{"title":"Industrial Soft Starters for AC Motor Control","description":"\n\u003cdiv style=\"width:100%;margin:0;\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"\n    background:#005EB8;\n    border-radius:12px;\n    padding:24px 28px 22px;\n    color:#FFFFFF;\n  \"\u003e\n\n    \u003cdiv style=\"\n      margin:0 0 6px;\n      font-size:10.5px;\n      line-height:1.4;\n      font-weight:700;\n      letter-spacing:1.15px;\n      text-transform:uppercase;\n      color:#FFFFFF;\n    \"\u003e\n      INDUSTRIAL SOFT STARTERS\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"\n      margin:0 0 7px;\n      color:#FFFFFF;\n      font-size:25px;\n      line-height:1.3;\n      font-weight:700;\n    \"\u003e\n      Industrial Soft Starters for AC Motor Control Systems\n    \u003c\/h2\u003e\n\n    \u003cp style=\"\n      margin:0;\n      max-width:850px;\n      color:#FFFFFF;\n      font-size:14px;\n      line-height:1.6;\n    \"\u003e\n      Explore industrial soft starters designed for\n      controlled AC motor starting and stopping,\n      helping reduce starting current and mechanical\n      stress in industrial equipment. Find compact\n      motor soft starters, three-phase soft starters,\n      bypass-equipped solutions and related accessories\n      from leading manufacturers, with model identification\n      and quotation support from YINGZHOU.\n    \u003c\/p\u003e\n\n    \u003c!-- PRODUCT RANGE --\u003e\n    \u003cdiv style=\"\n      margin-top:16px;\n      padding-top:13px;\n      border-top:1px solid rgba(255,255,255,.35);\n    \"\u003e\n\n      \u003cdiv style=\"\n        margin-bottom:5px;\n        font-size:10px;\n        line-height:1.4;\n        font-weight:700;\n        letter-spacing:.9px;\n        text-transform:uppercase;\n        color:#FFFFFF;\n      \"\u003e\n        PRODUCT RANGE\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"\n        font-size:12.5px;\n        line-height:1.6;\n        font-weight:700;\n        color:#FFFFFF;\n      \"\u003e\n        Three-Phase Soft Starters\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Compact Soft Starters\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Built-In Bypass Soft Starters\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        External Bypass Soft Starter Systems\n        \u003cspan style=\"margin:0 9px;opacity:.75;\"\u003e•\u003c\/span\u003e\n        Soft Starter Accessories\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- PRODUCT FAMILIES --\u003e\n    \u003cdiv style=\"margin-top:11px;\"\u003e\n\n      \u003cdiv style=\"\n        margin-bottom:4px;\n        font-size:10px;\n        line-height:1.4;\n        font-weight:700;\n        letter-spacing:.9px;\n        text-transform:uppercase;\n        color:#FFFFFF;\n      \"\u003e\n        APPLICATIONS\n      \u003c\/div\u003e\n\n      \u003cdiv style=\"\n        font-size:12px;\n        line-height:1.6;\n        color:#FFFFFF;\n      \"\u003e\n        Industrial Motor Starting ·\n        Pump Control Systems ·\n        Conveyor Systems ·\n        Fan \u0026amp; Compressor Applications ·\n        Industrial Machinery Automation\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- BUYER ASSISTANCE --\u003e\n  \u003cdiv style=\"\n    display:flex;\n    flex-wrap:wrap;\n    align-items:center;\n    justify-content:space-between;\n    gap:6px 18px;\n    margin-top:8px;\n    padding:10px 15px;\n    background:#f7f9fb;\n    border:1px solid #e8edf1;\n    border-radius:7px;\n    font-size:12.5px;\n    line-height:1.55;\n    color:#555555;\n  \"\u003e\n\n    \u003cdiv\u003e\n      \u003cstrong style=\"color:#222222;\"\u003e\n        Need a specific soft starter?\n      \u003c\/strong\u003e\n      Send us the\n      \u003cstrong style=\"color:#222222;\"\u003e\n        model\/part number + quantity\n      \u003c\/strong\u003e.\n    \u003c\/div\u003e\n\n    \u003cdiv style=\"color:#555555;white-space:nowrap;\"\u003e\n      Availability\n      \u003cspan style=\"margin:0 6px;color:#b7bec4;\"\u003e·\u003c\/span\u003e\n      Lead Time\n      \u003cspan style=\"margin:0 6px;color:#b7bec4;\"\u003e·\u003c\/span\u003e\n      Quotation\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n","products":[{"product_id":"danfoss-136g7354-mcd-600-soft-starter-527a-mcd60527b","title":"Danfoss 136G7354 VLT MCD 600 527A 200-525V IP00 Built-in Bypass Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #E31B23;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#E31B23;padding:26px 30px;color:#FFFFFF;\"\u003e\n\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Danfoss 136G7354 VLT Soft Starter MCD 600\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      527A | 3-Phase 200-525V | IP00 | Built-in Bypass\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- LEAD-TIME STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF1F2;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n\n    \u003cstrong style=\"color:#C51620;\"\u003e\n      AVAILABLE TO ORDER - ESTIMATED DELIVERY 4-5 WEEKS\n    \u003c\/strong\u003e\n\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Model \u0026amp; Nameplate Visible\n    \u003c\/span\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#FFF1F2;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDanfoss\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOrdering Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e136G7354\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;overflow-wrap:anywhere;\"\u003e\u003cstrong\u003eMCD60527BT5S2X00CV2\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eComplete Type Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;overflow-wrap:anywhere;\"\u003eMCD6-0527B-T5-S2X-00-CV2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eVLT Soft Starter MCD 600\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eAC Motor Soft Starter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNominal Current Class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e527A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3 x 200-525V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSupply Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-53b Duty Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e550A : AC-53b 3-10:590 (40°C reference conditions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNominal AC-53b Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e527A : AC-53b 3.5-15:585 (40°C reference conditions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power Reference\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e300kW \/ 410HP at 400VAC - Nameplate, duty-dependent\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBypass Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBuilt-in Bypass Contactor\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEnclosure Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eIP00 \/ UL Open Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFrame Size\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eS2 - Frame Size 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCV2 - 110-120V AC or 220-240V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Overload Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eClass 10A - Nameplate\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturing Origin\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNew Zealand - Nameplate\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #E31B23;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eDanfoss 136G7354\u003c\/strong\u003e\n      is a \u003cstrong\u003eVLT Soft Starter MCD 600\u003c\/strong\u003e\n      designed for controlled starting and\n      stopping of industrial AC motors.\n\n      The exact configuration\n      \u003cstrong\u003eMCD60527BT5S2X00CV2\u003c\/strong\u003e,\n      also formatted as\n      \u003cstrong\u003eMCD6-0527B-T5-S2X-00-CV2\u003c\/strong\u003e,\n      identifies a \u003cstrong\u003e527A current-class\u003c\/strong\u003e\n      three-phase soft starter with a\n      \u003cstrong\u003e200-525V AC\u003c\/strong\u003e mains supply.\n\n      This MCD 600 configuration features\n      an \u003cstrong\u003eintegrated bypass contactor\u003c\/strong\u003e,\n      helping reduce losses during\n      normal running after the\n      starting sequence.\n\n      The unit is configured with an\n      \u003cstrong\u003eIP00 open-frame enclosure\u003c\/strong\u003e\n      in \u003cstrong\u003eS2 frame size\u003c\/strong\u003e.\n      It requires installation in an\n      appropriate electrical enclosure\n      with suitable protection.\n\n      The manufacturer's\n      \u003cstrong\u003eCV2 control voltage\u003c\/strong\u003e\n      configuration supports\n      \u003cstrong\u003e110-120V AC or 220-240V AC\u003c\/strong\u003e.\n\n      The product nameplate identifies\n      a \u003cstrong\u003e550A current rating\u003c\/strong\u003e\n      under the specified\n      \u003cstrong\u003eAC-53b:3-10:590\u003c\/strong\u003e\n      duty condition and a\n      \u003cstrong\u003e300kW (410HP)\u003c\/strong\u003e\n      motor power reference at 400VAC.\n\n      The manufacturer's current-rating\n      table also lists\n      \u003cstrong\u003e527A\u003c\/strong\u003e under the\n      \u003cstrong\u003eAC-53b:3.5-15:585\u003c\/strong\u003e\n      duty condition.\n\n      Actual current capability and\n      motor selection depend on\n      starting duty, installation,\n      ambient temperature and\n      motor full-load current.\n\n      The MCD 600 series provides\n      adaptive starting and stopping\n      functions, motor protection\n      and configuration options\n      for industrial motor-control systems.\n\n      The actual product photographs\n      show the Danfoss identification\n      label and packaging with\n      ordering code\n      \u003cstrong\u003e136G7354\u003c\/strong\u003e\n      and the exact type code.\n\n      Before ordering, please confirm\n      the full model configuration,\n      operating voltage, control voltage,\n      motor load and application duty.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF1F2;border-left:8px solid #E31B23;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C51620;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eDanfoss VLT Soft Starter MCD 600\u003c\/strong\u003e\n          industrial motor starting solution\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e527A nominal current class\u003c\/strong\u003e\n          with duty-dependent AC-53b ratings\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eThree-phase 200-525V AC supply\u003c\/strong\u003e\n          for the T5 mains voltage configuration\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eBuilt-in bypass contactor\u003c\/strong\u003e\n          for efficient running after motor startup\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eIP00 open-frame construction\u003c\/strong\u003e\n          with S2 frame size\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eCV2 control voltage configuration\u003c\/strong\u003e\n          supporting 110-120V AC or 220-240V AC\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eExact manufacturer identification\u003c\/strong\u003e\n          with ordering code 136G7354\n          and complete model number\n        \u003c\/li\u003e\n\n        \u003cli\u003e\n          \u003cstrong\u003eEstimated delivery 4-5 weeks\u003c\/strong\u003e\n          with actual product and packaging photos\n        \u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D7D9;border-radius:8px;background:#FFFAFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C51620;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Actual Danfoss MCD 600 soft starter photographs\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Manufacturer ordering code\n          \u003cstrong\u003e136G7354\u003c\/strong\u003e\n          visible on the identification label\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Exact type code\n          \u003cstrong\u003eMCD6-0527B-T5-S2X-00-CV2\u003c\/strong\u003e\n          visible for model verification\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Nameplate shows the 200-525V AC\n          rating, IP00 enclosure and\n          AC-53b duty information\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Actual product housing and\n          Danfoss packaging label photographed\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Confirm exact model, motor duty\n          and required accessories before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #E31B23;border-left:8px solid #E31B23;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C51620;\"\u003e\n        Available to Order - Estimated Delivery 4-5 Weeks\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        The \u003cstrong\u003eDanfoss 136G7354\u003c\/strong\u003e\n        VLT Soft Starter MCD 600 is\n        \u003cstrong\u003eavailable to order\u003c\/strong\u003e\n        with an estimated delivery time\n        of \u003cstrong\u003e4-5 weeks\u003c\/strong\u003e.\n\n        This listing refers specifically\n        to the exact configuration\n        \u003cstrong\u003eMCD60527BT5S2X00CV2\u003c\/strong\u003e\n        with a 527A current class,\n        three-phase 200-525V AC supply,\n        integrated bypass contactor,\n        IP00 enclosure and CV2 control voltage.\n\n        YINGZHOU supports individual\n        replacement-unit orders,\n        industrial maintenance sourcing,\n        project procurement and\n        consolidated multi-brand purchases.\n\n        Please confirm the exact ordering\n        code, required quantity,\n        motor starting duty,\n        voltage requirements and\n        any required accessories\n        before placing your order.\n\n        Contact our sales team for current\n        procurement arrangements,\n        lead-time confirmation and\n        international shipping support.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#E31B23;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        AVAILABLE TO ORDER - ESTIMATED DELIVERY 4-5 WEEKS\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Danfoss 136G7354 | MCD 600 Soft Starter\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Request a quotation or confirm your industrial purchasing requirements.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C51620;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- DANFOSS BRAND COLLECTION LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Danfoss drives, soft starters and industrial automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/danfoss\" style=\"color:#C51620;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Danfoss Drives \u0026amp; Industrial Automation Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Danfoss","offers":[{"title":"MCD60527BT5S2X00CV2","offer_id":50771444334895,"sku":"MCD60527BT5S2X00CV2","price":6085.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Danfoss-136G7354-VLT-MCD-600-527A-200-525V-IP00-Built-in-Bypass-Soft-Starter.jpg?v=1792342898"},{"product_id":"danfoss-136g8779-mcd-600-soft-starter-194a-mcd60194b","title":"Danfoss 136G8779 VLT MCD 600 194A 200-525V IP00 Built-in Bypass Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #E31B23;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#E31B23;padding:26px 30px;color:#FFFFFF;\"\u003e\n\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Danfoss 136G8779 VLT Soft Starter MCD 600\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      194A | 3-Phase 200-525V | IP00 | Built-in Bypass\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- LEAD-TIME STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF1F2;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n\n    \u003cstrong style=\"color:#C51620;\"\u003e\n      AVAILABLE TO ORDER - ESTIMATED DELIVERY 3-4 WEEKS\n    \u003c\/strong\u003e\n\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Model \u0026amp; Nameplate Visible\n    \u003c\/span\u003e\n\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#FFF1F2;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDanfoss\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOrdering Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e136G8779\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;overflow-wrap:anywhere;\"\u003e\u003cstrong\u003eMCD60194BT5S2X00CV2\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eComplete Type Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;overflow-wrap:anywhere;\"\u003eMCD6-0194B-T5-S2X-00-CV2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eVLT Soft Starter MCD 600\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eAC Motor Soft Starter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNominal Current Class\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e194A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3 x 200-525V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSupply Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAC-53b Duty Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e229A : AC-53b 3-10:590 (40°C reference conditions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNominal AC-53b Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e194A : AC-53b 3.5-15:585 (40°C reference conditions)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power Reference\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e110kW \/ 150HP at 400VAC - Nameplate, duty-dependent\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBypass Configuration\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBuilt-in Bypass Contactor\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEnclosure Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eIP00 \/ UL Open Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFrame Size\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eS2 - Frame Size 2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCV2 - 110-120V AC or 220-240V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Overload Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eClass 10A - Nameplate\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturing Origin\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNew Zealand - Nameplate\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #E31B23;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eDanfoss 136G8779\u003c\/strong\u003e\n      is a \u003cstrong\u003eVLT Soft Starter MCD 600\u003c\/strong\u003e\n      designed for controlled starting and\n      stopping of industrial AC motors.\n\n      The exact configuration\n      \u003cstrong\u003eMCD60194BT5S2X00CV2\u003c\/strong\u003e,\n      also formatted as\n      \u003cstrong\u003eMCD6-0194B-T5-S2X-00-CV2\u003c\/strong\u003e,\n      identifies a \u003cstrong\u003e194A current-class\u003c\/strong\u003e\n      three-phase soft starter with a\n      \u003cstrong\u003e200-525V AC\u003c\/strong\u003e mains supply.\n\n      This MCD 600 configuration features\n      an \u003cstrong\u003eintegrated bypass contactor\u003c\/strong\u003e,\n      helping reduce losses during\n      normal running after the\n      starting sequence.\n\n      The unit is configured with an\n      \u003cstrong\u003eIP00 open-frame enclosure\u003c\/strong\u003e\n      in \u003cstrong\u003eS2 frame size\u003c\/strong\u003e.\n      It requires installation in an\n      appropriate electrical enclosure\n      with suitable protection.\n\n      The manufacturer's\n      \u003cstrong\u003eCV2 control voltage\u003c\/strong\u003e\n      configuration supports\n      \u003cstrong\u003e110-120V AC or 220-240V AC\u003c\/strong\u003e.\n\n      The product nameplate identifies\n      a \u003cstrong\u003e229A current rating\u003c\/strong\u003e\n      under the specified\n      \u003cstrong\u003eAC-53b:3-10:590\u003c\/strong\u003e\n      duty condition and a\n      \u003cstrong\u003e110kW (150HP)\u003c\/strong\u003e\n      motor power reference at 400VAC.\n\n      Actual current capability and\n      motor selection depend on\n      starting duty, installation,\n      ambient temperature and\n      motor full-load current.\n\n      The MCD 600 series provides\n      adaptive starting and stopping\n      functions, motor protection\n      and configuration options\n      for industrial motor-control systems.\n\n      The actual product photographs\n      show the Danfoss identification\n      label and packaging with\n      ordering code\n      \u003cstrong\u003e136G8779\u003c\/strong\u003e\n      and the exact type code.\n\n      Before ordering, please confirm\n      the full model configuration,\n      operating voltage, control voltage,\n      motor load and application duty.