{"title":"Schneider Electric Control Units \u0026 TeSys U Motor Protection","description":"\n\u003cdiv style=\"width:100%;margin:0;\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"\n    background:#3DCD58;\n    border-radius:12px;\n    padding:24px 28px 22px;\n    color:#FFFFFF;\n  \"\u003e\n\n    \u003cdiv style=\"\n      margin:0 0 6px;\n      font-size:10.5px;\n      line-height:1.4;\n      font-weight:700;\n      letter-spacing:1.15px;\n      text-transform:uppercase;\n      color:#FFFFFF;\n    \"\u003e\n      SCHNEIDER ELECTRIC CONTROL UNITS\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"\n      margin:0 0 7px;\n      color:#FFFFFF;\n      font-size:25px;\n      line-height:1.3;\n      font-weight:700;\n    \"\u003e\n      TeSys U Control Units \u0026amp; Motor Starter Protection\n    \u003c\/h2\u003e\n\n    \u003cp style=\"\n      margin:0;\n      max-width:850px;\n      color:#FFFFFF;\n      font-size:14px;\n      line-height:1.6;\n    \"\u003e\n      Explore Schneider Electric TeSys U control\n      units for industrial motor starter protection,\n      electrical maintenance and motor control\n      applications. Discover standard and advanced\n      protection units, single-phase control units,\n      magnetic protection modules and legacy\n      multifunction units for compatible TeSys U\n      motor starter assemblies.\n    \u003c\/p\u003e\n\n    \u003c!-- PRODUCT RANGE --\u003e\n    \u003cdiv style=\"\n      margin-top:16px;\n      padding-top:13px;\n      border-top:1px solid rgba(255,255,255,.35);\n    \"\u003e\n\n      \u003cdiv style=\"\n        margin-bottom:5px;\n        font-size:10px;\n        line-height:1.4;\n        font-weight:700;\n        letter-spacing:.9px;\n        text-transform:uppercase;\n        color:#FFFFFF;\n      \"\u003e\n        PRODUCT RANGE\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"\n        font-size:12.5px;\n        line-height:1.6;\n        font-weight:700;\n        color:#FFFFFF;\n      \"\u003e\n        Standard Control Units\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Advanced Motor Protection Units\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Single-Phase Control Units\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Magnetic Protection Units\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Legacy Multifunction Control Units\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- PRODUCT FAMILIES --\u003e\n    \u003cdiv style=\"margin-top:11px;\"\u003e\n\n      \u003cdiv style=\"\n        margin-bottom:4px;\n        font-size:10px;\n        line-height:1.4;\n        font-weight:700;\n        letter-spacing:.9px;\n        text-transform:uppercase;\n        color:#FFFFFF;\n      \"\u003e\n        PRODUCT FAMILIES\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"\n        font-size:12px;\n        line-height:1.6;\n        color:#FFFFFF;\n      \"\u003e\n        LUCA Standard ·\n        LUCB Advanced Class 10 ·\n        LUCC Single-Phase Class 10 ·\n        LUCD Advanced Class 20 ·\n        LUCL Magnetic Only ·\n        LUCM Legacy Multifunction\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- BUYER ASSISTANCE --\u003e\n  \u003cdiv style=\"\n    display:flex;\n    flex-wrap:wrap;\n    align-items:center;\n    justify-content:space-between;\n    gap:6px 18px;\n    margin-top:8px;\n    padding:10px 15px;\n    background:#f7f9fb;\n    border:1px solid #e8edf1;\n    border-radius:7px;\n    font-size:12.5px;\n    line-height:1.55;\n    color:#555555;\n  \"\u003e\n\n    \u003cdiv\u003e\n      \u003cstrong style=\"color:#222222;\"\u003e\n        Need a specific Schneider Electric control unit?\n      \u003c\/strong\u003e\n      Send us the\n      \u003cstrong style=\"color:#222222;\"\u003e\n        model\/part number + quantity\n      \u003c\/strong\u003e.\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"color:#555555;white-space:nowrap;\"\u003e\n      Availability\n      \u003cspan style=\"margin:0 6px;color:#b7bec4;\"\u003e·\u003c\/span\u003e\n      Lead Time\n      \u003cspan style=\"margin:0 6px;color:#b7bec4;\"\u003e·\u003c\/span\u003e\n      Quotation\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","products":[{"product_id":"schneider-luca05bl-control-unit","title":"Schneider Electric LUCA05BL TeSys U 1.25-5A 24V DC Class 10 Standard Control Unit","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric LUCA05BL TeSys U Standard Control Unit\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      1.25–5A | 24V DC | Class 10 | 3-Phase Motor Protection | TeSys U\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FAF3;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n\n    \u003cstrong style=\"color:#26853A;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Exact Model Verified on Packaging\n    \u003c\/span\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FAF3;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUCA05BL\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys U \/ TeSys Ultra\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eStandard Control Unit\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Control \/ Motor Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSpecific Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBasic Protection for Motor Starters\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eLoad Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree-Phase Self-Cooled Motor\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Current Adjustment Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1.25–5 A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage (Uc)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage Limits\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20–27 V DC in Operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Drop-Out Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e14.5 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eClass 10\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Compensation Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOvercurrent Tripping Threshold\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e14.2 × Ir ±20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eManual Reset\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverload Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible TeSys U Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Circuit Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible TeSys U Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Failure Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Imbalance Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEarth