{"product_id":"schneider-le1m35m712-tesys-le-motor-starter","title":"Schneider LE1M35M712 TeSys LE 3.7-5.5A 220V AC Coil IP65 Enclosed DOL Motor Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Schneider Electric LE1M35M712 TeSys LE Motor Starter\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      3.7–5.5A | 220V AC Coil | 2.2kW @ 400V | IP65 | DOL Starter\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#3DCD58;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLE1M35M712\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys LE\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLE1M\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEnclosed Direct-On-Line (DOL) Motor Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eStandard Motor Starting\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Control Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNon-Reversing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUtilisation Category\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC-3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNumber of Main Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eElectrical System\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree-Phase Motor Control\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Adjustment Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3.7–5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 220\/230V AC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 240V AC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 380\/400V AC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 415V AC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2.2 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage — Official\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e220V AC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Marking — Actual Device\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e230V AC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntegrated Contactor\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLC1K Series\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Relay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLR2K Series\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNeutral Terminal\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEarth Terminal\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStart Control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eGreen Push Button (I)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStop \/ Reset Control\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRed Push Button (O)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eLocal Signalling\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYellow Operating LED\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSurface \/ Wall Mounting, Screw Fixing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSelf-Extinguishing ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEnclosure Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP65 — IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCable Entry\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTop and Bottom Knockout Positions\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Cable Entry Sizes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePg 13 \/ Pg 16 \/ Pg 21 \/ ISO20 \/ ISO25\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverall Width\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e78 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverall Height\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverall Depth\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e108 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−5 to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Environment\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eStandard Industrial Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExternal Short-Circuit Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRequired for Applicable Coordination\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Overload Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIntegrated Thermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Wiring\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMust Follow Manufacturer Wiring Diagram\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCzech Republic (Photographed Label)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LE1M35M712\u003c\/strong\u003e is a \u003cstrong\u003eTeSys LE enclosed Direct-On-Line (DOL) motor starter\u003c\/strong\u003e designed for compatible three-phase, non-reversing motor control applications. This industrial starter combines an integrated \u003cstrong\u003eLC1K contactor\u003c\/strong\u003e and \u003cstrong\u003eLR2K thermal overload relay\u003c\/strong\u003e to provide direct motor starting and adjustable overload protection in a protective enclosure. The thermal overload adjustment range is \u003cstrong\u003e3.7–5.5A\u003c\/strong\u003e. The manufacturer specifies an \u003cstrong\u003eAC-3 motor power rating of 2.2kW at 380\/400V AC\u003c\/strong\u003e, \u003cstrong\u003e2.2kW at 415V AC\u003c\/strong\u003e, \u003cstrong\u003e1.1kW at 220\/230V AC\u003c\/strong\u003e and \u003cstrong\u003e0.75kW at 240V AC\u003c\/strong\u003e. The \u003cstrong\u003eM7 control coil configuration\u003c\/strong\u003e is identified by Schneider Electric as \u003cstrong\u003e220V AC, 50\/60Hz\u003c\/strong\u003e; the photographed device nameplate carries a \u003cstrong\u003e230V AC, 50\/60Hz\u003c\/strong\u003e marking, so the actual control supply must be checked against the manufacturer's voltage tolerances and installation instructions. The LE1M35M712 incorporates a \u003cstrong\u003egreen Start push button\u003c\/strong\u003e, \u003cstrong\u003ered Stop\/Reset push button\u003c\/strong\u003e and \u003cstrong\u003eyellow operating indicator\u003c\/strong\u003e for convenient local motor operation. Its \u003cstrong\u003eIP65-rated enclosure\u003c\/strong\u003e is designed for surface mounting with suitable cable-entry sealing and installation arrangements. The enclosure dimensions are \u003cstrong\u003e78 × 160 × 108mm\u003c\/strong\u003e, and the product weight is approximately \u003cstrong\u003e0.6kg\u003c\/strong\u003e. The starter complies with \u003cstrong\u003eIEC 60947-4-1\u003c\/strong\u003e and requires compatible external short-circuit protection according to the specified coordination requirements. The supplied actual photographs show the exact \u003cstrong\u003eLE1M35M712\u003c\/strong\u003e model number on both the device nameplate and original packaging label, together with front operator controls and the electrical wiring diagram. Buyers should confirm the motor's nameplate current, operating voltage, coil supply, installation environment and short-circuit protection requirements before ordering.