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF1F2;border-left:8px solid #E31B23;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C51620;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eDanfoss VLT Soft Starter MCD 600\u003c\/strong\u003e\n          industrial motor starting solution\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003e194A nominal current class\u003c\/strong\u003e\n          with duty-dependent AC-53b ratings\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eThree-phase 200-525V AC supply\u003c\/strong\u003e\n          for the T5 mains voltage configuration\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eBuilt-in bypass contactor\u003c\/strong\u003e\n          for efficient running after motor startup\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eIP00 open-frame construction\u003c\/strong\u003e\n          with S2 frame size\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eCV2 control voltage configuration\u003c\/strong\u003e\n          supporting 110-120V AC or 220-240V AC\n        \u003c\/li\u003e\n\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n          \u003cstrong\u003eExact manufacturer identification\u003c\/strong\u003e\n          with ordering code 136G8779\n          and complete model number\n        \u003c\/li\u003e\n\n        \u003cli\u003e\n          \u003cstrong\u003eEstimated delivery 3-4 weeks\u003c\/strong\u003e\n          with actual product and packaging photos\n        \u003c\/li\u003e\n\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D7D9;border-radius:8px;background:#FFFAFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C51620;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Actual Danfoss MCD 600 soft starter photographs\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Manufacturer ordering code\n          \u003cstrong\u003e136G8779\u003c\/strong\u003e\n          visible on the identification label\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Exact type code\n          \u003cstrong\u003eMCD6-0194B-T5-S2X-00-CV2\u003c\/strong\u003e\n          visible for model verification\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Nameplate shows the 200-525V AC\n          rating, IP00 enclosure and\n          AC-53b duty information\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Actual product housing and\n          Danfoss packaging label photographed\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e\n          Confirm exact model, motor duty\n          and required accessories before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #E31B23;border-left:8px solid #E31B23;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C51620;\"\u003e\n        Available to Order - Estimated Delivery 3-4 Weeks\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        The \u003cstrong\u003eDanfoss 136G8779\u003c\/strong\u003e\n        VLT Soft Starter MCD 600 is\n        \u003cstrong\u003eavailable to order\u003c\/strong\u003e\n        with an estimated delivery time\n        of \u003cstrong\u003e3-4 weeks\u003c\/strong\u003e.\n\n        This listing refers specifically\n        to the exact configuration\n        \u003cstrong\u003eMCD60194BT5S2X00CV2\u003c\/strong\u003e\n        with a 194A current class,\n        three-phase 200-525V AC supply,\n        integrated bypass contactor,\n        IP00 enclosure and CV2 control voltage.\n\n        YINGZHOU supports individual\n        replacement-unit orders,\n        industrial maintenance sourcing,\n        project procurement and\n        consolidated multi-brand purchases.\n\n        Please confirm the exact ordering\n        code, required quantity,\n        motor starting duty,\n        voltage requirements and\n        any required accessories\n        before placing your order.\n\n        Contact our sales team for current\n        procurement arrangements,\n        lead-time confirmation and\n        international shipping support.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#E31B23;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        AVAILABLE TO ORDER - ESTIMATED DELIVERY 3-4 WEEKS\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Danfoss 136G8779 | MCD 600 Soft Starter\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Request a quotation or confirm your industrial purchasing requirements.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C51620;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- DANFOSS BRAND COLLECTION LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Danfoss drives, soft starters and industrial automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/danfoss\" style=\"color:#C51620;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Danfoss Drives \u0026amp; Industrial Automation Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Danfoss","offers":[{"title":"MCD60194BT5S2X00CV2","offer_id":50771452494127,"sku":"MCD60194BT5S2X00CV2","price":2499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Danfoss-136G8779-VLT-MCD-600-194A-200-525V-IP00-Built-in-Bypass-Soft-Starter.jpg?v=1792342905"},{"product_id":"danfoss-132h2229-mcd-600-soft-starter-448a-mcd60448c","title":"Danfoss 132H2229 MCD 600 448A Soft Starter 200–525 VAC IP00","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #E31B23;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#E31B23;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003eYingZhou Industrial Automation | Product Information\u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003eDanfoss 132H2229 VLT® Soft Starter MCD 600 448A\u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003eMCD6-0448C-T5-S2X-00-CV2 | 3-Phase 200–525 VAC | IP00 Open Frame\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK \/ LEAD-TIME STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#E31B23;\"\u003e✓ AVAILABLE TO ORDER — ESTIMATED DELIVERY 3–4 WEEKS\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product \u0026amp; Packaging Photos  |  Exact Part Number 132H2229\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e132H2229\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Type Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eMCD6-0448C-T5-S2X-00-CV2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eVLT® Soft Starter MCD 600\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDigital Soft Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eModel Current Class\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e448 A model designation\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3-phase, 200–525 VAC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSupply Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNameplate Current Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e474 A at AC-53a: 3.0-10:50-6\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power on Nameplate\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e250 kW (350 HP) at 400 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP00 (open frame)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFrame Size\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eS2X \/ Frame Size 2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Voltage Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCV2 — 110–120 VAC or 220–240 VAC, per Danfoss type-code guide\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e16.0 kg (nameplate \/ official guide)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture on Label\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eNew Zealand\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #E31B23;padding-bottom:7px;\"\u003eProduct Overview\u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003eThe \u003cstrong\u003eDanfoss 132H2229\u003c\/strong\u003e is a \u003cstrong\u003eVLT® Soft Starter MCD 600\u003c\/strong\u003e with the exact type code \u003cstrong\u003eMCD6-0448C-T5-S2X-00-CV2\u003c\/strong\u003e. The nameplate identifies a 3-phase \u003cstrong\u003e200–525 VAC, 50\/60 Hz\u003c\/strong\u003e supply and an AC-53a current rating of \u003cstrong\u003e474 A at 3.0-10:50-6\u003c\/strong\u003e. The product code identifies the 448 A model class; the applicable current rating depends on the AC-53 duty conditions and installation method. The nameplate also states \u003cstrong\u003e250 kW (350 HP) at 400 VAC\u003c\/strong\u003e, an \u003cstrong\u003eIP00 open-frame\u003c\/strong\u003e enclosure and a weight of \u003cstrong\u003e16.0 kg\u003c\/strong\u003e. Select the soft starter against the motor full-load current and required starting duty using the official Danfoss selection guidance.\u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #E31B23;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#E31B23;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eVLT® Soft Starter MCD 600\u003c\/strong\u003e — Digital soft-start platform for fixed-speed motor applications.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e132H2229 Exact Part Number\u003c\/strong\u003e — Matches the part number shown on the supplied product and packaging labels.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e3-Phase 200–525 VAC Supply\u003c\/strong\u003e — T5 voltage code, as shown on the product label and Danfoss type-code guide.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e474 A at AC-53a: 3.0-10:50-6\u003c\/strong\u003e — Current rating and duty code shown on the nameplate.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e250 kW (350 HP) at 400 VAC\u003c\/strong\u003e — Motor power rating printed on the product label.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIP00 Open-Frame Design\u003c\/strong\u003e — Protection code confirmed by the type-code guide.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eMotor and System Protection Functions\u003c\/strong\u003e — The MCD 600 platform includes configurable motor and system protection features documented by Danfoss.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#E31B23;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e Actual product photo provided — rear \/ rating label visible\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e Actual packaging photo provided — part number 132H2229 and type code visible\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e Product type, voltage code and IP00 marking can be checked against the supplied labels\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#E31B23;\"\u003e✓\u003c\/strong\u003e Confirm motor full-load current, starting duty and installation requirements before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #E31B23;border-left:8px solid #E31B23;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#E31B23;\"\u003eAvailable to Order — Estimated Delivery 3–4 Weeks\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003eDanfoss \u003cstrong\u003e132H2229\u003c\/strong\u003e is available to order with an \u003cstrong\u003eestimated delivery time of 3–4 weeks\u003c\/strong\u003e, based on the supplied commercial information. Please reconfirm the delivery schedule when placing the order.\u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#E31B23;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eESTIMATED DELIVERY 3–4 WEEKS\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eDanfoss 132H2229 MCD 600\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003eContact us for quantity and project pricing. Confirm the exact configuration and motor-starting duty before ordering.\u003c\/p\u003e\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#E31B23;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Project Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- DANFOSS BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Danfoss industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/collections\/danfoss\" style=\"color:#E31B23;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Danfoss Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Danfoss","offers":[{"title":"MCD60448CT5S2X00CV2","offer_id":51106186789167,"sku":"MCD60448CT5S2X00CV2","price":3591.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Danfoss-132H2229-MCD-600-448A-Soft-Starter-200-525-VAC-IP00.jpg?v=1792468998"},{"product_id":"abb-psrc85-600-70-soft-starter-85a-45kw","title":"ABB PSRC85-600-70 PSRC Series 85A 45kW 208-600V AC Softstarter with Fixed Settings for Scroll Compressors","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n\u003c!-- HERO --\u003e\n\u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n\u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003eYingZhou Industrial Automation | Product Information\u003c\/div\u003e\n\u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003eABB PSRC85-600-70 Softstarter\u003c\/h2\u003e\n\u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e85A | 45kW @ 400V | 208–600V AC | Built-in Bypass | IP10\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- STOCK STATUS --\u003e\n\u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓ IN STOCK \u0026amp; READY TO ORDER\u003c\/strong\u003e\n\u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctr style=\"background:#FFF4F4;\"\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003ePSRC85-600-70\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eABB Order Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1SFA896214R7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSRC Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Softstarter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e85A (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Full-Load Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 400V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e45kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperational Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e208–600V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e100–240V AC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Start \/ Soft Stop\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTwo-phase voltage ramp control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Parameters\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eFixed settings for scroll compressors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBypass\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSignal Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRUN \/ TOR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e220 × 70 × 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"padding:30px;\"\u003e\n\n\u003c!-- PRODUCT OVERVIEW --\u003e\n\u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003eThe \u003cstrong\u003eABB PSRC85-600-70\u003c\/strong\u003e is a compact industrial motor softstarter from the \u003cstrong\u003eABB PSRC Series\u003c\/strong\u003e, specifically designed for scroll compressor applications. It provides a rated operational current of \u003cstrong\u003e85A (IEC)\u003c\/strong\u003e and supports \u003cstrong\u003e45kW three-phase motors at 400V\u003c\/strong\u003e under ABB's specified normal-start conditions. With a rated operational voltage of \u003cstrong\u003e208–600V AC\u003c\/strong\u003e and a \u003cstrong\u003e100–240V AC, 50\/60Hz\u003c\/strong\u003e control supply, the unit provides fixed-setting soft starting and stopping optimized for scroll compressors. Its integrated bypass reduces losses during normal motor operation. Manufacturer order code: \u003cstrong\u003e1SFA896214R7000\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003c!-- KEY PRODUCT FEATURES --\u003e\n\u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n\u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eABB PSRC Series\u003c\/strong\u003e — Compact softstarter for scroll compressor motor applications.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e85A Rated Current\u003c\/strong\u003e — IEC in-line operational current rating.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e45kW at 400V\u003c\/strong\u003e — Rated motor power under normal-start conditions.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–600V AC\u003c\/strong\u003e — Rated main operational voltage range.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e100–240V Control Supply\u003c\/strong\u003e — 50\/60Hz AC control voltage.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in Bypass\u003c\/strong\u003e — Reduces energy losses during normal running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed Start and Stop Settings\u003c\/strong\u003e — Factory-optimized configuration with no field parameter adjustment required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n\u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n\u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n\u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Actual product photographs provided\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Product nameplate visibly shows PSRC85-600-70\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e ABB order code 1SFA896214R7000 visible on product and packaging\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Actual packaging label photographed\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Verify exact model, electrical ratings and compressor starting conditions before ordering\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- AVAILABILITY --\u003e\n\u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003eIn Stock \u0026amp; Ready to Order\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003eABB \u003cstrong\u003ePSRC85-600-70\u003c\/strong\u003e is currently listed as in stock at YingZhou. Actual product and packaging photos support model identification before purchase. Please confirm motor rated current, operating voltage, compressor starting requirements and required external protection before installation.\u003c\/p\u003e\n\u003cp style=\"font-size:13px;color:#555;margin:12px 0 0;\"\u003e\u003cstrong\u003eInstallation Note:\u003c\/strong\u003e Select suitable upstream short-circuit protection and motor overload protection according to ABB's official installation and coordination instructions. The product packaging also contains a warning regarding upstream fuse protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- CTA --\u003e\n\u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003eIN STOCK\u003c\/div\u003e\n\u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003eABB PSRC85-600-70 | 85A Softstarter\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e45kW at 400V | Fixed Settings for Scroll Compressors | Actual Product Photos. Order online or contact us for project and quantity pricing.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Project Pricing\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ABB BRAND COLLECTION INTERNAL LINK --\u003e\n\u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other ABB industrial automation products?\u003c\/p\u003e\n\u003ca href=\"\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore ABB Industrial Automation Products\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"PSRC85-600-70","offer_id":51207857930543,"sku":"PSRC85-600-70","price":542.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-PSRC85-600-70-PSRC-Series-85A-45kW-208-600V-AC-Softstarter-with-Fixed-Settings-for-Scroll-Compressors.jpg?v=1792343569"},{"product_id":"allen-bradley-150-f108nbr-smc-flex-soft-starter","title":"Allen-Bradley 150-F108NBR SMC Flex 108A 75HP Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #CD173F;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#CD173F;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Allen-Bradley 150-F108NBR SMC Flex Soft Starter\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      108A | 200–480V AC | 3-Phase | 75HP @ 460V | 24V AC\/DC Control\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#CD173F;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model \u0026amp; Series Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e150-F108NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSMC Flex \/ Bulletin 150\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSolid-State Soft Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Control Function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree-Phase AC Motor Soft Starting \/ Stopping\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3-Phase Only\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Line Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e200–480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e24V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Line Controller Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e108A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 200V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30HP (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40HP (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 460V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e75HP (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInside-Delta Controller Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e234A (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInside-Delta Motor Power @ 200V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60HP (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInside-Delta Motor Power @ 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60HP (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInside-Delta Motor Power @ 460V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e125HP (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIEC Rated Operational Voltage Ue\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e200–400V AC (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInternal Bypass\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Overload Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOverload Trip Classes\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 \/ 15 \/ 20 \/ 30\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTrip Current Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e117% of Motor FLC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStatus Indications\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eStopped \/ Starting \/ Stopping \/ At Speed \/ Alarm \/ Fault\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAuxiliary Contacts\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eProgrammable NO\/NC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAuxiliary Contact Thermal Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5A AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAuxiliary Contact Make Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3600VA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAuxiliary Contact Break Rating\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e360VA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOpen Type\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Poles\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e443.7 x 196.4 x 212.2mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eApproximate Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e15kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-5°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5–95%, Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eUp to 2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Terminal Wire Size\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.75–2.5mm² \/ 18–14 AWG (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Terminal Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.6 N.m (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Terminal Lug\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e199-LF1 (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Terminal Wire Size\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e16–120mm² \/ 6–250 AWG (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Wire Lug Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e31 N.m (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eLug-to-Terminal Torque\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e17 N.m (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eWiring Material\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e75°C Copper Wire Only (Nameplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhotographed Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSeries B\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCarton Firmware Marking\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6.008; Unit Firmware Not Independently Read\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhotographed Serial Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e318752583\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNameplate Manufacturing Marking\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2408\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCarton Date\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e2024\/02\/22\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePhotographed Country Marking\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMexico\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Lifecycle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #CD173F;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eAllen-Bradley 150-F108NBR\u003c\/strong\u003e is an \u003cstrong\u003eSMC Flex solid-state soft starter\u003c\/strong\u003e manufactured by Rockwell Automation for three-phase industrial AC motor starting and stopping applications. It is part of the Bulletin 150 Smart Motor Controller family and provides a maximum \u003cstrong\u003e108A line-connected controller rating\u003c\/strong\u003e.