Fault Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEquipment Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Rated Operational Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to 690 V AC with Compatible Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUtilisation Categories\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC-41 \/ AC-43 \/ AC-44\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 400–440V AC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1.5 kW at 50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 500V AC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2.2 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 690V AC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Power Bases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUB12 \/ LUB32 \/ LUB38\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAdditional Compatible Power Bases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUB120 \/ LUB320 \/ LUB380\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Reversing Bases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLU2B12BL \/ LU2B32BL \/ LU2B38BL\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Closing Current with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e130 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Sealed Current with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Closing Current with LUB32\/LUB38\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e220 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Sealed Current with LUB32\/LUB38\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e80 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Heat Dissipation with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Heat Dissipation with LUB32\/LUB38\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Opening Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e35 ms with Listed Compatible Bases\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Closing Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e70 ms with Listed Compatible Bases\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V IEC \/ 600V UL \u0026amp; CSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 kV\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSafe Circuit Separation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e400V SELV, Manufacturer Specified\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePlug-in, Front Face\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWidth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHeight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e66 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDepth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.135 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatibility Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Panel \/ Wired Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Outside Connection Zone\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP40\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-40°C to +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Operating Altitude\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2,000 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandards\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-6-2; UL 60947-4-1; CSA C22.2 No. 60947-4-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eGTIN \/ EAN\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110363838\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LUCA05BL\u003c\/strong\u003e\n      is a standard control unit from the\n      \u003cstrong\u003eTeSys U \/ TeSys Ultra\u003c\/strong\u003e\n      modular motor starter range.\n      Designed for three-phase motor control and protection,\n      it provides an adjustable\n      \u003cstrong\u003e1.25–5A motor current range\u003c\/strong\u003e,\n      a \u003cstrong\u003e24V DC control circuit\u003c\/strong\u003e\n      and \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e.\n      When installed in a compatible TeSys U starter assembly,\n      the control unit supports overload, short-circuit,\n      phase failure, phase imbalance and\n      equipment earth fault protection.\n      It supports motor applications rated at\n      \u003cstrong\u003e1.5kW at 400–440V AC\u003c\/strong\u003e\n      under the manufacturer's specified conditions.\n      Its electronic current adjustment\n      and front plug-in modular construction\n      support installation and maintenance.\n      \u003cstrong\u003eLUCA05BL is a standard control unit only,\n      not a complete motor starter.\u003c\/strong\u003e\n      A compatible power base must be selected separately.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FAF3;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e\n          for compatible modular motor starter assemblies\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e1.25–5A adjustable motor current range\u003c\/strong\u003e\n          for three-phase motor protection\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e24V DC control circuit\u003c\/strong\u003e\n          with a manufacturer-specified\n          20–27V DC operating range\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e\n          with manual reset\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e1.5kW motor rating at 400–440V AC\u003c\/strong\u003e\n          under specified three-phase operating conditions\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eBasic motor protection functions\u003c\/strong\u003e\n          including overload and short-circuit protection\n          with a compatible power base\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003ePhase failure and imbalance protection\u003c\/strong\u003e\n          with equipment earth fault protection\n        \u003c\/li\u003e\n\n        \u003cli\u003e\n          \u003cstrong\u003eFront plug-in modular design\u003c\/strong\u003e\n          for compatible TeSys U power bases\n        \u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E9DA;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Actual product and Schneider packaging photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Exact model \u003cstrong\u003eLUCA05BL\u003c\/strong\u003e\n          visible on the packaging label\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          \u003cstrong\u003e1.25–5A\u003c\/strong\u003e current range\n          and \u003cstrong\u003e24V DC\u003c\/strong\u003e marking visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Schneider branding, packaging barcode,\n          country of origin and package quantity x1 visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model, current range,\n          control voltage and compatible\n          TeSys U power base before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#26853A;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLUCA05BL\u003c\/strong\u003e\n        is currently reported in stock.