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTeSys LE Enclosed DOL Starter\u003c\/strong\u003e — Schneider Electric direct-on-line starter for compatible three-phase, non-reversing motors.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e3.7–5.5A Adjustable Overload Protection\u003c\/strong\u003e — Integrated LR2K thermal overload relay for motor current protection.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e220V AC Control Coil\u003c\/strong\u003e — Manufacturer-specified 50\/60Hz control circuit for the M7 coil configuration.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e2.2kW Motor Rating at 400V AC\u003c\/strong\u003e — Suitable for matching AC-3 three-phase motor applications.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIntegrated Contactor and Overload Relay\u003c\/strong\u003e — LC1K contactor and LR2K overload relay within one enclosed starter.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIP65 Protective Enclosure\u003c\/strong\u003e — Protective housing designed for surface mounting and properly sealed cable entry.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eConvenient Front Controls\u003c\/strong\u003e — Green Start push button, red Stop\/Reset push button and yellow operating indicator.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Schneider Electric starter and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Device nameplate catalog number: \u003cstrong\u003eLE1M35M712\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003eLE1M35M712\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Device and packaging identify the same exact model\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer product family: \u003cstrong\u003eTeSys LE\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product type: \u003cstrong\u003eDirect-On-Line Motor Starter\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front green Start push button photographed\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front red Stop\/Reset push button photographed\u003c\/div\u003e\n        \u003cdiv\u003e✓ Yellow operating indicator visible on the front panel\u003c\/div\u003e\n        \u003cdiv\u003e✓ Thermal overload adjustment range: \u003cstrong\u003e3.7–5.5A\u003c\/strong\u003e (Manufacturer Data)\u003c\/div\u003e\n        \u003cdiv\u003e✓ Motor power rating: \u003cstrong\u003e2.2kW at 380\/400V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Motor power rating: \u003cstrong\u003e2.2kW at 415V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Motor power rating: \u003cstrong\u003e1.1kW at 220\/230V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Motor power rating: \u003cstrong\u003e0.75kW at 240V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Device nameplate shows \u003cstrong\u003eIP65\u003c\/strong\u003e protection\u003c\/div\u003e\n        \u003cdiv\u003e✓ Device coil marking: \u003cstrong\u003e230V AC, 50\/60Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer nominal coil designation: \u003cstrong\u003e220V AC, 50\/60Hz\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Side electrical wiring diagram photographed\u003c\/div\u003e\n        \u003cdiv\u003e✓ Original packaging quantity marking: \u003cstrong\u003ex1\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Country of manufacture marking: \u003cstrong\u003eMade in Czech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Power-on and motor-start functional testing have not been demonstrated\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm motor current, coil voltage and short-circuit protection before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#3DCD58;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLE1M35M712\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory information. This TeSys LE enclosed DOL motor starter is offered for compatible three-phase motor control, industrial maintenance and direct-on-line starter replacement applications. The supplied actual photographs show the exact model number on the device nameplate and original packaging, together with front operator controls and the side electrical wiring diagram. The starter features \u003cstrong\u003e3.7–5.5A adjustable thermal overload protection\u003c\/strong\u003e, a manufacturer-designated \u003cstrong\u003e220V AC 50\/60Hz control coil\u003c\/strong\u003e and a \u003cstrong\u003e2.2kW motor rating at 380\/400V AC under AC-3 conditions\u003c\/strong\u003e. The photographed unit carries a \u003cstrong\u003e230V AC coil marking\u003c\/strong\u003e. The device incorporates an LC1K contactor and LR2K thermal overload relay within an IP65-rated enclosure. Please confirm the motor's rated current, control-circuit voltage, external short-circuit protective device, installation requirements, exact unit condition and dispatch arrangements before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSchneider LE1M35M712\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and industrial motor starter sourcing. Please confirm the 3.7–5.5A overload range, 220V AC nominal control coil, motor power rating and installation requirements before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/id\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#3DCD58;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Schneider Electric industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/id\/collections\/schneider\" style=\"color:#3DCD58;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Schneider Electric Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LE1M35M712","offer_id":59021087441199,"sku":"LE1M35M712","price":134.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-LE1M35M712-TeSys-LE-3_7-5_5A-220V-AC-Coil-IP65-Enclosed-DOL-Motor-Starter.jpg?v=1795507849","url":"https:\/\/szyingzhou.com\/id\/products\/schneider-le1m35m712-tesys-le-motor-starter","provider":"YingZhou Automatization","version":"1.0","type":"link"}