\n      The manufacturer specifies a \u003cstrong\u003e200–480V AC three-phase power circuit\u003c\/strong\u003e operating at \u003cstrong\u003e50\/60Hz\u003c\/strong\u003e and a separate \u003cstrong\u003e24V AC\/DC control supply\u003c\/strong\u003e. The actual unit nameplate lists motor ratings of \u003cstrong\u003e30HP at 200V\u003c\/strong\u003e, \u003cstrong\u003e40HP at 230V\u003c\/strong\u003e, and \u003cstrong\u003e75HP at 460V\u003c\/strong\u003e for line-connected configurations.\n      The photographed nameplate additionally identifies an \u003cstrong\u003einside-delta controller current rating of 234A\u003c\/strong\u003e, with specific motor power ratings for this alternative wiring configuration. Line-connected and inside-delta ratings must not be treated as interchangeable. Actual motor sizing and connection must follow Rockwell Automation installation and application requirements.\n      The \u003cstrong\u003eSMC Flex 150-F108NBR\u003c\/strong\u003e features an \u003cstrong\u003eintegrated internal bypass\u003c\/strong\u003e, which supports efficient steady-state motor operation after the controlled starting sequence. The unit incorporates motor overload protection, configurable trip classes, programmable auxiliary contacts and controller status monitoring.\n      Rockwell Automation specifies a range of motor-control and protective functions for the SMC Flex family. Optional braking and special control packages should not be assumed to be installed in this exact catalog number without additional evidence.\n      The controller is manufactured in an \u003cstrong\u003eopen-type enclosure\u003c\/strong\u003e designed for installation inside an appropriately rated industrial control panel. Manufacturer dimensions are approximately \u003cstrong\u003e443.7 x 196.4 x 212.2mm\u003c\/strong\u003e, and the product weight is approximately \u003cstrong\u003e15kg\u003c\/strong\u003e.\n      Rockwell Automation currently lists catalog number \u003cstrong\u003e150-F108NBR\u003c\/strong\u003e as \u003cstrong\u003eActive\u003c\/strong\u003e.\n      The supplied actual photographs show a carton label and a physical controller nameplate, both marked \u003cstrong\u003e150-F108NBR, Series B\u003c\/strong\u003e, with matching serial number \u003cstrong\u003e318752583\u003c\/strong\u003e. The packaging carries firmware marking \u003cstrong\u003e6.008\u003c\/strong\u003e and date \u003cstrong\u003e2024\/02\/22\u003c\/strong\u003e, while the unit nameplate carries manufacturing marking \u003cstrong\u003e2408\u003c\/strong\u003e. Both labels identify \u003cstrong\u003ePRODUCT OF MEXICO\u003c\/strong\u003e.\n      The actual control firmware has not been independently read from the controller, and the unit has not been verified by a documented functional test or manufacturer authentication service. Please confirm the exact electrical configuration, compatible motor rating, operating condition and required accessories before ordering.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #CD173F;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#CD173F;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSMC Flex Soft Starter\u003c\/strong\u003e — Allen-Bradley Bulletin 150 solid-state controller for three-phase industrial AC motors.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e108A Line Controller Rating\u003c\/strong\u003e — Manufacturer-confirmed line-connected controller current rating.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e200–480V AC Main Circuit\u003c\/strong\u003e — Three-phase power circuit with a separate 24V AC\/DC control supply.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e75HP at 460V\u003c\/strong\u003e — Nameplate motor power rating for the specified line-connected voltage class.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIntegrated Internal Bypass\u003c\/strong\u003e — Built-in bypass design for steady-state motor operation after starting.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIntegrated Motor Overload Protection\u003c\/strong\u003e — Includes selectable trip classes and motor protection functionality.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eController Status Monitoring\u003c\/strong\u003e — Supports motor starting, stopping, at-speed, alarm and fault status indications.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#CD173F;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual product nameplate and carton label photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton catalog number: \u003cstrong\u003e150-F108NBR\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Controller nameplate catalog number: \u003cstrong\u003e150-F108NBR\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Exact catalog number match between carton and physical unit: \u003cstrong\u003ePASS\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Both labels identify \u003cstrong\u003eSeries B\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Both labels identify serial number \u003cstrong\u003e318752583\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton firmware marking: \u003cstrong\u003e6.008\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical controller firmware has not been independently read\u003c\/div\u003e\n        \u003cdiv\u003e✓ Carton date: \u003cstrong\u003e2024\/02\/22\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Unit nameplate manufacturing marking: \u003cstrong\u003e2408\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Both labels identify \u003cstrong\u003ePRODUCT OF MEXICO\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Nameplate identifies \u003cstrong\u003e200–480V AC, 3-phase, 50\/60Hz\u003c\/strong\u003e main supply\u003c\/div\u003e\n        \u003cdiv\u003e✓ Nameplate identifies \u003cstrong\u003e24V AC\/24V DC\u003c\/strong\u003e control supply\u003c\/div\u003e\n        \u003cdiv\u003e✓ Nameplate identifies \u003cstrong\u003e108A line controller current\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Nameplate identifies \u003cstrong\u003e234A delta controller current\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Nameplate identifies \u003cstrong\u003e75HP at 460V\u003c\/strong\u003e for line-connected operation\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rockwell Automation confirms integrated bypass and motor overload protection\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer currently lists catalog number \u003cstrong\u003e150-F108NBR\u003c\/strong\u003e as Active\u003c\/div\u003e\n        \u003cdiv\u003e✓ Functional testing and operational performance have not been independently verified\u003c\/div\u003e\n        \u003cdiv\u003e✓ Manufacturer authenticity and internal hardware condition have not been independently verified\u003c\/div\u003e\n        \u003cdiv\u003e✓ Confirm motor wiring configuration, control supply, accessories and dispatch requirements before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #CD173F;border-left:8px solid #CD173F;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#CD173F;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Allen-Bradley \u003cstrong\u003e150-F108NBR\u003c\/strong\u003e is marked \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory information.\n        This SMC Flex soft starter is rated for a \u003cstrong\u003e200–480V AC three-phase main circuit\u003c\/strong\u003e, \u003cstrong\u003e108A line controller current\u003c\/strong\u003e, and \u003cstrong\u003e24V AC\/DC control power\u003c\/strong\u003e, with \u003cstrong\u003e75HP motor rating at 460V\u003c\/strong\u003e under the manufacturer's specified line-connected conditions.\n        The controller includes an integrated internal bypass and motor overload protection. Its open-type construction is intended for installation inside a suitable industrial enclosure.\n        The actual carton and controller photographs show matching \u003cstrong\u003e150-F108NBR\u003c\/strong\u003e catalog numbers, \u003cstrong\u003eSeries B\u003c\/strong\u003e and serial number \u003cstrong\u003e318752583\u003c\/strong\u003e.\n        Functional testing, the internal hardware condition and actual unit firmware have not been independently verified.\n        Please confirm the exact electrical requirements, motor connection, accessories, stock allocation and shipping arrangements before completing an order.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#CD173F;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eAllen-Bradley 150-F108NBR\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, multiple units and project sourcing. Please confirm the 200–480V AC three-phase input, 108A line controller rating, 24V AC\/DC control supply, motor connection and installation requirements before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#CD173F;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ALLEN-BRADLEY BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Allen-Bradley industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/collections\/allen-bradley\" style=\"color:#CD173F;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Allen-Bradley Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Allen-Bradley","offers":[{"title":"150-F108NBR","offer_id":51269700813103,"sku":"150-F108NBR","price":2499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Allen-Bradley-150-F108NBR-SMC-Flex-108A-75HP-Soft-Starter.jpg?v=1793000081"},{"product_id":"abb-psr105-600-70-soft-starter-105a-55kw","title":"ABB PSR105-600-70 PSR Series 105A 55kW 208-600V AC Compact Softstarter with Built-in Bypass","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n\u003c!-- HERO --\u003e\n\u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n\u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003eYingZhou Industrial Automation | Product Information\u003c\/div\u003e\n\u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003eABB PSR105-600-70 Softstarter\u003c\/h2\u003e\n\u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e105A | 55kW @ 400V | 208–600V AC | Built-in Bypass | IP10\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- STOCK STATUS --\u003e\n\u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓ IN STOCK \u0026amp; READY TO ORDER\u003c\/strong\u003e\n\u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n\u003c\/div\u003e\n\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003ctr style=\"background:#FFF4F4;\"\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003ePSR105-600-70\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eABB Order Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1SFA896115R7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR Compact Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eMotor Softstarter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e105A (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Full-Load Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e104A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 400V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e55kW\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 230V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 500V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e55kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperational Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e208–600V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e100–240V AC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Start \/ Soft Stop\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTwo-phase voltage ramp control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBypass\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSignal Outputs\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eRUN and TOR (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e220 × 70 × 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cdiv style=\"padding:30px;\"\u003e\n\n\u003c!-- PRODUCT OVERVIEW --\u003e\n\u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003eThe \u003cstrong\u003eABB PSR105-600-70\u003c\/strong\u003e is a compact industrial motor softstarter from the \u003cstrong\u003eABB PSR Series\u003c\/strong\u003e. It provides a rated operational current of \u003cstrong\u003e105A (IEC)\u003c\/strong\u003e and supports \u003cstrong\u003e55kW three-phase motors at 400V\u003c\/strong\u003e under ABB's specified normal-start conditions. With a rated operational voltage of \u003cstrong\u003e208–600V AC\u003c\/strong\u003e and a \u003cstrong\u003e100–240V AC, 50\/60Hz\u003c\/strong\u003e control supply, the unit provides adjustable voltage-ramp soft starting and stopping. Its integrated bypass reduces losses during normal motor operation. Manufacturer order code: \u003cstrong\u003e1SFA896115R7000\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003c!-- KEY PRODUCT FEATURES --\u003e\n\u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n\u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eABB PSR Compact Series\u003c\/strong\u003e — Industrial motor soft starting and stopping.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e105A Rated Current\u003c\/strong\u003e — IEC in-line operational current rating.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e55kW at 400V\u003c\/strong\u003e — Rated motor power under normal-start conditions.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–600V AC\u003c\/strong\u003e — Rated main operational voltage range.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e100–240V Control Supply\u003c\/strong\u003e — 50\/60Hz AC control voltage.\u003c\/li\u003e\n\u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in Bypass\u003c\/strong\u003e — Reduces energy losses during normal running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Start and Stop\u003c\/strong\u003e — Three front potentiometers for voltage-ramp settings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n\u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n\u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n\u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Actual product photographs provided\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Product nameplate visibly shows PSR105-600-70\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e ABB order code 1SFA896115R7000 visible on product and packaging\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Actual packaging label photographed\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Verify exact model, electrical ratings and motor starting conditions before ordering\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c!-- AVAILABILITY --\u003e\n\u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003eIn Stock \u0026amp; Ready to Order\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003eABB \u003cstrong\u003ePSR105-600-70\u003c\/strong\u003e is currently listed as in stock at YingZhou. Actual product and packaging photos support model identification before purchase. Please confirm motor rated current, operating voltage, start duty and required external protection before installation.\u003c\/p\u003e\n\u003cp style=\"font-size:13px;color:#555;margin:12px 0 0;\"\u003e\u003cstrong\u003eInstallation Note:\u003c\/strong\u003e Select suitable upstream short-circuit protection and motor overload protection according to ABB's official installation and coordination instructions. The product packaging also contains a warning regarding upstream fuse protection.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c!-- CTA --\u003e\n\u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003eIN STOCK\u003c\/div\u003e\n\u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003eABB PSR105-600-70 | 105A Softstarter\u003c\/h3\u003e\n\u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e55kW at 400V | Built-in Bypass | Actual Product Photos. Order online or contact us for project and quantity pricing.\u003c\/p\u003e\n\u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Project Pricing\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c!-- ABB BRAND COLLECTION INTERNAL LINK --\u003e\n\u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other ABB industrial automation products?\u003c\/p\u003e\n\u003ca href=\"\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore ABB Industrial Automation Products\u003c\/a\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"PSR105-600-70","offer_id":51869250519343,"sku":"PSR105-600-70","price":642.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-PSR105-600-70-PSR-Series-105A-55kW-208-600V-AC-Compact-Softstarter-with-Built-in-Bypass.jpg?v=1792344577"},{"product_id":"schneider-ats480d62y-soft-starter","title":"Schneider Electric ATS480D62Y Altivar ATS480 62A 208-690V 30kW 400V Normal Duty Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric ATS480D62Y Altivar ATS480 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      62A Normal Duty | 208–690V AC | 3-Phase | 30kW at 400V\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FBF4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#278A39;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Exact Model: ATS480D62Y\n       |  Actual Packaging Photo\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FBF4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eATS480D62Y\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIndustrial Soft Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Destination\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAsynchronous Motors\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Phases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3-Phase\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–690V AC, -15% \/ +10%\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e110–230V AC, 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current - Normal Duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e62A at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current - Heavy Duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e47A at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 230V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e15kW Normal \/ 11kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 400V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e30kW Normal \/ 22kW Heavy, In-Line\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 440V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30kW Normal \/ 22kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 500V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e37kW Normal \/ 30kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 690V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45kW Normal \/ 37kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Technology\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTorque Control System (TCS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIntegrated Motor Overload Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eModbus Serial (RS-485)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOptional Communication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eModbus TCP, EtherNet\/IP, PROFINET, PROFIBUS DP, CANopen via Optional Modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBypass Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eExternal Bypass Control Supported\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e190 × 290 × 247 mm\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e8.3 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-15°C to +40°C Without Derating\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC 60947-4-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric ATS480D62Y\u003c\/strong\u003e is an\n      industrial soft starter from the\n      \u003cstrong\u003eAltivar Soft Starter ATS480\u003c\/strong\u003e series,\n      designed for three-phase asynchronous motors.\n\n      It provides a \u003cstrong\u003e62A normal-duty rating\u003c\/strong\u003e\n      and a \u003cstrong\u003e47A heavy-duty rating\u003c\/strong\u003e at 40°C,\n      with a \u003cstrong\u003e208–690V AC\u003c\/strong\u003e main power supply.