\n        Actual product and packaging photographs\n        are available for buyer verification.\n        This \u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e\n        features a \u003cstrong\u003e1.25–5A adjustable motor current range\u003c\/strong\u003e,\n        \u003cstrong\u003e24V DC control voltage\u003c\/strong\u003e,\n        \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e\n        and a manufacturer-specified\n        \u003cstrong\u003e1.5kW motor rating at 400–440V AC\u003c\/strong\u003e\n        in a compatible starter configuration.\n        \u003cstrong\u003eThis listing is for the control unit only.\u003c\/strong\u003e\n        Please confirm the exact model,\n        motor rated current, control voltage,\n        compatible starter power base\n        and required quantity before purchasing.\n        Contact our team for international\n        shipping arrangements.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric LUCA05BL\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#26853A;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/collections\/schneider\" style=\"color:#26853A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LUCA05BL","offer_id":52318303584559,"sku":"LUCA05BL","price":84.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-LUCA05BL-TeSys-U-1_25-5A-24V-DC-Class-10-Standard-Control-Unit.jpg?v=1792345520"},{"product_id":"schneider-luca12bl-control-unit","title":"Schneider Electric LUCA12BL TeSys U 3-12A 24V DC Class 10 Standard Control Unit","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric LUCA12BL TeSys U Standard Control Unit\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      3–12A | 24V DC | Class 10 | 3-Phase Motor Protection | TeSys U\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FAF3;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n\n    \u003cstrong style=\"color:#26853A;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Exact Model Verified on Packaging\n    \u003c\/span\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FAF3;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUCA12BL\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys U \/ TeSys Ultra\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eStandard Control Unit\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Control \/ Motor Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSpecific Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBasic Protection for Motor Starters\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eLoad Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree-Phase Self-Cooled Motor\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Current Adjustment Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3–12 A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage (Uc)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage Limits\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20–27 V DC in Operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eClass 10\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Compensation Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOvercurrent Tripping Threshold\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e14.2 × Ir ±20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Circuit Protection Setting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e13 × Irmax in Compatible Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eManual Reset\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverload Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible TeSys U Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Circuit Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible TeSys U Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Failure Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Imbalance Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEarth Fault Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEquipment Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Rated Operational Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to 690 V AC with Compatible Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUtilisation Categories\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC-41 \/ AC-43 \/ AC-44\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 400–440V AC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e5.5 kW at 50\/60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 500V AC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5.5 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 690V AC\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e9 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Power Bases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUB12 \/ LUB32 \/ LUB38\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Closing Current with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e130 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Sealed Current with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Closing Current with LUB32\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e220 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Sealed Current with LUB32\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e80 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Heat Dissipation with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Heat Dissipation with LUB32\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Opening Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e35 ms with LUB12 \/ LUB32\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Closing Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e70 ms with LUB12 \/ LUB32\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V IEC \/ 600V UL \u0026amp; CSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 kV\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePlug-in, Front Face\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWidth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHeight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e66 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDepth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.135 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatibility Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Panel \/ Wired Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Outside Connection Zone\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP40\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-40°C to +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Operating Altitude\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2,000 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandards in Manufacturer Datasheet\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC\/EN 60947-6-2; UL 508; CSA C22.2 No. 14\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eGTIN \/ EAN\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110363845\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LUCA12BL\u003c\/strong\u003e\n      is a standard control unit from the\n      \u003cstrong\u003eTeSys U \/ TeSys Ultra\u003c\/strong\u003e\n      modular motor starter range.