information. Actual product and packaging photographs are available for exact-model verification. This \u003cstrong\u003eTeSys Deca auxiliary contact block\u003c\/strong\u003e provides \u003cstrong\u003e1NO + 1NC instantaneous contacts\u003c\/strong\u003e, with \u003cstrong\u003e53-54 NO\u003c\/strong\u003e and \u003cstrong\u003e61-62 NC\u003c\/strong\u003e terminal identification. The device is specified with a \u003cstrong\u003e10 A conventional thermal current\u003c\/strong\u003e and \u003cstrong\u003e690 V rated insulation voltage\u003c\/strong\u003e. For industrial contactor maintenance, replacement orders, electrical control panels, multiple-unit purchasing or project sourcing, please confirm the required auxiliary contact arrangement, compatible contactor model, quantity and dispatch arrangements before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSchneider LADN11C\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 1NO+1NC configuration, 53-54\/61-62 terminal numbering, contactor compatibility and application requirements before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/it\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#3DCD58;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Schneider Electric industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/it\/collections\/schneider\" style=\"color:#3DCD58;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Schneider Electric Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LADN11C","offer_id":58703048900911,"sku":"LADN11C","price":2.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-LADN11C-TeSys-Deca-1NO1NC-10A-Front-Auxiliary-Contact-Block.jpg?v=1792814349"}],"url":"https:\/\/szyingzhou.com\/it\/collections\/auxiliary-contacts.oembed","provider":"YingZhou Automatization","version":"1.0","type":"link"}