\n\n      At \u003cstrong\u003e400V\u003c\/strong\u003e, the ATS480D62Y supports\n      \u003cstrong\u003e30kW normal-duty\u003c\/strong\u003e or\n      \u003cstrong\u003e22kW heavy-duty\u003c\/strong\u003e motor applications\n      with in-line connection.\n\n      Its torque-control technology, integrated motor\n      protection and built-in Modbus serial communication\n      support controlled industrial motor starting and stopping.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FBF4;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e62A\u003c\/strong\u003e normal-duty rated current at 40°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e47A\u003c\/strong\u003e heavy-duty rated current at 40°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–690V AC\u003c\/strong\u003e three-phase power supply\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e30kW at 400V\u003c\/strong\u003e normal-duty motor rating, in-line\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e110–230V AC\u003c\/strong\u003e control power supply\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTorque Control System\u003c\/strong\u003e for motor starting and stopping\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in Modbus Serial\u003c\/strong\u003e communication\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\u003cstrong\u003eIntegrated Motor Overload Protection\u003c\/strong\u003e\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExternal Bypass Control\u003c\/strong\u003e supported\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7EBDD;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Actual packaging photo\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Packaging model label visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          ATS480D62Y and electrical ratings shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Verify exact unit model\/nameplate before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#278A39;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eATS480D62Y\u003c\/strong\u003e is\n        currently in stock according to our inventory\n        information.\n\n        An actual packaging photograph showing the\n        exact model and electrical ratings is provided.\n\n        Please confirm the required quantity, exact\n        model configuration and shipping details\n        before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric ATS480D62Y\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#278A39;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/schneider\" style=\"color:#278A39;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"ATS480D62Y","offer_id":52066653798703,"sku":"ATS480D62Y","price":1014.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-ATS480D62Y-Altivar-ATS480-62A-208-690V-30kW-400V-Normal-Duty-Soft-Starter.jpg?v=1792345124"},{"product_id":"schneider-ats480d22y-soft-starter","title":"Schneider Electric ATS480D22Y Altivar ATS480 22A 208-690V 11kW 400V Normal Duty Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric ATS480D22Y Altivar ATS480 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      22A Normal Duty | 208–690V AC | 3-Phase | 11kW at 400V\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FBF4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#278A39;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Exact Model: ATS480D22Y\n       |  Actual Packaging Photo\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FBF4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eATS480D22Y\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIndustrial Soft Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Destination\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAsynchronous Motors\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Phases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3-Phase\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–690V AC, -15% \/ +10%\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e110–230V AC, 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current - Normal Duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e22A at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current - Heavy Duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e17A at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 230V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5.5kW Normal \/ 4kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 400V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e11kW Normal \/ 7.5kW Heavy, In-Line\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 500V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e11kW Normal \/ 9kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 690V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e18.5kW Normal \/ 15kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Technology\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTorque Control System (TCS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIntegrated Motor Overload Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eModbus Serial (RS-485)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOptional Communication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eModbus TCP, EtherNet\/IP, PROFINET, PROFIBUS DP, CANopen via Optional Modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBypass Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eExternal Bypass Control Supported\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e160 × 275 × 203 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4.9 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric ATS480D22Y\u003c\/strong\u003e is an\n      industrial soft starter from the\n      \u003cstrong\u003eAltivar Soft Starter ATS480\u003c\/strong\u003e series,\n      designed for three-phase asynchronous motors.\n\n      It provides a \u003cstrong\u003e22A normal-duty rating\u003c\/strong\u003e\n      and a \u003cstrong\u003e17A heavy-duty rating\u003c\/strong\u003e at 40°C,\n      with a \u003cstrong\u003e208–690V AC\u003c\/strong\u003e main power supply.\n\n      At \u003cstrong\u003e400V\u003c\/strong\u003e, the ATS480D22Y supports\n      \u003cstrong\u003e11kW normal-duty\u003c\/strong\u003e or\n      \u003cstrong\u003e7.5kW heavy-duty\u003c\/strong\u003e motor applications\n      with in-line connection.\n\n      Its torque-control technology, integrated motor\n      protection and built-in Modbus serial communication\n      support industrial motor starting and stopping.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FBF4;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e22A\u003c\/strong\u003e normal-duty rated current at 40°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e17A\u003c\/strong\u003e heavy-duty rated current at 40°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–690V AC\u003c\/strong\u003e three-phase power supply\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e11kW at 400V\u003c\/strong\u003e normal-duty motor rating, in-line\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e110–230V AC\u003c\/strong\u003e control power supply\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTorque Control System\u003c\/strong\u003e for motor starting and stopping\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in Modbus Serial\u003c\/strong\u003e communication\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\u003cstrong\u003eIntegrated Motor Overload Protection\u003c\/strong\u003e\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExternal Bypass Control\u003c\/strong\u003e supported\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7EBDD;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Actual packaging photo\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Packaging model label visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          ATS480D22Y and electrical ratings shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Verify exact unit model\/nameplate before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#278A39;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eATS480D22Y\u003c\/strong\u003e is\n        currently in stock according to our inventory\n        information.\n\n        An actual packaging photograph showing the\n        exact model and electrical rating is provided.\n\n        Please confirm the required quantity, exact\n        model configuration and shipping details\n        before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric ATS480D22Y\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#278A39;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/schneider\" style=\"color:#278A39;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"ATS480D22Y","offer_id":52066661237039,"sku":"ATS480D22Y","price":664.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-ATS480D22Y-Altivar-ATS480-22A-208-690V-11kW-400V-Normal-Duty-Soft-Starter.jpg?v=1792345131"},{"product_id":"schneider-ats480d32y-soft-starter","title":"Schneider Electric ATS480D32Y Altivar ATS480 32A 208-690V 15kW 400V Normal Duty Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric ATS480D32Y Altivar ATS480 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      32A Normal Duty | 208–690V AC | 3-Phase | 15kW at 400V\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FBF4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#278A39;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Exact Model: ATS480D32Y\n       |  Actual Packaging Photo\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FBF4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eATS480D32Y\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIndustrial Soft Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Destination\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAsynchronous Motors\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Phases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3-Phase\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–690V AC, -15% \/ +10%\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e110–230V AC, 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current - Normal Duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e32A at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current - Heavy Duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e22A at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 230V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e7.5kW Normal \/ 5.5kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 400V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e15kW Normal \/ 11kW Heavy, In-Line\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 500V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e18.5kW Normal \/ 11kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 690V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e22kW Normal \/ 18.5kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Technology\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTorque Control System (TCS)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIntegrated Motor Overload Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Thermal Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eClass 10E\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eModbus Serial (RS-485)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOptional Communication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eModbus TCP, EtherNet\/IP, PROFINET, PROFIBUS DP, CANopen via Optional Modules\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBypass Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eExternal Bypass Control Supported\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e160 × 275 × 203 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4.9 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC 60947-4-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric ATS480D32Y\u003c\/strong\u003e is an\n      industrial soft starter from the\n      \u003cstrong\u003eAltivar Soft Starter ATS480\u003c\/strong\u003e series,\n      designed for three-phase asynchronous motors.\n\n      It provides a \u003cstrong\u003e32A normal-duty rating\u003c\/strong\u003e\n      and a \u003cstrong\u003e22A heavy-duty rating\u003c\/strong\u003e at 40°C,\n      with a \u003cstrong\u003e208–690V AC\u003c\/strong\u003e main power supply.\n\n      At \u003cstrong\u003e400V\u003c\/strong\u003e, the ATS480D32Y supports\n      \u003cstrong\u003e15kW normal-duty\u003c\/strong\u003e or\n      \u003cstrong\u003e11kW heavy-duty\u003c\/strong\u003e motor applications\n      with in-line connection.\n\n      Its torque-control technology, integrated motor\n      protection and built-in Modbus serial communication\n      support controlled industrial motor starting and stopping.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FBF4;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e32A\u003c\/strong\u003e normal-duty rated current at 40°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e22A\u003c\/strong\u003e heavy-duty rated current at 40°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–690V AC\u003c\/strong\u003e three-phase power supply\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e15kW at 400V\u003c\/strong\u003e normal-duty motor rating, in-line\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e110–230V AC\u003c\/strong\u003e control power supply\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTorque Control System\u003c\/strong\u003e for motor starting and stopping\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in Modbus Serial\u003c\/strong\u003e communication\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\u003cstrong\u003eIntegrated Motor Overload Protection\u003c\/strong\u003e\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExternal Bypass Control\u003c\/strong\u003e supported\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7EBDD;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Actual packaging photo\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Packaging model label visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          ATS480D32Y and electrical ratings shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Verify exact unit model\/nameplate before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#278A39;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eATS480D32Y\u003c\/strong\u003e is\n        currently in stock according to our inventory\n        information.\n\n        An actual packaging photograph showing the\n        exact model and electrical ratings is provided.\n\n        Please confirm the required quantity, exact\n        model configuration and shipping details\n        before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric ATS480D32Y\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#278A39;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/schneider\" style=\"color:#278A39;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"ATS480D32Y","offer_id":52066745614639,"sku":"ATS480D32Y","price":727.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-ATS480D32Y-Altivar-ATS480-32A-208-690V-15kW-400V-Normal-Duty-Soft-Starter.jpg?v=1792345137"},{"product_id":"schneider-ats480d17y-17a-soft-starter","title":"Schneider ATS480D17Y Altistart 480 Soft Starter | 17A 7.5kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480D17Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480D17Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e17 A\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480D17Y is an advanced digital soft starter from the industry-trusted Altistart 480 platform. Engineered to optimize the starting and stopping characteristics of 3-phase asynchronous motors, this 17A controller provides seamless torque control across broad voltage networks from 208V to 690V, reducing mechanical stress, minimizing electrical shocks, and extending equipment operational longevity.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAltistart 480 Control:\u003c\/strong\u003e Incorporates advanced torque control algorithms to manage fluid hammer in pumps and mechanical stress in drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Operates efficiently across standard multi-voltage industrial infrastructure from 208V up to 690V.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's rigorous standards to guarantee maximum reliability and continuous uptime in harsh plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480D17Y","offer_id":54328238539055,"sku":"ATS480D17Y","price":520.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480D17Y-Altistart-480-Soft-Starter-17A-7_5kW-208-690V-Brand-New-Original.jpg?v=1786178196"},{"product_id":"schneider-ats480d47y-soft-starter","title":"Schneider Electric ATS480D47Y Altivar ATS480 47A 208-690V 22kW 400V 3-Phase Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric ATS480D47Y Altivar ATS480 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      47A Normal Duty | 208–690V AC | 3-Phase | 22kW at 400V\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FBF4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#278A39;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Exact Model: ATS480D47Y\n       |  Actual Packaging Photo\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FBF4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eATS480D47Y\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAltivar Soft Starter ATS480\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIndustrial Soft Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Destination\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAsynchronous Motors\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Phases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3-Phase\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–690V AC, -15% \/ +10%\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e110–230V AC, 50\/60Hz\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current - Normal Duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e47A at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Current - Heavy Duty\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e38A at 40°C\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 400V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e22kW Normal \/ 18.5kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power @ 690V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e37kW Normal \/ 30kW Heavy, In-Line\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTorque Control\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIntegrated Motor Overload Protection\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Thermal Protection\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eClass 10E\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCommunication Protocol\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eModbus RTU (RS-485)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOptional Communication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eModbus TCP, EtherNet\/IP, PROFINET, PROFIBUS DP, CANopen via Options\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBypass Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eExternal Bypass Control Supported\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e160 × 275 × 203 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4.9 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-15°C to +40°C Without Derating\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIEC 60947-4-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric ATS480D47Y\u003c\/strong\u003e is an\n      industrial soft starter from the \u003cstrong\u003eAltivar Soft\n      Starter ATS480\u003c\/strong\u003e range, designed for three-phase\n      asynchronous motors. It provides a\n      \u003cstrong\u003e47A normal-duty rating\u003c\/strong\u003e and a\n      \u003cstrong\u003e38A heavy-duty rating\u003c\/strong\u003e at 40°C, with a\n      \u003cstrong\u003e208–690V AC\u003c\/strong\u003e main supply range.\n\n      At \u003cstrong\u003e400V\u003c\/strong\u003e, the ATS480D47Y supports\n      \u003cstrong\u003e22kW normal-duty\u003c\/strong\u003e or\n      \u003cstrong\u003e18.5kW heavy-duty\u003c\/strong\u003e motor applications\n      with in-line connection. Its torque-control technology,\n      motor protection functions and built-in Modbus serial\n      communication support industrial motor-starting\n      and stopping requirements.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FBF4;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e47A\u003c\/strong\u003e normal-duty rated current at 40°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e38A\u003c\/strong\u003e heavy-duty rated current at 40°C\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–690V AC\u003c\/strong\u003e three-phase power supply\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e22kW at 400V\u003c\/strong\u003e normal-duty motor rating, in-line\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e110–230V AC\u003c\/strong\u003e control power supply\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTorque Control\u003c\/strong\u003e motor starting technology\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in Modbus RTU\u003c\/strong\u003e serial communication\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\u003cstrong\u003eIntegrated Motor Overload Protection\u003c\/strong\u003e\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eExternal Bypass Control\u003c\/strong\u003e supported\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7EBDD;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Actual packaging photo\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Packaging model label visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          ATS480D47Y and electrical ratings shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Verify exact unit model\/nameplate before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#278A39;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eATS480D47Y\u003c\/strong\u003e is currently\n        in stock according to our inventory information.