\n      Designed for three-phase motor control and protection,\n      it provides an adjustable\n      \u003cstrong\u003e3–12A motor current range\u003c\/strong\u003e,\n      a \u003cstrong\u003e24V DC control circuit\u003c\/strong\u003e\n      and \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e.\n      When installed in a compatible TeSys U starter assembly,\n      the control unit supports overload, short-circuit,\n      phase failure, phase imbalance and\n      equipment earth fault protection.\n      It supports motor applications rated at\n      \u003cstrong\u003e5.5kW at 400–440V AC\u003c\/strong\u003e\n      under the manufacturer's specified conditions.\n      Its electronic current adjustment\n      and front plug-in modular construction\n      support installation and maintenance.\n      \u003cstrong\u003eLUCA12BL is a standard control unit only,\n      not a complete motor starter.\u003c\/strong\u003e\n      A compatible power base must be selected separately.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FAF3;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e\n          for compatible modular motor starter assemblies\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e3–12A adjustable motor current range\u003c\/strong\u003e\n          for three-phase motor protection\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e24V DC control circuit\u003c\/strong\u003e\n          with a manufacturer-specified\n          20–27V DC operating range\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e\n          with manual reset\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e5.5kW motor rating at 400–440V AC\u003c\/strong\u003e\n          under specified three-phase operating conditions\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eBasic motor protection functions\u003c\/strong\u003e\n          including overload and short-circuit protection\n          with a compatible power base\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003ePhase failure and imbalance protection\u003c\/strong\u003e\n          with equipment earth fault protection\n        \u003c\/li\u003e\n\n        \u003cli\u003e\n          \u003cstrong\u003eFront plug-in modular design\u003c\/strong\u003e\n          for compatible TeSys U power bases\n        \u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E9DA;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Actual product and Schneider packaging photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Exact model \u003cstrong\u003eLUCA12BL\u003c\/strong\u003e\n          visible on the packaging label\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          \u003cstrong\u003e3–12A\u003c\/strong\u003e current range\n          and \u003cstrong\u003e24V DC\u003c\/strong\u003e marking visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Schneider branding, packaging barcode,\n          country of origin and package quantity x1 visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model, current range,\n          control voltage and compatible\n          TeSys U power base before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#26853A;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLUCA12BL\u003c\/strong\u003e\n        is currently reported in stock.\n        Actual product and packaging photographs\n        are available for buyer verification.\n        This \u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e\n        features a \u003cstrong\u003e3–12A adjustable motor current range\u003c\/strong\u003e,\n        \u003cstrong\u003e24V DC control voltage\u003c\/strong\u003e,\n        \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e\n        and a manufacturer-specified\n        \u003cstrong\u003e5.5kW motor rating at 400–440V AC\u003c\/strong\u003e\n        in a compatible starter configuration.\n        \u003cstrong\u003eThis listing is for the control unit only.\u003c\/strong\u003e\n        Please confirm the exact model,\n        motor rated current, control voltage,\n        compatible starter power base\n        and required quantity before purchasing.\n        Contact our team for international\n        shipping arrangements.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric LUCA12BL\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#26853A;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/collections\/schneider\" style=\"color:#26853A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LUCA12BL","offer_id":52318313709871,"sku":"LUCA12BL","price":94.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-LUCA12BL-TeSys-U-3-12A-24V-DC-Class-10-Standard-Control-Unit.jpg?v=1792345529"},{"product_id":"schneider-lucax6bl-control-unit","title":"Schneider Electric LUCA1XBL TeSys U 0.35-1.4A 24V DC Class 10 Standard Control Unit","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric LUCA1XBL TeSys U Standard Control Unit\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      0.35–1.4A | 24V DC | Class 10 | Three-Phase Motor Protection | TeSys U\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FAF3;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n\n    \u003cstrong style=\"color:#26853A;\"\u003e\n      ✓ IN STOCK\n    \u003c\/strong\u003e\n\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Schneider Electric\n       |  Exact Model LUCA1XBL\n    \u003c\/span\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FAF3;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUCA1XBL\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys U \/ TeSys Ultra\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eStandard Control Unit\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Control \/ Motor Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSpecific Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBasic Protection for Motor Starters\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eLoad Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree-Phase