{"product_id":"schneider-lr2k0306-thermal-overload-relay","title":"Schneider LR2K0306 TeSys K 0.8-1.2A Thermal Overload Relay","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Schneider Electric LR2K0306 TeSys K Thermal Overload Relay\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      0.8-1.2A | Class 10A | 1NO + 1NC | Motor Protection | TeSys K\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#3DCD58;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLR2K0306\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys K\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys LRK\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLR2K\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDifferential Thermal Overload Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRelay Application\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Overload Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Technology\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThermal Bimetallic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Protection Adjustment Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.8-1.2A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Class\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eClass 10A (IEC 60947-4-1)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Failure Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Unbalance Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC \/ DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to 400Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLC1K \/ LC7K \/ LP1K \/ LP4K\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Arrangement\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUnder Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeparate Mounting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRail or Plate with Specific Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeparate Mounting Accessory\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLA7K0064 (Sold Separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAuxiliary Contact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1NO + 1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Open Contact\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e97-98 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNormally Closed Contact\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e95-96 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Modes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eManual \/ Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Mode Selector\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eH (Manual) \/ A (Automatic)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTest Function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRed Trip Test Button\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStop \/ Manual Reset\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBlue Pushbutton\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTrip Indication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYellow Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui), IEC\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui), CSA\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e600V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage, Power Circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to 690V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage, AC-15 Signalling\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage, DC-13 Signalling\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e250V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConventional Free Air Thermal Current (Ith)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A, Signalling Circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAssociated Signalling Fuse\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6A gG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Dissipation per Pole\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Clamp Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Tightening Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.3 N·m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSolid Conductor Capacity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.5-4mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFlexible Conductor Without Ferrule\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.75-4mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFlexible Conductor With Ferrule\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.34-2.5mm², Single Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP2X\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature Without Derating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-20°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature With Derating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-30°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Altitude Without Derating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Height\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e58mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Width\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Depth\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e65mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.145kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Protection Standard\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUL \/ CSA \/ UKCA (Manufacturer Datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110230420\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMade in Czech Republic (Photo Label)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LR2K0306\u003c\/strong\u003e is a \u003cstrong\u003eTeSys K \/ TeSys LRK differential thermal overload relay\u003c\/strong\u003e designed to protect industrial motors against overload conditions and phase failure. It features an adjustable thermal protection range of \u003cstrong\u003e0.8-1.2A\u003c\/strong\u003e and a \u003cstrong\u003eClass 10A tripping characteristic\u003c\/strong\u003e conforming to IEC 60947-4-1. The relay uses a thermal bimetallic protection mechanism with phase failure sensitivity and provides \u003cstrong\u003eone normally open (1NO) and one normally closed (1NC) auxiliary contact\u003c\/strong\u003e for signalling and control functions. The device includes a \u003cstrong\u003emanual\/automatic reset selector\u003c\/strong\u003e, red trip test button, blue stop\/manual reset button and yellow trip indicator. It is designed for direct mounting under compatible \u003cstrong\u003eTeSys K contactors\u003c\/strong\u003e, including LC1K, LC7K, LP1K and LP4K families. Separate mounting is also possible with specific accessories, such as the LA7K0064 terminal block. The compact relay measures \u003cstrong\u003e45 x 58 x 65mm (W x H x D)\u003c\/strong\u003e and features screw clamp terminals and IP2X protection. The supplied actual product and packaging photographs confirm the exact \u003cstrong\u003eLR2K0306\u003c\/strong\u003e model and \u003cstrong\u003e0.8-1.2A\u003c\/strong\u003e current adjustment range. The thermal setting must be selected according to the motor nameplate current, and separate short-circuit protection must be provided in the motor circuit.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTeSys K Differential Thermal Overload Relay\u003c\/strong\u003e — Schneider Electric motor overload protection device for industrial control applications.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e0.8-1.2A Adjustable Protection\u003c\/strong\u003e — Adjustable thermal current setting for motors with compatible full-load current ratings.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eClass 10A Thermal Tripping\u003c\/strong\u003e — Overload tripping characteristic conforming to IEC 60947-4-1.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003ePhase Failure Sensitivity\u003c\/strong\u003e — Differential bimetallic protection against phase failure and load unbalance conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1NO + 1NC Auxiliary Contacts\u003c\/strong\u003e — Integrated contacts for motor protection signalling and control circuits.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eManual and Automatic Reset\u003c\/strong\u003e — Includes a selectable reset mode, trip test control and stop\/manual reset button.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eTeSys K Contactor Compatibility\u003c\/strong\u003e — Suitable for direct mounting with compatible LC1K, LC7K, LP1K and LP4K contactor families.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#3DCD58;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual relay front, side and manufacturer packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer identification: \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Relay front model: \u003cstrong\u003eLR2K0306\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging model: \u003cstrong\u003eLR2K0306\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer thermal protection adjustment range: \u003cstrong\u003e0.8-1.2A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer overload class: \u003cstrong\u003eClass 10A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front auxiliary contact markings: \u003cstrong\u003e97-98 NO and 95-96 NC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Front control functions: \u003cstrong\u003eTrip Test, Stop\/Reset and Manual\/Automatic Reset Selector\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Side label identifies \u003cstrong\u003eMade in Czech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product and packaging identification is consistent with the official LR2K0306 specifications\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm motor full-load current, compatible contactor and required installation accessories before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#3DCD58;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLR2K0306\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory information. This \u003cstrong\u003eTeSys K differential thermal overload relay\u003c\/strong\u003e is available for industrial motor protection, electrical maintenance, replacement and project sourcing inquiries. The supplied actual photographs confirm the exact \u003cstrong\u003eLR2K0306\u003c\/strong\u003e model and its adjustable \u003cstrong\u003e0.8-1.2A\u003c\/strong\u003e thermal protection range. The relay is designed for use with compatible TeSys K contactors and requires appropriate upstream short-circuit protection. Please confirm the motor nameplate current, compatible contactor, required accessories, order quantity and dispatch arrangements before completing an order.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSchneider Electric LR2K0306\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 0.8-1.2A thermal setting range, Class 10A protection, 1NO+1NC auxiliary contacts and compatible motor starter configuration before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/es\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#3DCD58;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Schneider Electric industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/es\/collections\/schneider\" style=\"color:#3DCD58;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Schneider Electric Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LR2K0306","offer_id":58791675199791,"sku":"LR2K0306","price":27.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-LR2K0306-TeSys-K-0_8-1_2A-Thermal-Overload-Relay.jpg?v=1793947092","url":"https:\/\/szyingzhou.com\/es\/products\/schneider-lr2k0306-thermal-overload-relay","provider":"YingZhou Automatization","version":"1.0","type":"link"}