\n        An actual packaging photograph showing the model\n        and electrical rating is provided.\n\n        Please confirm the required quantity, exact unit\n        configuration and shipping details before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric ATS480D47Y\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#278A39;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/schneider\" style=\"color:#278A39;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"ATS480D47Y","offer_id":54328312791343,"sku":"ATS480D47Y","price":885.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-ATS480D47Y-Altivar-ATS480-47A-208-690V-22kW-400V-3-Phase-Soft-Starter.jpg?v=1792346338"},{"product_id":"schneider-ats480d75y-75a-soft-starter","title":"Schneider ATS480D75Y Altistart 480 Soft Starter | 75A 37kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480D75Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480D75Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e75 A (37 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480D75Y is an advanced digital soft starter from the industry-trusted Altistart 480 platform. Engineered to optimize the starting and stopping characteristics of 3-phase asynchronous motors, this 75A (37kW) controller provides seamless torque control across broad voltage networks from 208V to 690V, reducing mechanical stress, minimizing electrical shocks, and extending equipment operational longevity.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAltistart 480 Control:\u003c\/strong\u003e Incorporates advanced torque control algorithms to manage fluid hammer in pumps and mechanical stress in drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Operates efficiently across standard multi-voltage industrial infrastructure from 208V up to 690V.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's rigorous standards to guarantee maximum reliability and continuous uptime in harsh plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480D75Y","offer_id":54329805898031,"sku":"ATS480D75Y","price":955.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480D75Y-Altistart-480-Soft-Starter-75A-37kW-208-690V-Brand-New-Original.jpg?v=1786178198"},{"product_id":"schneider-ats480d88y-88a-soft-starter","title":"Schneider ATS480D88Y Altistart 480 Soft Starter | 88A 45kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480D88Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480D88Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e88 A (45 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480D88Y is an advanced digital soft starter from the industry-trusted Altistart 480 platform. Engineered to optimize the starting and stopping characteristics of 3-phase asynchronous motors, this 88A (45kW) controller provides seamless torque control across broad voltage networks from 208V to 690V, reducing mechanical stress, minimizing electrical shocks, and extending equipment operational longevity.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAltistart 480 Control:\u003c\/strong\u003e Incorporates advanced torque control algorithms to manage fluid hammer in pumps and mechanical stress in drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Operates efficiently across standard multi-voltage industrial infrastructure from 208V up to 690V.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's rigorous standards to guarantee maximum reliability and continuous uptime in harsh plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480D88Y","offer_id":54329926254895,"sku":"ATS480D88Y","price":1053.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480D88Y-Altistart-480-Soft-Starter-88A-45kW-208-690V-Brand-New-Original.jpg?v=1786178199"},{"product_id":"schneider-ats480c11y-110a-soft-starter","title":"Schneider ATS480C11Y Altistart 480 Soft Starter | 110A 55kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C11Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C11Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e110 A (55 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C11Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 110A (55kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C11Y","offer_id":54330585645359,"sku":"ATS480C11Y","price":1144.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C11Y-Altistart-480-Soft-Starter-110A-55kW-208-690V-Brand-New-Original.jpg?v=1786178200"},{"product_id":"schneider-ats480c14y-140a-soft-starter","title":"Schneider ATS480C14Y Altistart 480 Soft Starter | 140A 75kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C14Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C14Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e140 A (75 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C14Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 140A (75kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C14Y","offer_id":54330889339183,"sku":"ATS480C14Y","price":1235.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C14Y-Altistart-480-Soft-Starter-140A-75kW-208-690V-Brand-New-Original.jpg?v=1786178201"},{"product_id":"schneider-ats480c17y-170a-soft-starter","title":"Schneider ATS480C17Y Altistart 480 Soft Starter | 170A 90kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C17Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C17Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e170 A (90 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C17Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 170A (90kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C17Y","offer_id":54331107180847,"sku":"ATS480C17Y","price":1430.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C17Y-Altistart-480-Soft-Starter-170A-90kW-208-690V-Brand-New-Original.jpg?v=1786178202"},{"product_id":"schneider-ats480c21y-210a-soft-starter","title":"Schneider ATS480C21Y Altistart 480 Soft Starter | 210A 110kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C21Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C21Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e210 A (110 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C21Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 210A (110kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C21Y","offer_id":54332108013871,"sku":"ATS480C21Y","price":1560.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C21Y-Altistart-480-Soft-Starter-210A-110kW-208-690V-Brand-New-Original.jpg?v=1786178203"},{"product_id":"schneider-ats480c25y-250a-soft-starter","title":"Schneider ATS480C25Y Altistart 480 Soft Starter | 250A 132kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C25Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C25Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e250 A (132 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C25Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 250A (132kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C25Y","offer_id":54332155887919,"sku":"ATS480C25Y","price":1690.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C25Y-Altistart-480-Soft-Starter-250A-132kW-208-690V-Brand-New-Original.jpg?v=1786178204"},{"product_id":"schneider-ats480c32y-320a-soft-starter","title":"Schneider ATS480C32Y Altistart 480 Soft Starter | 320A 160kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C32Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C32Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e320 A (160 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C32Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 320A (160kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C32Y","offer_id":54334422745391,"sku":"ATS480C32Y","price":1885.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C32Y-Altistart-480-Soft-Starter-320A-160kW-208-690V-Brand-New-Original.jpg?v=1786178205"},{"product_id":"schneider-ats480c41y-410a-soft-starter","title":"Schneider ATS480C41Y Altistart 480 Soft Starter | 410A 220kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C41Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C41Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e410 A (220 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C41Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 410A (220kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C41Y","offer_id":54334480220463,"sku":"ATS480C41Y","price":2275.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C41Y-Altistart-480-Soft-Starter-410A-220kW-208-690V-Brand-New-Original.jpg?v=1786178207"},{"product_id":"schneider-ats480c48y-480a-soft-starter","title":"Schneider ATS480C48Y Altistart 480 Soft Starter | 480A 250kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C48Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C48Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e480 A (250 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C48Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 480A (250kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C48Y","offer_id":54334560043311,"sku":"ATS480C48Y","price":2860.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C48Y-Altistart-480-Soft-Starter-480A-250kW-208-690V-Brand-New-Original.jpg?v=1786178208"},{"product_id":"schneider-ats480c59y-590a-soft-starter","title":"Schneider ATS480C59Y Altistart 480 Soft Starter | 590A 315kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C59Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C59Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e590 A (315 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C59Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 590A (315kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C59Y","offer_id":54334617518383,"sku":"ATS480C59Y","price":3965.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C59Y-Altistart-480-Soft-Starter-590A-315kW-208-690V-Brand-New-Original.jpg?v=1786178209"},{"product_id":"schneider-ats480c66y-660a-soft-starter","title":"Schneider ATS480C66Y Altistart 480 Soft Starter | 660A 355kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C66Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C66Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e660 A (355 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C66Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 660A (355kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C66Y","offer_id":54334691049775,"sku":"ATS480C66Y","price":4745.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C66Y-Altistart-480-Soft-Starter-660A-355kW-208-690V-Brand-New-Original.jpg?v=1786178210"},{"product_id":"schneider-ats480c79y-790a-soft-starter","title":"Schneider ATS480C79Y Altistart 480 Soft Starter | 790A 400kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480C79Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480C79Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e790 A (400 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480C79Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 790A (400kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480C79Y","offer_id":54334748786991,"sku":"ATS480C79Y","price":5590.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480C79Y-Altistart-480-Soft-Starter-790A-400kW-208-690V-Brand-New-Original.jpg?v=1786178211"},{"product_id":"schneider-ats480m10y-1000a-soft-starter","title":"Schneider ATS480M10Y Altistart 480 Soft Starter | 1000A 560kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480M10Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480M10Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e1000 A (560 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480M10Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 1000A (560kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480M10Y","offer_id":54334872518959,"sku":"ATS480M10Y","price":6695.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480M10Y-Altistart-480-Soft-Starter-1000A-560kW-208-690V-Brand-New-Original.jpg?v=1786178212"},{"product_id":"schneider-ats480m12y-1200a-soft-starter","title":"Schneider ATS480M12Y Altistart 480 Soft Starter | 1200A 710kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480M12Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480M12Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e1200 A (710 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ High-Power Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480M12Y is an ultra-reliable, heavy-duty digital soft starter from the industry-trusted Altistart 480 platform. Engineered to master the starting and stopping demands of massive 3-phase industrial motors, this 1200A (710kW) controller provides precision torque management across broad voltage networks from 208V to 690V, dramatically curbing heavy electrical stress, preventing mechanical shock, and safeguarding critical high-power machinery.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eHeavy-Duty Altistart 480 Control:\u003c\/strong\u003e Advanced torque algorithms smoothly manage immense fluid dynamics in large pumps and high inertial loads in heavy industrial drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Built to scale across extensive multi-voltage industrial power frameworks from 208V up to 690V AC.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's strict enterprise standards to guarantee absolute reliability and continuous uptime in harsh, demanding plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480M12Y","offer_id":54334960271663,"sku":"ATS480M12Y","price":9100.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480M12Y-Altistart-480-Soft-Starter-1200A-710kW-208-690V-Brand-New-Original.jpg?v=1786178213"},{"product_id":"schneider-ats480d38y-38a-soft-starter","title":"Schneider ATS480D38Y Altistart 480 Soft Starter | 38A 18.5kW | 208-690V | Brand New Original","description":"\u003cdiv style=\"width: 100%; max-width: 850px; margin: 20px auto; font-family: 'Inter', system-ui, sans-serif; color: #333; line-height: 1.6; border: 3px solid #00965E; border-radius: 12px; overflow: hidden; background: #ffffff; box-shadow: 0 4px 15px rgba(0,0,0,0.1);\"\u003e\n    \u003cdiv style=\"background: #00965E; padding: 25px 30px; color: #ffffff;\"\u003e\n        \u003cdiv style=\"font-size: 11px; font-weight: 700; letter-spacing: 1px; text-transform: uppercase; margin-bottom: 5px; opacity: 0.9; color: #ffffff;\"\u003eYingZhou Industrial | Technical Specification\u003c\/div\u003e\n        \u003ch1 style=\"margin: 0; font-size: clamp(20px, 5vw, 26px); font-weight: 800; color: #ffffff;\"\u003eSchneider ATS480D38Y\u003c\/h1\u003e\n    \u003c\/div\u003e\n    \n    \u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 14px; border: 1px solid #00965E;\"\u003e\n        \u003ctr style=\"background: #e6f4ed;\"\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"padding: 12px; border: 1px solid #00965E; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eModel \/ Part Number\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eATS480D38Y\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eSeries\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eAltistart 480 Soft Starter Series\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eRated Current\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e38 A (18.5 kW)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003ePower Supply Voltage\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003e3-Phase 208V to 690V AC (50\/60Hz)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E; font-weight: 700;\"\u003eDevice Type\u003c\/td\u003e\n            \u003ctd style=\"padding: 10px; border: 1px solid #00965E;\"\u003eDigital Soft Starter \/ Motor Controller\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/table\u003e\n\n    \u003cdiv style=\"padding: 30px;\"\u003e\n        \u003ch2 style=\"font-size: 18px; font-weight: 800; color: #00965E; margin-top: 0;\"\u003ePerformance Overview\u003c\/h2\u003e\n        \u003cp style=\"font-size: 14px; color: #555; line-height: 1.8;\"\u003e\n            The Schneider ATS480D38Y is an advanced digital soft starter from the industry-trusted Altistart 480 platform. Engineered to optimize the starting and stopping characteristics of 3-phase asynchronous motors, this 38A (18.5kW) controller provides seamless torque control across broad voltage networks from 208V to 690V, reducing mechanical stress, minimizing electrical shocks, and extending equipment operational longevity.\n        \u003c\/p\u003e\n\n        \u003cdiv style=\"background: #e6f4ed; border: 2px solid #00965E; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #00965E; font-weight: 800;\"\u003e🚀 Key Performance Benefits\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eAltistart 480 Control:\u003c\/strong\u003e Incorporates advanced torque control algorithms to manage fluid hammer in pumps and mechanical stress in drives.\u003c\/li\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWide Voltage Compatibility:\u003c\/strong\u003e Operates efficiently across standard multi-voltage industrial infrastructure from 208V up to 690V.\u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eIndustrial Resilience:\u003c\/strong\u003e Manufactured to Schneider's rigorous standards to guarantee maximum reliability and continuous uptime in harsh plant environments.\u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n\n        \u003cdiv style=\"background: #fdfdfd; border: 2px solid #eee; border-radius: 12px; padding: 25px; border-left: 10px solid #00965E; margin-top: 20px;\"\u003e\n            \u003ch3 style=\"margin-top: 0; font-size: 16px; color: #333; font-weight: 800;\"\u003e⚙️ YingZhou Industrial Automation Integration\u003c\/h3\u003e\n            \u003cul style=\"font-size: 14px; color: #555; padding-left: 20px; margin-bottom: 0;\"\u003e\n                \u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eBrand Series:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eExplore Schneider Altistart Soft Starters\u003c\/a\u003e\n                \u003c\/li\u003e\n                \u003cli\u003e\n\u003cstrong\u003eAutomation Solutions:\u003c\/strong\u003e \n                    \u003ca href=\"\/collections\/schneider\" style=\"color: #00965E; text-decoration: underline; font-weight: 700;\"\u003eView YingZhou Industrial Automation Solutions\u003c\/a\u003e\n                \u003c\/li\u003e\n            \u003c\/ul\u003e\n        \u003c\/div\u003e\n    \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider","offers":[{"title":"ATS480D38Y","offer_id":54335009063215,"sku":"ATS480D38Y","price":663.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-ATS480D38Y-Altistart-480-Soft-Starter-38A-18_5kW-208-690V-Brand-New-Original.jpg?v=1786178214"},{"product_id":"siemens-3rw5536-6ha14-sirius-high-performance-soft-starter","title":"Siemens 3RW5536-6HA14 SIRIUS 3RW55 90kW 171A Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #009999;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#009999;padding:26px 30px;color:#fff;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#fff;line-height:1.3;\"\u003e\n      Siemens 3RW5536-6HA14 SIRIUS 3RW55 Soft Starter\n    \u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;\"\u003e\n      90kW @ 400V | 171A | 200–480V AC | 110–250V AC Control | Screw Terminals\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2F7FC;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#009999;\"\u003e✓ IN STOCK \u0026amp; AVAILABLE TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Exact Model Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#F2F7FC;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eVerified Product Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSiemens AG\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCatalog Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RW5536-6HA14\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSIRIUS\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3RW55\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC Semiconductor Motor Soft Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Operating Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e200–480V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Supply Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree-Phase AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e171A at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power at 400V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e90kW\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e110–250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStopping Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50%, Fixed\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStart-Up Ramp Time\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0–360 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRamp-Down Time\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0–360 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Torque Setting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStopping Torque Setting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTorque Limitation Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20–200%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAdjustable Current Limitation\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e125–800%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eParameter Sets\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e480V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eImpulse Withstand Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePackaging Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e402 × 304 × 328mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eEAN \/ GTIN\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4047621040998\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCzech Republic\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eManufacturer Lifecycle\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePM300 — Active Product\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #009999;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSiemens 3RW5536-6HA14\u003c\/strong\u003e is a\n      \u003cstrong\u003eSIRIUS 3RW55 high-performance soft starter\u003c\/strong\u003e\n      designed for controlled starting and stopping of three-phase\n      AC motors. It is rated for a main operating voltage of\n      \u003cstrong\u003e200–480V AC\u003c\/strong\u003e, with a rated operational current\n      of \u003cstrong\u003e171A at 40°C\u003c\/strong\u003e and a motor power rating of\n      \u003cstrong\u003e90kW at 400V\u003c\/strong\u003e. The unit uses a separate\n      \u003cstrong\u003e110–250V AC control supply\u003c\/strong\u003e and\n      \u003cstrong\u003escrew terminal connections\u003c\/strong\u003e.