Self-Cooled Motor\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Current Adjustment Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e0.35–1.4 A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Voltage Limits\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20–27 V DC in Operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eClass 10\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Compensation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverload Tripping Threshold\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e14.2 × Ir ±20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eManual\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverload Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible TeSys U Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort Circuit Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible TeSys U Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Failure Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Imbalance Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEarth Fault Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEquipment Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to 690 V AC with Compatible Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUtilisation Categories\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC-41 \/ AC-43 \/ AC-44\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 400–440V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.25 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Power Bases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUB12 \/ LUB32 \/ LUB38\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Closing Current with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e130 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Sealed Current with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Heat Dissipation with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Time with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e35 ms Opening \/ 70 ms Closing\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690V IEC \/ 600V UL \u0026amp; CSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 kV\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePlug-in, Front Face\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45 × 66 × 60 mm (W × H × D)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.135 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIP Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20 \/ IP40, Depending on Surface\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-40°C to +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Altitude\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2,000 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110363821\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LUCA1XBL\u003c\/strong\u003e\n      is a standard control unit from the\n      \u003cstrong\u003eTeSys U \/ TeSys Ultra\u003c\/strong\u003e motor starter range.\n      Designed for three-phase motor control and protection,\n      it provides an adjustable\n      \u003cstrong\u003e0.35–1.4A motor current range\u003c\/strong\u003e,\n      \u003cstrong\u003e24V DC control voltage\u003c\/strong\u003e\n      and \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e.\n      When combined with a compatible TeSys U power base,\n      the control unit contributes overload,\n      short-circuit, phase failure,\n      phase imbalance and equipment earth fault protection.\n      The front plug-in modular construction supports\n      installation and maintenance of compatible\n      motor starter assemblies.\n      \u003cstrong\u003eLUCA1XBL is a control unit only,\n      not a complete motor starter.\u003c\/strong\u003e\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FAF3;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e\n          for compatible modular motor starter assemblies\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e0.35–1.4A adjustable current range\u003c\/strong\u003e\n          for three-phase motor applications\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e24V DC control circuit\u003c\/strong\u003e\n          with a specified 20–27V DC operating range\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e\n          with manual reset\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eBasic motor protection\u003c\/strong\u003e\n          against overload and short circuit\n          in compatible starter assemblies\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003ePhase failure and imbalance protection\u003c\/strong\u003e\n          with equipment earth fault protection\n        \u003c\/li\u003e\n\n        \u003cli\u003e\n          \u003cstrong\u003eFront plug-in modular design\u003c\/strong\u003e\n          for compatible TeSys U power bases\n        \u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003c!-- Conditional module omitted.\n         Supplied photos show LUCAX6BL, not LUCA1XBL.\n         Insert the frozen single verification module\n         only after matching LUCA1XBL photos are confirmed. --\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#26853A;\"\u003e\n        In Stock\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLUCA1XBL\u003c\/strong\u003e\n        is reported in stock.\n        This TeSys U standard control unit\n        features a \u003cstrong\u003e0.35–1.4A adjustable current range\u003c\/strong\u003e,\n        \u003cstrong\u003e24V DC control voltage\u003c\/strong\u003e\n        and \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e.\n        Please verify the complete model,\n        motor rated current, control voltage\n        and compatible power base before ordering.\n        The listing covers the control unit only;\n        the motor starter power base is not included.\n        For quantity or project requirements,\n        contact our sourcing team.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric LUCA1XBL\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#26853A;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/collections\/schneider\" style=\"color:#26853A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LUCAX6BL","offer_id":52318416601391,"sku":"LUCAX6BL","price":89.