\n      The Siemens SIRIUS 3RW55 soft starter provides adjustable\n      motor-starting parameters, including starting voltage,\n      starting and stopping ramp times, torque limitation and\n      current limitation. For this model, the starting voltage\n      adjustment range is \u003cstrong\u003e20–100%\u003c\/strong\u003e, while the\n      starting and stopping ramp times can be adjusted within\n      \u003cstrong\u003e0–360 seconds\u003c\/strong\u003e. Three parameter sets are\n      available for configuration.\n      The product is intended for industrial motor starting\n      applications where controlled acceleration and deceleration\n      are required. Its soft-starting functionality should not be\n      confused with variable-frequency speed control.\n      The supplied actual photographs show a Siemens unit marked\n      \u003cstrong\u003e3RW5536-6HA14\u003c\/strong\u003e and corresponding Siemens\n      packaging carrying the same catalog number. The labels\n      identify the product as a \u003cstrong\u003e171A soft starter\u003c\/strong\u003e\n      with \u003cstrong\u003e200–480V AC main voltage\u003c\/strong\u003e and\n      \u003cstrong\u003e110–250V AC control supply\u003c\/strong\u003e.\n      Before ordering, verify the motor rated current, operating\n      voltage, load starting requirements, control supply and\n      installation conditions against the Siemens technical\n      documentation.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2F7FC;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eSiemens SIRIUS 3RW55 Soft Starter\u003c\/strong\u003e — High-performance motor starting device for three-phase AC applications.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e171A Rated Operational Current\u003c\/strong\u003e — Manufacturer-specified rating at 40°C under the applicable operating conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e90kW Motor Power at 400V\u003c\/strong\u003e — Motor power rating for the specified voltage class.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e200–480V AC Main Operating Voltage\u003c\/strong\u003e — Designed for the specified three-phase motor supply range.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e110–250V AC Control Supply\u003c\/strong\u003e — Separate control supply for the electronic starter.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eAdjustable Motor Starting\u003c\/strong\u003e — Starting voltage from 20% to 100% and configurable ramp times.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTorque and Current Limitation\u003c\/strong\u003e — Adjustable motor starting parameters for supported operating conditions.\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eThree Parameter Sets\u003c\/strong\u003e — Supports different configured motor-starting settings.\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eActual Product Photography\u003c\/strong\u003e — Physical nameplate and original packaging show matching Siemens catalog numbers.\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7E5F2;border-radius:8px;background:#FAFCFE;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#009999;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e✓ Actual Siemens product nameplate and packaging photographs supplied\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging catalog number: \u003cstrong\u003e3RW5536-6HA14\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Physical device catalog number: \u003cstrong\u003e3RW5536-6HA14\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product family: \u003cstrong\u003eSIRIUS 3RW55\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Product type: \u003cstrong\u003eAC Semiconductor Motor Starter\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Main operating voltage: \u003cstrong\u003e200–480V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Rated operational current: \u003cstrong\u003e171A\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Control supply: \u003cstrong\u003e110–250V AC\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Connection type: \u003cstrong\u003eScrew Terminals\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging quantity: \u003cstrong\u003e1 piece\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging EAN: \u003cstrong\u003e4047621040998\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Country of manufacture: \u003cstrong\u003eCzech Republic\u003c\/strong\u003e\n\u003c\/div\u003e\n        \u003cdiv\u003e✓ Packaging and device catalog numbers match\u003c\/div\u003e\n        \u003cdiv\u003e✓ Verify motor current, voltage and starting duty before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #009999;border-left:8px solid #009999;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#009999;\"\u003eIn Stock \u0026amp; Available to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Siemens \u003cstrong\u003e3RW5536-6HA14\u003c\/strong\u003e is marked\n        \u003cstrong\u003ein stock\u003c\/strong\u003e based on the supplied inventory\n        information. This SIRIUS 3RW55 soft starter is rated for\n        \u003cstrong\u003e171A at 40°C\u003c\/strong\u003e, with\n        \u003cstrong\u003e200–480V AC main operating voltage\u003c\/strong\u003e and\n        \u003cstrong\u003e110–250V AC control supply\u003c\/strong\u003e.\n        Actual photographs of the Siemens product and corresponding\n        packaging are available for exact-model identification.\n        The packaging is marked \u003cstrong\u003eQty: 1\u003c\/strong\u003e.\n        Please confirm your motor ratings, starting requirements,\n        installation conditions and order quantity before purchase.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#009999;border-radius:8px;text-align:center;color:#fff;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#fff;font-size:20px;\"\u003eSiemens 3RW5536-6HA14\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#fff;\"\u003e\n        Contact us for exact-model verification, available\n        quantities, bulk procurement and Siemens SIRIUS soft\n        starter sourcing. Please confirm the 171A current rating,\n        200–480V motor supply and 110–250V AC control supply\n        before ordering.\n      \u003c\/p\u003e\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#fff;color:#009999;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Bulk Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- SIEMENS BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other Siemens industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/collections\/siemens\" style=\"color:#009999;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore Siemens Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"SIEMENS","offers":[{"title":"3RW5536-6HA14","offer_id":58015035392303,"sku":"3RW5536-6HA14","price":3571.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Siemens-3RW5536-6HA14-SIRIUS-3RW55-90kW-171A-Soft-Starter.jpg?v=1793001569"},{"product_id":"schneider-ats01n212qn-soft-starter","title":"Schneider Electric ATS01N212QN Altistart 01 12A 380-415V 5.5kW 3-Phase Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #3DCD58;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#3DCD58;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      Schneider Electric ATS01N212QN Altistart 01 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      12A | 380–415V AC | 3-Phase | 5.5kW\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#F2FBF4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#278A39;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Exact Model: ATS01N212QN\n       |  Actual Product Photos\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#F2FBF4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSchneider Electric\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eATS01N212QN\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSeries\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAltistart 01\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDevice Short Name\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eATS01\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eSoft Starter for Asynchronous Motor\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eNetwork Phases\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e3-Phase\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Supply Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e380–415V AC ±10%\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMotor Power\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e5.5kW at 380–415V, 3-Phase\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarter Rating (IcL)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e12A\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSupply Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz ±5%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eVoltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAdjustable 1–10 Seconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDeceleration Time\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAdjustable 1–10 Seconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntegrated Bypass\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUtilisation Category\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eAC-53B\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Circuit Supply\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eBuilt into the Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45 × 124 × 131 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInstallation\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eDIN Rail \/ Screw Fixing\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProtection Rating\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e-10°C to +40°C Without Derating\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eEN\/IEC 60947-4-2\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #3DCD58;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eSchneider Electric ATS01N212QN\u003c\/strong\u003e is a\n      compact soft starter from the \u003cstrong\u003eAltistart 01\u003c\/strong\u003e\n      series, designed for three-phase asynchronous motors.\n      It provides a \u003cstrong\u003e12A starter rating\u003c\/strong\u003e and supports\n      \u003cstrong\u003e5.5kW motors at 380–415V AC, 3-phase\u003c\/strong\u003e.\n      Its adjustable voltage-ramp starting and deceleration\n      functions help reduce mechanical stress during motor\n      starting and stopping. The integrated bypass and compact\n      design make it suitable for appropriately selected\n      motor-control applications.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#F2FBF4;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e12A\u003c\/strong\u003e rated soft starter current\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e5.5kW\u003c\/strong\u003e motor rating at 380–415V, 3-phase\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e380–415V AC\u003c\/strong\u003e rated supply voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eVoltage ramp\u003c\/strong\u003e motor starting method\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1–10 seconds\u003c\/strong\u003e adjustable starting time\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e1–10 seconds\u003c\/strong\u003e adjustable deceleration time\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eIntegrated bypass\u003c\/strong\u003e function\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003e45mm compact width\u003c\/strong\u003e with DIN-rail or screw fixing\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #D7EBDD;border-radius:8px;background:#FAFCFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#278A39;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Model\/nameplate visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#278A39;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003eATS01N212QN\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #3DCD58;border-left:8px solid #3DCD58;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#278A39;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        Schneider Electric \u003cstrong\u003eATS01N212QN\u003c\/strong\u003e is currently\n        in stock. Actual product and packaging photos are\n        available for exact-model verification.\n        Please confirm the required quantity and shipping\n        details before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#3DCD58;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        Schneider Electric ATS01N212QN\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#278A39;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- SCHNEIDER BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other Schneider Electric automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/schneider\" style=\"color:#278A39;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore Schneider Electric Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"Schneider","offers":[{"title":"ATS01N212QN","offer_id":58077554278703,"sku":"ATS01N212QN","price":190.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/Schneider-Electric-ATS01N212QN-Altistart-01-12A-380-415V-5_5kW-3-Phase-Soft-Starter.jpg?v=1792347197"},{"product_id":"products-abb-psr37-600-70-37a-600v-soft-starter","title":"ABB 1SFA896110R7000 PSR37-600-70 37A 18.5kW 400V 208-600V AC Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003eYingZhou Industrial Automation | Product Information\u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003eABB 1SFA896110R7000 PSR37-600-70 Soft Starter\u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e37A IEC | 18.5kW at 400V | 208–600V AC | 100–240V AC Control Supply | Built-In Bypass\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#C00000;\"\u003e✓ IN STOCK \u0026amp; READY TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Model \u0026amp; Packaging Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#FFF4F4;\"\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Order Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SFA896110R7000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003ePSR37-600-70\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR Softstarters\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR37\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCompact Soft Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current (Ie)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e37 A (IEC, In-Line)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL\/CSA Full Load Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e34 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Main Circuit Voltage (Ue)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Control Supply Voltage (Us)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e100–240 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 230 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e7.5 kW (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 400 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e18.5 kW (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 500 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e22 kW (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 208 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 240 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 480 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e25 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 600 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Starting Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTwo-Phase Controlled Voltage Ramp\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Stop Function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes — Voltage Ramp\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBuilt-In Bypass\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eYes — Integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard Starting Selection Basis\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 × Ie for 6 Seconds at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConfiguration Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree Potentiometers\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Ramp Time\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1–20 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStopping Ramp Time\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0–20 Seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInitial Voltage Setting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–70%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRun Signal Relay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes — Normally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTop of Ramp Signal Relay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes — Normally Open\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntegrated Electronic Motor Overload\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eNo — External Protection Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFieldbus Communication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOptional External Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCurrent Derating Above 40°C\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.8% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection — Main Terminals\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Dissipation — ABB NA eCatalog\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (H × W × D)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e187 × 54 × 153 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.00 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (Photo Verified)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003eProduct Overview\u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB 1SFA896110R7000\u003c\/strong\u003e, model \u003cstrong\u003ePSR37-600-70\u003c\/strong\u003e, is a \u003cstrong\u003ecompact soft starter\u003c\/strong\u003e from the \u003cstrong\u003eABB PSR Series\u003c\/strong\u003e. It features a \u003cstrong\u003e37 A IEC rated operational current\u003c\/strong\u003e, a \u003cstrong\u003e208–600 V AC main circuit voltage range\u003c\/strong\u003e, and a \u003cstrong\u003e100–240 V AC 50\/60 Hz control supply\u003c\/strong\u003e. The soft starter is rated for \u003cstrong\u003e18.5 kW motor power at 400 V\u003c\/strong\u003e under the manufacturer's specified operating conditions. It provides \u003cstrong\u003etwo-phase controlled soft starting and stopping through a voltage ramp\u003c\/strong\u003e, with \u003cstrong\u003eintegrated bypass\u003c\/strong\u003e and three potentiometers for adjustment. External motor overload and short-circuit protection must be selected separately according to the application.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e37 A IEC\u003c\/strong\u003e rated operational current for in-line connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e18.5 kW at 400 V\u003c\/strong\u003e rated motor power, with 7.5 kW at 230 V and 22 kW at 500 V\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e rated main circuit operating voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e100–240 V AC 50\/60 Hz\u003c\/strong\u003e control supply voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in bypass\u003c\/strong\u003e for reduced operating losses after starting\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTwo-phase controlled voltage ramp\u003c\/strong\u003e for adjustable soft start and stop\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eThree potentiometers\u003c\/strong\u003e for basic soft starter configuration\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Actual product photos\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Model\/nameplate visible\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Packaging shown\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Verify exact model \u003cstrong\u003ePSR37-600-70\u003c\/strong\u003e and order code \u003cstrong\u003e1SFA896110R7000\u003c\/strong\u003e before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003eIn Stock \u0026amp; Ready to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003e1SFA896110R7000\u003c\/strong\u003e, model \u003cstrong\u003ePSR37-600-70\u003c\/strong\u003e, is currently in stock. Actual product photos, soft starter nameplate details and packaging are available for exact-model verification. Please confirm the required \u003cstrong\u003e37 A motor current, 18.5 kW at 400 V motor rating, 208–600 V AC main circuit voltage\u003c\/strong\u003e, control supply voltage, starting duty and external motor protection requirements before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003eABB 1SFA896110R7000\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003eOrder online or contact us for project and quantity pricing.\u003c\/p\u003e\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Project Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other ABB industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore ABB Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"PSR37-600-70","offer_id":58083975594287,"sku":"PSR37-600-70","price":221.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-1SFA896110R7000-PSR37-600-70-37A-18_5kW-400V-208-600V-AC-Soft-Starter.jpg?v=1792347269"},{"product_id":"products-abb-psr85-600-70-85a-600v-soft-starter","title":"ABB 1SFA896114R7000 PSR85-600-70 85A 45kW 400V 208-600V AC Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003eYingZhou Industrial Automation | Product Information\u003c\/div\u003e\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003eABB 1SFA896114R7000 PSR85-600-70 Soft Starter\u003c\/h2\u003e\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e85A IEC | 45kW at 400V | 208–600V AC | 100–240V AC Control Supply | Built-In Bypass\u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#C00000;\"\u003e✓ IN STOCK \u0026amp; READY TO ORDER\u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e |  Actual Product Photos  |  Model \u0026amp; Packaging Verified\u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n    \u003ctr style=\"background:#FFF4F4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Order Code\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SFA896114R7000\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003ePSR85-600-70\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Range\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR Softstarters\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR85\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCompact Soft Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current (Ie)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e85 A (IEC, In-Line)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL\/CSA Full Load Current\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e80 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Main Circuit Voltage (Ue)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Control Supply Voltage (Us)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e100–240 V AC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Frequency\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 230 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e22 kW (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 400 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e45 kW (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 500 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e55 kW (IEC)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 208 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e25 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 240 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 480 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 600 V\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e75 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Starting Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTwo-Phase Controlled Voltage Ramp\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Stop Function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes — Voltage Ramp\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBuilt-In Bypass\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eYes — Integrated\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard Starting Selection Basis\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 × Ie for 6 Seconds at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConfiguration Method\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree Potentiometers\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInitial Voltage Setting\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–70%\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRun Signal Relay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTop of Ramp Signal Relay\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntegrated Electronic Motor Overload\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eNo — External Protection Required\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFieldbus Communication\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOptional External Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCurrent Derating Above 40°C\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.8% per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection — Main Circuit\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP10\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Dissipation — ABB NA eCatalog\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e7.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e70 × 220 × 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (Photo Verified)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003eProduct Overview\u003c\/h2\u003e\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB 1SFA896114R7000\u003c\/strong\u003e, model \u003cstrong\u003ePSR85-600-70\u003c\/strong\u003e,\n      is a \u003cstrong\u003ecompact soft starter\u003c\/strong\u003e from the \u003cstrong\u003eABB PSR Series\u003c\/strong\u003e.\n      It features an \u003cstrong\u003e85 A IEC rated operational current\u003c\/strong\u003e, a\n      \u003cstrong\u003e208–600 V AC main circuit voltage range\u003c\/strong\u003e, and a\n      \u003cstrong\u003e100–240 V AC 50\/60 Hz control supply\u003c\/strong\u003e. The soft starter is rated\n      for \u003cstrong\u003e45 kW motor power at 400 V\u003c\/strong\u003e under the manufacturer's specified\n      operating conditions. It provides \u003cstrong\u003etwo-phase controlled soft starting\n      and stopping through a voltage ramp\u003c\/strong\u003e, with \u003cstrong\u003eintegrated bypass\u003c\/strong\u003e\n      and three potentiometers for adjustment. External motor overload and short-circuit\n      protection must be selected separately according to the application.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eKey Product Features\u003c\/h3\u003e\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e85 A IEC\u003c\/strong\u003e rated operational current for in-line connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e45 kW at 400 V\u003c\/strong\u003e rated motor power, with 22 kW at 230 V and 55 kW at 500 V\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e rated main circuit operating voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e100–240 V AC 50\/60 Hz\u003c\/strong\u003e control supply voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in bypass\u003c\/strong\u003e for reduced operating losses after starting\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTwo-phase controlled voltage ramp\u003c\/strong\u003e for adjustable soft start and stop\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eThree potentiometers\u003c\/strong\u003e for basic soft starter configuration\u003c\/li\u003e\n      \u003c\/ul\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003eActual Product Verification\u003c\/h3\u003e\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Actual product photos\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Model\/nameplate visible\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Packaging shown\u003c\/div\u003e\n        \u003cdiv\u003e\n\u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e Verify exact model \u003cstrong\u003ePSR85-600-70\u003c\/strong\u003e and order code \u003cstrong\u003e1SFA896114R7000\u003c\/strong\u003e before ordering\u003c\/div\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003eIn Stock \u0026amp; Ready to Order\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003e1SFA896114R7000\u003c\/strong\u003e, model \u003cstrong\u003ePSR85-600-70\u003c\/strong\u003e,\n        is currently in stock. Actual product photos, soft starter nameplate details\n        and original packaging are available for exact-model verification.\n        Please confirm the required \u003cstrong\u003e85 A motor current, 45 kW at 400 V\n        motor rating, 208–600 V AC main circuit voltage\u003c\/strong\u003e,\n        control supply voltage, starting duty and external motor protection\n        requirements before ordering.\n      \u003c\/p\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003eIN STOCK\u003c\/div\u003e\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003eABB 1SFA896114R7000\u003c\/h3\u003e\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003eOrder online or contact us for project and quantity pricing.\u003c\/p\u003e\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003eRequest Project Pricing\u003c\/a\u003e\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003eLooking for other ABB industrial automation products?\u003c\/p\u003e\n      \u003ca href=\"\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003eExplore ABB Industrial Automation Products\u003c\/a\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"PSR85-600-70","offer_id":58084006035759,"sku":"PSR85-600-70","price":599.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-1SFA896114R7000-PSR85-600-70-85A-45kW-400V-208-600V-AC-Soft-Starter.jpg?v=1792347278"},{"product_id":"abb-psr30-600-70-softstarter-motor-control","title":"ABB 1SFA896109R7000 PSR30-600-70 30A 15kW 400V 208-600V AC Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      ABB 1SFA896109R7000 PSR30-600-70 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      30A IEC | 15kW at 400V | 208–600V AC | 100–240V AC Control Supply | Built-In Bypass\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#C00000;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Model \u0026amp; Packaging Verified\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#FFF4F4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Order Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SFA896109R7000\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003ePSR30-600-70\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR Softstarters\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR30\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCompact Soft Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current (Ie)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e30 A (IEC, In-Line)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL\/CSA Full Load Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e28 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Main Circuit Voltage (Ue)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Control Supply Voltage (Us)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e100–240 V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 230 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e7.5 kW (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 400 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e15 kW (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 500 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e18.5 kW (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 208 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e7.5 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 240 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e10 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 480 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 600 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e25 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Starting Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTwo-Phase Controlled Voltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Stop Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes — Voltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBuilt-In Bypass\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eYes — Integrated\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard Starting Selection Basis\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 × Ie for 6 Seconds at 40°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConfiguration Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree Potentiometers\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInitial Voltage Setting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–70%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRun Signal Relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTop of Ramp Signal Relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntegrated Electronic Motor Overload\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eNo — External Protection Required\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFieldbus Communication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOptional External Adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCurrent Derating Above 40°C\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.8% per °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection — Main Circuit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP20\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Power Loss at Rated Ie\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e36 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45 × 160 × 128 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (Photo Verified)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB 1SFA896109R7000\u003c\/strong\u003e,\n      model \u003cstrong\u003ePSR30-600-70\u003c\/strong\u003e,\n      is a \u003cstrong\u003ecompact soft starter\u003c\/strong\u003e\n      from the \u003cstrong\u003eABB PSR Series\u003c\/strong\u003e.\n      It features a \u003cstrong\u003e30 A IEC rated operational current\u003c\/strong\u003e,\n      a \u003cstrong\u003e208–600 V AC main circuit voltage range\u003c\/strong\u003e,\n      and a \u003cstrong\u003e100–240 V AC 50\/60 Hz control supply\u003c\/strong\u003e.\n      The soft starter is rated for\n      \u003cstrong\u003e15 kW motor power at 400 V\u003c\/strong\u003e\n      under the manufacturer's specified operating conditions.\n      It provides \u003cstrong\u003etwo-phase controlled soft starting\n      and stopping through a voltage ramp\u003c\/strong\u003e,\n      with \u003cstrong\u003eintegrated bypass\u003c\/strong\u003e\n      and three potentiometers for adjustment.\n      External motor overload and short-circuit protection\n      must be selected separately according to the application.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e30 A IEC\u003c\/strong\u003e rated operational current for in-line connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e15 kW at 400 V\u003c\/strong\u003e rated motor power, with 7.5 kW at 230 V and 18.5 kW at 500 V\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e rated main circuit operating voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e100–240 V AC 50\/60 Hz\u003c\/strong\u003e control supply voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in bypass\u003c\/strong\u003e for reduced operating losses after starting\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTwo-phase controlled voltage ramp\u003c\/strong\u003e for adjustable soft start and stop\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eThree potentiometers\u003c\/strong\u003e for basic soft starter configuration\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Model\/nameplate visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003ePSR30-600-70\u003c\/strong\u003e\n          and order code \u003cstrong\u003e1SFA896109R7000\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003e1SFA896109R7000\u003c\/strong\u003e,\n        model \u003cstrong\u003ePSR30-600-70\u003c\/strong\u003e,\n        is currently in stock.\n        Actual product photos, soft starter nameplate details\n        and original packaging are available for\n        exact-model verification.\n        Please confirm the required\n        \u003cstrong\u003e30 A motor current, 15 kW at 400 V\n        motor rating, 208–600 V AC main circuit voltage\u003c\/strong\u003e,\n        control supply voltage, starting duty and\n        external motor protection requirements before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        ABB 1SFA896109R7000\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other ABB industrial automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore ABB Industrial Automation Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"PSR30-600-70","offer_id":58095720923439,"sku":"PSR30-600-70","price":214.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-1SFA896109R7000-PSR30-600-70-30A-15kW-400V-208-600V-AC-Soft-Starter.jpg?v=1792347286"},{"product_id":"abb-psr72-600-70-soft-starter","title":"ABB 1SFA896113R7000 PSR72-600-70 72A 37kW 400V 208-600V AC Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      ABB 1SFA896113R7000 PSR72-600-70 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      72A IEC | 37kW at 400V | 208–600V AC | 100–240V AC Control Supply | Built-In Bypass\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#C00000;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Model \u0026amp; Packaging Verified\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#FFF4F4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Order Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SFA896113R7000\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003ePSR72-600-70\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR Softstarters\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR72\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCompact Soft Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current (Ie)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e72 A (IEC, In-Line)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL\/CSA Full Load Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e68 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Main Circuit Voltage (Ue)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Control Supply Voltage (Us)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e100–240 V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 230 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e22 kW (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 400 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e37 kW (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 500 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e45 kW (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 208 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 240 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e25 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 480 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 600 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e60 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Starting Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTwo-Phase Controlled Voltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Stop Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes — Voltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBuilt-In Bypass\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eYes — Integrated\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStandard Starting Selection Basis\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 × Ie for 6 Seconds at 40°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConfiguration Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree Potentiometers\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInitial Voltage Setting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–70%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRun Signal Relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTop of Ramp Signal Relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntegrated Electronic Motor Overload\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eNo — External Protection Required\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFieldbus Communication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOptional External Adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCurrent Derating Above 40°C\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.8% per °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection — Main Circuit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP10\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Dissipation — ABB NA eCatalog\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e5.2 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e70 × 220 × 180 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (Photo Verified)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB 1SFA896113R7000\u003c\/strong\u003e,\n      model \u003cstrong\u003ePSR72-600-70\u003c\/strong\u003e,\n      is a \u003cstrong\u003ecompact soft starter\u003c\/strong\u003e\n      from the \u003cstrong\u003eABB PSR Series\u003c\/strong\u003e.\n      It features a \u003cstrong\u003e72 A IEC rated operational current\u003c\/strong\u003e,\n      a \u003cstrong\u003e208–600 V AC main circuit voltage range\u003c\/strong\u003e,\n      and a \u003cstrong\u003e100–240 V AC 50\/60 Hz control supply\u003c\/strong\u003e.\n      The soft starter is rated for\n      \u003cstrong\u003e37 kW motor power at 400 V\u003c\/strong\u003e\n      under the manufacturer's specified operating conditions.\n      It provides \u003cstrong\u003etwo-phase controlled soft starting\n      and stopping through a voltage ramp\u003c\/strong\u003e,\n      with \u003cstrong\u003eintegrated bypass\u003c\/strong\u003e\n      and three potentiometers for adjustment.\n      External motor overload and short-circuit protection\n      must be selected separately according to the application.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e72 A IEC\u003c\/strong\u003e rated operational current for in-line connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e37 kW at 400 V\u003c\/strong\u003e rated motor power, with 22 kW at 230 V and 45 kW at 500 V\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e rated main circuit operating voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e100–240 V AC 50\/60 Hz\u003c\/strong\u003e control supply voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in bypass\u003c\/strong\u003e for reduced operating losses after starting\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTwo-phase controlled voltage ramp\u003c\/strong\u003e for adjustable soft start and stop\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eThree potentiometers\u003c\/strong\u003e for basic soft starter configuration\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Model\/nameplate visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003ePSR72-600-70\u003c\/strong\u003e\n          and order code \u003cstrong\u003e1SFA896113R7000\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003e1SFA896113R7000\u003c\/strong\u003e,\n        model \u003cstrong\u003ePSR72-600-70\u003c\/strong\u003e,\n        is currently in stock.