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-LUCA1XBL-TeSys-U-0_35-1_4A-24V-DC-Class-10-Standard-Control-Unit.jpg?v=1792345537"},{"product_id":"schneider-luca1xbl-control-unit","title":"Schneider Electric LUCA1XBL TeSys U 0.35-1.4A 24V DC Class 10 Standard Control Unit","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric LUCA1XBL TeSys U Standard Control Unit\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      0.35–1.4A | 24V DC | Class 10 | 3-Phase Motor Protection | TeSys U\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FAF3;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#26853A;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Packaging Photo\n       |  Exact Model Verified on Packaging\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FAF3;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUCA1XBL\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys U \/ TeSys Ultra\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eStandard Control Unit\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Control \/ Motor Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSpecific Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBasic Protection for Motor Starters\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eLoad Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree-Phase Self-Cooled Motor\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Current Adjustment Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e0.35–1.4 A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage (Uc)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage Limits\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20–27 V DC in Operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Drop-Out Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e14.5 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eClass 10\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Compensation Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTripping Threshold\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e14.2 × Ir ±20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Circuit Trip Setting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e13 × Irmax in Compatible Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eManual Reset\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverload Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible TeSys U Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort-Circuit Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible TeSys U Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Failure Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Imbalance Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEarth Fault Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEquipment Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V AC, Main Circuit of Compatible Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUtilisation Categories\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC-41 \/ AC-43 \/ AC-44\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 400–440V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.25 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Power Bases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUB12 \/ LUB32 \/ LUB38\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Closing Current with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e130 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Sealed Current with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Closing Current with LUB32\/LUB38\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e220 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Sealed Current with LUB32\/LUB38\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e80 mA at 24V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Heat Dissipation with LUB12\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Heat Dissipation with LUB32\/LUB38\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Opening Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e35 ms with Listed Compatible Bases\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Closing Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e70 ms with Listed Compatible Bases\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V IEC \/ 600 V UL \u0026amp; CSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 kV\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePlug-in, Front Face\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWidth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHeight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e66 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDepth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.135 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatibility Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Panel \/ Wired Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Outside Connection Zone\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP40\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-40°C to +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Operating Altitude\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2,000 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandards\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEN\/IEC 60947-6-2; UL 60947-4-1; CSA C22.2 No. 60947-4-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eGTIN \/ EAN\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110363821\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LUCA1XBL\u003c\/strong\u003e\n      is a standard control unit from the\n      \u003cstrong\u003eTeSys U \/ TeSys Ultra\u003c\/strong\u003e\n      modular motor starter range.\n      Designed for three-phase motor control and protection,\n      it provides an adjustable\n      \u003cstrong\u003e0.35–1.4A motor current range\u003c\/strong\u003e,\n      a \u003cstrong\u003e24V DC control circuit\u003c\/strong\u003e\n      and \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e.\n      When installed in a compatible TeSys U starter assembly,\n      the control unit supports overload, short-circuit,\n      phase failure, phase imbalance and\n      equipment earth fault protection.\n      Its electronic current adjustment function\n      and front plug-in modular construction\n      support installation and maintenance.\n      \u003cstrong\u003eLUCA1XBL is a standard control unit only,\n      not a complete motor starter.\u003c\/strong\u003e\n      A compatible power base must be selected separately.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FAF3;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e\n          for compatible modular motor starter assemblies\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e0.35–1.4A adjustable motor current range\u003c\/strong\u003e\n          for three-phase motor protection\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e24V DC control circuit\u003c\/strong\u003e\n          with a manufacturer-specified\n          20–27V DC operating range\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e\n          with manual reset\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eBasic motor protection functions\u003c\/strong\u003e\n          including overload and short-circuit protection\n          with a compatible power base\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003ePhase failure and imbalance protection\u003c\/strong\u003e\n          with equipment earth fault protection\n        \u003c\/li\u003e\n\n        \u003cli\u003e\n          \u003cstrong\u003eFront plug-in modular design\u003c\/strong\u003e\n          for compatible TeSys U power bases\n        \u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E9DA;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Actual Schneider packaging photo\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Exact model \u003cstrong\u003eLUCA1XBL\u003c\/strong\u003e\n          visible on the packaging label\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          \u003cstrong\u003e0.35–1.4A\u003c\/strong\u003e current range\n          and \u003cstrong\u003e24V DC\u003c\/strong\u003e marking visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Schneider branding, manufacturer markings,\n          barcode and package quantity x1 visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model, current range,\n          control voltage and compatible\n          TeSys U power base before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#26853A;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLUCA1XBL\u003c\/strong\u003e\n        is currently reported in stock.\n        An actual Schneider packaging photograph\n        is available for model verification.\n        This \u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e\n        features a \u003cstrong\u003e0.35–1.4A adjustable motor current range\u003c\/strong\u003e,\n        \u003cstrong\u003e24V DC control voltage\u003c\/strong\u003e\n        and \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e.\n        The control unit is intended for use\n        with an approved TeSys U power base.\n        \u003cstrong\u003eThis listing is for the control unit only.\u003c\/strong\u003e\n        Please confirm the exact model,\n        motor rated current, control voltage,\n        compatible starter power base\n        and required quantity before purchasing.\n        Contact our team for international\n        shipping arrangements.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric LUCA1XBL\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#26853A;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/collections\/schneider\" style=\"color:#26853A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LUCA1XBL","offer_id":52318458151215,"sku":"LUCA1XBL","price":89.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-LUCA1XBL-TeSys-U-0_35-1_4A-24V-DC-Class-10-Standard-Control-Unit_69d1092a.jpg?v=1792345557"},{"product_id":"schneider-luca18bl-control-unit","title":"Schneider Electric LUCA18BL TeSys U 4.5-18A 24V DC Class 10 Standard Control Unit","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric LUCA18BL TeSys U Standard Motor Control Unit\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      4.5–18A | 24V DC | Class 10 | 3-Phase Motor Protection | TeSys U\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FAF3;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#26853A;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Exact Model on Packaging\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FAF3;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUCA18BL\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTeSys U \/ TeSys Ultra\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eStandard Control Unit\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Control \/ Motor Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSpecific Application\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBasic Motor Starter Protection: Overload and Short Circuit\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eLoad Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3-Phase Self-Cooled Motor\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Current Adjustment Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e4.5–18 A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage (Uc)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e24 V DC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Voltage Limits\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20–27 V DC in Operation\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Drop-Out Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e14.5 V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Overload Class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eClass 10\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eThermal Compensation Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTripping Threshold\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e14.2 × Ir ±20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eReset Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eManual Reset\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverload Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eShort Circuit Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eWith Compatible Power Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Failure Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhase Imbalance Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEarth Fault Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes, Equipment Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Voltage (Ue)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V AC, Main Circuit of Compatible Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUtilisation Categories\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC-41 \/ AC-43 \/ AC-44\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 400–440V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e7.5 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 500V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e9 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 690V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e15 kW at 50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Power Bases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eLUB32 \/ LUB38 \/ LUB320 \/ LUB380\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatible Reversing Devices\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLU2B32BL \/ LU2B38BL\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Closing Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e220 mA at 24V DC with