\n        Actual product photos, soft starter nameplate details\n        and original packaging are available for\n        exact-model verification.\n        Please confirm the required\n        \u003cstrong\u003e72 A motor current, 37 kW at 400 V\n        motor rating, 208–600 V AC main circuit voltage\u003c\/strong\u003e,\n        control supply voltage, starting duty and\n        external motor protection requirements before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        ABB 1SFA896113R7000\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other ABB industrial automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore ABB Industrial Automation Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"PSR30-600-70","offer_id":58097946788143,"sku":"PSR30-600-70","price":438.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-1SFA896113R7000-PSR72-600-70-72A-37kW-400V-208-600V-AC-Soft-Starter.jpg?v=1792347396"},{"product_id":"abb-psr60-600-70-soft-starter","title":"ABB 1SFA896112R7000 PSR60-600-70 60A 30kW 400V 208-600V AC Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      ABB 1SFA896112R7000 PSR60-600-70 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      60A IEC | 30kW at 400V | 208–600V AC | 100–240V AC Control Supply | Built-In Bypass\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#C00000;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Model \u0026amp; Packaging Verified\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#FFF4F4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Order Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SFA896112R7000\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003ePSR60-600-70\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR Softstarters\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR60\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCompact Soft Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current (Ie)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e60 A (IEC, In-Line)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL\/CSA Full Load Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e59.4 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Main Circuit Voltage (Ue)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Control Supply Voltage (Us)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e100–240 V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 230 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e15 kW (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 400 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e30 kW (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 500 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e37 kW (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 208 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 240 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e20 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 480 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 600 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Starting Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTwo-Phase Controlled Voltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Stop Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes — Voltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBuilt-In Bypass\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eYes — Integrated\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Capacity at Rated Ie\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 × Ie for 6 Seconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConfiguration Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree Potentiometers\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInitial Voltage Setting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–70%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRun Signal Relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTop of Ramp Signal Relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntegrated Electronic Motor Overload\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eNo — External Protection Required\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFieldbus Communication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOptional External Adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCurrent Derating Above 40°C\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.8% per °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection — Main Circuit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP10\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003ePower Dissipation — ABB NA eCatalog\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e3.6 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e70 × 220 × 180 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (Photo Verified)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB 1SFA896112R7000\u003c\/strong\u003e,\n      model \u003cstrong\u003ePSR60-600-70\u003c\/strong\u003e,\n      is a \u003cstrong\u003ecompact soft starter\u003c\/strong\u003e\n      from the \u003cstrong\u003eABB PSR Series\u003c\/strong\u003e.\n      It features a \u003cstrong\u003e60 A IEC rated operational current\u003c\/strong\u003e,\n      a \u003cstrong\u003e208–600 V AC main circuit voltage range\u003c\/strong\u003e,\n      and a \u003cstrong\u003e100–240 V AC 50\/60 Hz control supply\u003c\/strong\u003e.\n      The soft starter is rated for\n      \u003cstrong\u003e30 kW motor power at 400 V\u003c\/strong\u003e\n      under the manufacturer's specified operating conditions.\n      It provides \u003cstrong\u003etwo-phase controlled soft starting\n      and stopping through a voltage ramp\u003c\/strong\u003e,\n      with \u003cstrong\u003eintegrated bypass\u003c\/strong\u003e\n      and three potentiometers for adjustment.\n      External motor overload and short-circuit protection\n      must be selected separately according to the application.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e60 A IEC\u003c\/strong\u003e rated operational current for in-line connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e30 kW at 400 V\u003c\/strong\u003e rated motor power, with 15 kW at 230 V and 37 kW at 500 V\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e rated main circuit operating voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e100–240 V AC 50\/60 Hz\u003c\/strong\u003e control supply voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in bypass\u003c\/strong\u003e for reduced operating losses after starting\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTwo-phase controlled voltage ramp\u003c\/strong\u003e for adjustable soft start and stop\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eThree potentiometers\u003c\/strong\u003e for basic soft starter configuration\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Model\/nameplate visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003ePSR60-600-70\u003c\/strong\u003e\n          and order code \u003cstrong\u003e1SFA896112R7000\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003e1SFA896112R7000\u003c\/strong\u003e,\n        model \u003cstrong\u003ePSR60-600-70\u003c\/strong\u003e,\n        is currently in stock.\n        Actual product photos, soft starter nameplate details\n        and original packaging are available for\n        exact-model verification.\n        Please confirm the required\n        \u003cstrong\u003e60 A motor current, 30 kW at 400 V\n        motor rating, 208–600 V AC main circuit voltage\u003c\/strong\u003e,\n        control supply voltage, starting duty and\n        external motor protection requirements before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        ABB 1SFA896112R7000\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other ABB industrial automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore ABB Industrial Automation Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"PSR60-600-70","offer_id":58098970886447,"sku":"PSR60-600-70","price":399.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-1SFA896112R7000-PSR60-600-70-60A-30kW-400V-208-600V-AC-Soft-Starter.jpg?v=1792347405"},{"product_id":"abb-psr45-600-70-soft-starter","title":"ABB 1SFA896111R7000 PSR45-600-70 45A 22kW 400V 208-600V AC Soft Starter","description":"\n\u003cdiv style=\"width:100%;max-width:850px;margin:20px auto;font-family:Inter,Arial,sans-serif;color:#222;line-height:1.65;border:2px solid #FF0000;border-radius:12px;overflow:hidden;background:#fff;box-shadow:0 4px 15px rgba(0,0,0,0.08);\"\u003e\n\n  \u003c!-- HERO --\u003e\n  \u003cdiv style=\"background:#FF0000;padding:26px 30px;color:#FFFFFF;\"\u003e\n    \u003cdiv style=\"font-size:11px;font-weight:800;letter-spacing:1px;text-transform:uppercase;margin-bottom:6px;color:#FFFFFF;\"\u003e\n      YingZhou Industrial Automation | Product Information\n    \u003c\/div\u003e\n\n    \u003ch2 style=\"margin:0;font-size:25px;font-weight:800;color:#FFFFFF;line-height:1.3;\"\u003e\n      ABB 1SFA896111R7000 PSR45-600-70 Soft Starter\n    \u003c\/h2\u003e\n\n    \u003cdiv style=\"margin-top:8px;font-size:14px;font-weight:700;color:#FFFFFF;\"\u003e\n      45A IEC | 22kW at 400V | 208–600V AC | 100–240V AC Control Supply | Built-In Bypass\n    \u003c\/div\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- STOCK STATUS --\u003e\n  \u003cdiv style=\"padding:14px 25px;background:#FFF4F4;border-bottom:1px solid #eee;font-size:14px;\"\u003e\n    \u003cstrong style=\"color:#C00000;\"\u003e\n      ✓ IN STOCK \u0026amp; READY TO ORDER\n    \u003c\/strong\u003e\n    \u003cspan style=\"color:#555;\"\u003e\n       |  Actual Product Photos\n       |  Model \u0026amp; Packaging Verified\n    \u003c\/span\u003e\n  \u003c\/div\u003e\n\n  \u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n  \u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\n    \u003ctr style=\"background:#FFF4F4;\"\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;width:40%;\"\u003eSpecification\u003c\/th\u003e\n      \u003cth style=\"padding:12px;border:1px solid #ddd;text-align:left;\"\u003eProduct Data\u003c\/th\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBrand\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eABB\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Order Code\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e1SFA896111R7000\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eExact Model\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003ePSR45-600-70\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Range\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR Softstarters\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Series\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003ePSR45\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eCompact Soft Starter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Operational Current (Ie)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e45 A (IEC, In-Line)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL\/CSA Full Load Current\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e46.2 A\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Main Circuit Voltage (Ue)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Control Supply Voltage (Us)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e100–240 V AC\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMain Circuit Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eControl Supply Frequency\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e50\/60 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 230 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e11 kW (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 400 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003e22 kW (IEC)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Motor Power at 500 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30 kW (IEC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 208 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e15 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 240 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e15 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 480 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e30 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eUL Motor Rating at 600 V\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40 HP\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRated Insulation Voltage (Ui)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e600 V\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Starting Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eTwo-Phase Controlled Voltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eSoft Stop Function\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes — Voltage Ramp\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eBuilt-In Bypass\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eYes — Integrated\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eStarting Capacity at Rated Ie\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e4 × Ie for 6 Seconds\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eConfiguration Method\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eThree Potentiometers\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eInitial Voltage Setting\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e40–70%\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eRun Signal Relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eTop of Ramp Signal Relay\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eIntegrated Electronic Motor Overload\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e\u003cstrong\u003eNo — External Protection Required\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eFieldbus Communication\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eOptional External Adapter\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eAmbient Operating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e−25°C to +60°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCurrent Derating Above 40°C\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e0.8% per °C\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDegree of Protection — Main Circuit\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eIP10\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eMaximum Power Loss at Rated Ie\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e8.1 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eDimensions (W × H × D)\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e54 × 187 × 153 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eProduct Net Weight\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003e1.0 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n    \u003ctr\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;font-weight:700;\"\u003eCountry of Manufacture\u003c\/td\u003e\n      \u003ctd style=\"padding:10px;border:1px solid #ddd;\"\u003eChina (Photo Verified)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\n  \u003c\/table\u003e\n\n  \u003cdiv style=\"padding:30px;\"\u003e\n\n    \u003c!-- PRODUCT OVERVIEW --\u003e\n    \u003ch2 style=\"font-size:19px;font-weight:800;color:#222;margin:0 0 12px;border-bottom:4px solid #FF0000;padding-bottom:7px;\"\u003e\n      Product Overview\n    \u003c\/h2\u003e\n\n    \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n      The \u003cstrong\u003eABB 1SFA896111R7000\u003c\/strong\u003e,\n      model \u003cstrong\u003ePSR45-600-70\u003c\/strong\u003e,\n      is a \u003cstrong\u003ecompact soft starter\u003c\/strong\u003e\n      from the \u003cstrong\u003eABB PSR Series\u003c\/strong\u003e.\n      It features a \u003cstrong\u003e45 A IEC rated operational current\u003c\/strong\u003e,\n      a \u003cstrong\u003e208–600 V AC main circuit voltage range\u003c\/strong\u003e,\n      and a \u003cstrong\u003e100–240 V AC 50\/60 Hz control supply\u003c\/strong\u003e.\n      The soft starter is rated for\n      \u003cstrong\u003e22 kW motor power at 400 V\u003c\/strong\u003e\n      under the manufacturer's specified operating conditions.\n      It provides \u003cstrong\u003etwo-phase controlled soft starting\n      and stopping through a voltage ramp\u003c\/strong\u003e,\n      with \u003cstrong\u003eintegrated bypass\u003c\/strong\u003e\n      and three potentiometers for adjustment.\n      External motor overload and short-circuit protection\n      must be selected separately according to the application.\n    \u003c\/p\u003e\n\n    \u003c!-- KEY PRODUCT FEATURES --\u003e\n    \u003cdiv style=\"background:#FFF4F4;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003e\n        Key Product Features\n      \u003c\/h3\u003e\n\n      \u003cul style=\"font-size:14px;color:#555;padding-left:20px;margin:0;\"\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e45 A IEC\u003c\/strong\u003e rated operational current for in-line connections\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e22 kW at 400 V\u003c\/strong\u003e rated motor power, with 11 kW at 230 V and 30 kW at 500 V\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e208–600 V AC\u003c\/strong\u003e rated main circuit operating voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003e100–240 V AC 50\/60 Hz\u003c\/strong\u003e control supply voltage\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eBuilt-in bypass\u003c\/strong\u003e for reduced operating losses after starting\u003c\/li\u003e\n        \u003cli style=\"margin-bottom:7px;\"\u003e\n\u003cstrong\u003eTwo-phase controlled voltage ramp\u003c\/strong\u003e for adjustable soft start and stop\u003c\/li\u003e\n        \u003cli\u003e\n\u003cstrong\u003eThree potentiometers\u003c\/strong\u003e for basic soft starter configuration\u003c\/li\u003e\n      \u003c\/ul\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ACTUAL PRODUCT VERIFICATION --\u003e\n    \u003cdiv style=\"margin-top:22px;padding:20px 22px;border:1px solid #F2D5D5;border-radius:8px;background:#FFFAFA;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 12px;color:#C00000;font-size:17px;\"\u003e\n        Actual Product Verification\n      \u003c\/h3\u003e\n\n      \u003cdiv style=\"font-size:14px;color:#555;line-height:1.9;\"\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Actual product photos\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Model\/nameplate visible\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Packaging shown\n        \u003c\/div\u003e\n\n        \u003cdiv\u003e\n          \u003cstrong style=\"color:#C00000;\"\u003e✓\u003c\/strong\u003e\n          Verify exact model \u003cstrong\u003ePSR45-600-70\u003c\/strong\u003e\n          and order code \u003cstrong\u003e1SFA896111R7000\u003c\/strong\u003e before ordering\n        \u003c\/div\u003e\n\n      \u003c\/div\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- AVAILABILITY --\u003e\n    \u003cdiv style=\"background:#fff;border:2px solid #FF0000;border-left:8px solid #FF0000;padding:22px;margin-top:22px;border-radius:8px;\"\u003e\n\n      \u003ch3 style=\"margin:0 0 8px;font-size:17px;color:#C00000;\"\u003e\n        In Stock \u0026amp; Ready to Order\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;color:#555;line-height:1.8;margin:0;\"\u003e\n        ABB \u003cstrong\u003e1SFA896111R7000\u003c\/strong\u003e,\n        model \u003cstrong\u003ePSR45-600-70\u003c\/strong\u003e,\n        is currently in stock.\n        Actual product photos, soft starter nameplate details\n        and original packaging are available for\n        exact-model verification.\n        Please confirm the required\n        \u003cstrong\u003e45 A motor current, 22 kW at 400 V\n        motor rating, 208–600 V AC main circuit voltage\u003c\/strong\u003e,\n        control supply voltage, starting duty and\n        external motor protection requirements before ordering.\n      \u003c\/p\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- CTA --\u003e\n    \u003cdiv style=\"margin-top:25px;padding:25px;background:#FF0000;border-radius:8px;text-align:center;color:#FFFFFF;\"\u003e\n\n      \u003cdiv style=\"font-size:12px;font-weight:800;color:#FFFFFF;\"\u003e\n        IN STOCK\n      \u003c\/div\u003e\n\n      \u003ch3 style=\"margin:8px 0;color:#FFFFFF;font-size:20px;\"\u003e\n        ABB 1SFA896111R7000\n      \u003c\/h3\u003e\n\n      \u003cp style=\"font-size:14px;margin:0 0 16px;color:#FFFFFF;\"\u003e\n        Order online or contact us for project and quantity pricing.\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/pages\/contact\" style=\"display:inline-block;background:#FFFFFF;color:#C00000;text-decoration:none;font-weight:800;padding:12px 24px;border-radius:6px;\"\u003e\n        Request Project Pricing\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n    \u003c!-- ABB BRAND INTERNAL LINK --\u003e\n    \u003cdiv style=\"margin-top:26px;padding-top:20px;border-top:1px solid #eee;\"\u003e\n\n      \u003cp style=\"margin:0 0 4px;font-size:14px;color:#555;\"\u003e\n        Looking for other ABB industrial automation products?\n      \u003c\/p\u003e\n\n      \u003ca href=\"\/collections\/abb\" style=\"color:#C00000;font-size:14px;font-weight:800;text-decoration:underline;\"\u003e\n        Explore ABB Industrial Automation Products\n      \u003c\/a\u003e\n\n    \u003c\/div\u003e\n\n  \u003c\/div\u003e\n\u003c\/div\u003e\n","brand":"ABB","offers":[{"title":"PSR45-600-70","offer_id":58099040059695,"sku":"PSR45-600-70","price":268.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0851\/9473\/5919\/files\/ABB-1SFA896111R7000-PSR45-600-70-45A-22kW-400V-208-600V-AC-Soft-Starter.jpg?v=1792347414"}],"url":"https:\/\/szyingzhou.com\/collections\/soft-starters.oembed","provider":"YingZhou Automatization","version":"1.0","type":"link"}