LUB32\/LUB38\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTypical Sealed Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e80 mA at 24V DC with LUB32\/LUB38\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Heat Dissipation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3 W with LUB32\/LUB38\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Opening Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e35 ms with LUB32\/LUB38\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Closing Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e70 ms with LUB32\/LUB38\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e690 V IEC \/ 600 V UL \u0026amp; CSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Impulse Withstand Voltage (Uimp)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6 kV\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMounting Mode\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePlug-in, Front Face\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWidth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eHeight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e66 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDepth\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.135 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCompatibility Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eLUCA\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Panel \/ Wired Terminals\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFront Outside Connection Zone\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP40\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-25°C to +70°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-40°C to +85°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Operating Altitude\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2,000 m\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandards\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEN\/IEC 60947-6-2; UL 60947-4-1; CSA C22.2 No. 60947-4-1\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eGTIN \/ EAN\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3389110363852\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Package Quantity\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1 Piece\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric LUCA18BL\u003c\/strong\u003e\n      is a standard control unit from the\n      \u003cstrong\u003eTeSys U \/ TeSys Ultra\u003c\/strong\u003e\n      modular motor starter range.\n      It provides an adjustable\n      \u003cstrong\u003e4.5–18A motor current range\u003c\/strong\u003e,\n      a \u003cstrong\u003e24V DC control circuit\u003c\/strong\u003e\n      and \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e\n      for three-phase motor applications.\n      Its basic protection functions support\n      overload, short-circuit, phase failure,\n      phase imbalance and equipment earth fault\n      protection when installed in a compatible\n      TeSys U starter assembly.\n      The electronic control unit includes\n      a current adjustment dial and manual reset.\n      Its front plug-in construction supports\n      modular installation and servicing.\n      \u003cstrong\u003eLUCA18BL is a standard control unit only,\n      not a complete motor starter.\u003c\/strong\u003e\n      A compatible power base and any required\n      accessories must be selected separately.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FAF3;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e for compatible modular motor starter assemblies\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e4.5–18A adjustable motor current range\u003c\/strong\u003e for three-phase motor protection\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e24V DC control voltage\u003c\/strong\u003e with a 20–27V DC operating range\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e with manual reset\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBasic motor protection functions\u003c\/strong\u003e including overload, short circuit and phase failure\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003ePhase imbalance and equipment earth fault protection\u003c\/strong\u003e in a correctly configured starter assembly\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eFront plug-in modular design\u003c\/strong\u003e for compatible TeSys U power bases\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E9DA;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#26853A;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Schneider Electric branding and product body markings visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Schneider packaging shown with exact model LUCA18BL visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#26853A;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003eLUCA18BL\u003c\/strong\u003e,\n          24V DC control voltage, 4.5–18A current range\n          and compatible power base before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#26853A;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eLUCA18BL\u003c\/strong\u003e\n        is currently reported in stock.\n        Actual product and Schneider packaging\n        photos are available for buyer verification.\n        This \u003cstrong\u003eTeSys U standard control unit\u003c\/strong\u003e\n        provides an \u003cstrong\u003e4.5–18A adjustable motor current range\u003c\/strong\u003e,\n        \u003cstrong\u003e24V DC control voltage\u003c\/strong\u003e\n        and \u003cstrong\u003eClass 10 thermal overload protection\u003c\/strong\u003e.\n        Its basic protection functions support\n        three-phase motor applications\n        when used with a compatible power base.\n        \u003cstrong\u003eThis listing is for the control unit only.\u003c\/strong\u003e\n        Please confirm the exact model,\n        motor rated current, control voltage\n        and approved power base before purchasing.\n        Contact our team for international\n        shipping arrangements.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric LUCA18BL\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#26853A;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/es\/collections\/schneider\" style=\"color:#26853A;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"LUCA18BL","offer_id":52319675285807,"sku":"LUCA18BL","price":89.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-LUCA18BL-TeSys-U-4_5-18A-24V-DC-Class-10-Standard-Control-Unit.jpg?v=1792345627"}],"url":"https:\/\/szyingzhou.com\/es\/collections\/schneider-control-units.oembed","provider":"YingZhou Automatization","version":"1.0","type":"link"}